135 resultados para heavy metal stress


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is an all-superconducting-magnet electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged ion beams to meet the requirements of the Heavy Ion Research Facility in Lanzhou (HIRFL). To further enhance the performance of SECRAL, an aluminum chamber has been installed inside a 1.5 mm thick Ta liner used for the reduction of x-ray irradiation at the high voltage insulator. With double-frequency (18+14.5 GHz) heating and at maximum total microwave power of 2.0 kW, SECRAL has successfully produced quite a few very highly charged Xe ion beams, such as 10 e mu A of Xe37+, 1 e mu A of Xe43+, and 0.16 e mu A of Ne-like Xe44+. To further explore the capability of the SECRAL in the production of highly charged heavy metal ion beams, a first test run on bismuth has been carried out recently. The main goal is to produce an intense Bi31+ beam for HIRFL accelerator and to have a feel how well the SECRAL can do in the production of very highly charged Bi beams. During the test, though at microwave power less than 3 kW, more than 150 e mu A of Bi31+, 22 e mu A of Bi41+, and 1.5 e mu A of Bi50+ have been produced. All of these results have again demonstrated the great capability of the SECRAL source. This article will present the detailed results and brief discussions to the production of highly charged ion beams with SECRAL.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

本项工作利用多种分析手段(FTIR、TDS、RBS/C、AFM、SEM),对100keV He离子不同剂量(0.5,2.0,8.0×1016cm-2)注入的尖晶石中缺陷的形成及其对重金属原子的俘获效应进行了研究。在FTIR谱上观察到了Al-O键的共振吸收峰随剂量增加向小波数方向移动和随退火温度升高向大波数方向回复;随退火温度增加这三组样品的晶格损伤均经历先增大后减小的过程,但随剂量不同晶格损伤开始增加的温度不同;注入剂量为2.0×1016 cm-2样品在退火过程中其表面发生了形变,随剂量增加样品表面发现起皮现象。上述差异被认为是样品中不同缺陷的形成所引起的。随后,尝试了利用He离子注入形成的空位型缺陷俘获重金属原子的方法在尖晶石中合成金属纳米颗粒。吸收光谱上SPR吸收峰的出现,证实了金属纳米颗粒的形成

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0×10-6-1.0×10-1 M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline earth, transition and heavy metal ions, and minimal interference are caused by Li+, Na+, K+, Co2+, Hg2+, Ca2+, Pb2+ and Zn2+ ions, which are known to interfere with other chromium membrane sensors. The TTCT-based electrode shows a fast response time (15 s), and can be used in aqueous solutions of pH 3 - 5.5. The proposed sensor was used for the potentiometric titration of Cr3+ with EDTA and for a direct potentiometric determination of Cr3+ content in environmental samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The chelates formed between the heavy metal ion Pb(II) and the reagents 8-hydroxy-5-quinolinesulphonic acid, 8-hydroxy-7-quinolinesulphonic acid and 8-hydroxy-7-iodo-5-quinolinesulphonic acid exhibit strong room temperature phosphorescence (RTP) if retained on the surface of anion exchange resin beads. Based on the on-line formation, in a flow-injection system, of such RTP lead chelates and their transient immobilization on an anion exchange resin, three flow-through optosensing systems are investigated for lead in sea water. Optimum experimental conditions and the analytical performance characteristics of the three optosensors are discussed. Relative standard deviations (RSDs) of the order of 3% are typical at 100 ng ml−1 Pb(II) and the active sensing phases can easily be regenerated by passing 500 μl of 6 M hydrochloric acid. A lead(II) detection limit of 0.1 ng ml−1 (3×background SD, for 2 ml sample injection volumes) was achieved for the optosensor based on 8-hydroxy-7-quinolinesulphonic acid. Possible interferences present in sea water, including cations and anions which could affect the sensor response, are discussed in detail. Finally, the selected RTP flow-through optical sensor has been successfully tested for the determination of lead in sea water at a few ng ml−1.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article reports on the performance of a bismuth-coated carbon microdisk electrode (BiFμE) for the determination of trace heavy metals by anodic stripping voltammetry (ASV). The BiFμE was prepared by electrodeposition of a metallic bismuth film onto the microdisk, by applying an in-situ electroplating procedure. To test the performance of the BiFμE, ASV measurements were performed on synthetic solutions containing Cd2+, Pb2+, and Cu2+ as target ions. The results indicated that cadmium and lead gave well-defined ASV peaks with no interference, and their quantitative determination could be carried out straightforwardly. In particular, linear calibration curves over the range 5.0 x 10-8-1.0 x 10-6M for both ions, and detection limits of 7.8 and 2.9 nM, for cadmium and lead, respectively, after applying a 60 sec preconcentration step, were obtained. The reproducibility was also satisfactory, the relative standard deviation (RSD) being within 2.5% for both ions. Copper, instead, gave an ASV response that. in most experimental conditions, overlapped with that of bismuth. This circumstance made the determination of copper at the BiFμE difficult. Since the latter element could be detected reliably at the uncoated carbon microdisk electrode (CμE), both BiFμE and CμE were employed, respectively, for the determination of lead and copper ions in drinking water, wine, and tomato sauce.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

以黄土高原沟壑区的苹果园为研究对象,对6~36 a苹果园土壤重金属含量状况进行研究,结果发现,该区苹果园的高投入种植管理模式,能够影响重金属在土壤中的迁移与富集,使土壤重金属含量发生明显变化。土壤Cu含量随树龄增加而增加,20 a以上的土壤-果树系统对土壤Cu的输入与输出趋于平衡,Cu含量变化不大,且耕层土壤Cu含量较高。Cr含量随树龄线性递增,36 a果园0~20 cm,20~40 cm和40~60 cm土层Cr含量分别比6 a果园增加27.14%,17.09%和19.17%。Cd含量随树龄增加先增加后减少,长期大量施用磷肥是土壤Cd的主要来源,果园生态系统深层土壤Cd含量的峰值比耕层提前出现。Pb含量以15~26 a果园含量最高,树龄<15 a和>26 a时Pb含量较低。Hg含量则以15 a为转折点,在不同土层上呈现出不同的变化趋势。As含量在树龄<15 a时逐渐降低,15~20 a时逐渐增加,20 a以后果园土壤As含量趋于不变,且各土层之间差异不显著。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

研究黄土高原主要农田土壤重金属Cd的形态与生物有效性的关系,为评价本区土壤重金属Cd污染程度及其生物有效性提供一定的理论与数据依据。【方法】以黄土高原自北向南采集的12个0~20 cm耕层土壤为供试土样,通过室内分析和盆栽试验,研究了黄土高原石灰性土壤中不同形态Cd的分布特征及其生物有效性。【结果】黄土高原农田土壤Cd各形态总体分布特征为:有机结合态Cd、铁锰氧化物结合态Cd>碳酸盐结合态Cd>交换态Cd>残渣态Cd,自北向南各形态Cd含量均呈不同程度的增加趋势。各土壤类型间铁锰氧化物结合态Cd及碳酸盐结合态Cd平均含量均表现为:干润砂质新成土<黄土正常新成土<简育干润均腐土<土垫旱耕人为土,自北向南依次增加。碳酸盐结合态Cd和全Cd含量主要受到全氮、有效磷和砂粒含量的影响,且全氮和有效磷含量对其的影响为正效应。铁锰氧化物结合态Cd含量主要受全氮、有效磷、砂粒和粉砂粒含量的影响,且全氮、有效磷和粉砂粒含量对其的影响为正效应。土壤中各形态Cd含量与有机质、C/N、pH、CaCO3、粘粒含量的相关性均不显著,其中与C/N、pH、粘粒含量呈负相关。Cd在小麦茎叶层的含量小于根系;而作物不同部位Cd累积量表现...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, marine brown algae Laminaria japonica was chemically modified by crosslinking with epichlorohydrin (EC1 and EC2), or oxidizing by potassium permanganate (PC), or crosslinking with glutaraldehyde (GA), or only washed by distilled water (DW). They were used for equilibrium sorption uptake studies with Cd2+, Cu2+, Ni2+ and Zn2+.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, marine brown algae Laminaria japonica was chemically modified by crosslinking with epichlorohydrin (EC1 and EC2), or oxidizing by potassium permanganate (PC), or crosslinking with glutaraldehyde (GA), or only washed by distilled water (DW). They were used for equilibrium sorption uptake studies with Cd2+, Cu2+, Ni2+ and Zn2+. The experimental data have been analyzed using Langmuir, Freundlich and Redlich-Peterson isotherms. The results showed that the biosorption equilibrium was well described by both the Langmuir and Redlich-Peterson isotherms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrochemical measurement of respiratory chain activity is a rapid and reliable screening for the toxicity on microorganisms. Here, we investigated in-vitro effects of toxin on Escherichia coli (E. coli) that was taken as a model microorganism incubated with ferricyanide. The current signal of ferrocyanide effectively amplified by ultramicroelectrode array (UMEA), which was proven to be directly related to the toxicity. Accordingly, a direct toxicity assessment (DTA) based on chronoamperometry was proposed to detect the effect of toxic chemicals on microorganisms. The electrochemical responses to 3,5-dichlorophenol (DCP) under the incubation times revealed that the toxicity reached a stable level at 60 min, and its 50% inhibiting concentration (IC50) was estimated to be 8.0 mg L-1. At 60 min incubation, the IC50 values for KCN and As2O3 in water samples were 4.9 mg L-1 and 18.3 mg L-1, respectively. But the heavy metal ions, such as Cu2+ Pb2+ and Ni2+, showed no obvious toxicity on E. coli.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work herein reports the approach for the simultaneous determination of heavy metal ions including cadmium (Cd(II)), lead (Pb(II)), and chromium (Cr(VI)) using a bismuth film electrode (BFE) by anodic stripping voltammertry (ASV). The BFE used was plated in situ. Due to the reduction of Cr(VI) with H2O2 in the acid medium, on one hand, the Cr(III) was produced and Cr(VI) was indirectly detected by monitoring the content of Cr(III) using square-wave ASV. On the other hand, Pb(II) was also released from the complex between Pb(II) and Cr(VI). Furthermore, the coexistence of the Cd(II) was also simultaneously detected with Pb(II) and Cr(VI) in this system as a result of the formation of an alloy with Bi. The detection limits of this method were 1.39 ppb for Cd(II), 2.47 ppb for Pb(II) and 5.27 ppb for Cr(VI) with a preconcentration time of 120 s under optimal conditions (S/N = 3), respectively. Furthermore, the sensitivity of this method can be improved by controlling the deposition time or by using a cation-exchange polymer (such as Nafion) modified electrode.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ordered N-methylimidazolium functionalized mesoporous silica (SBA-15) anion exchangers were directly synthesized by co-condensation of tetraethoxysilane with 1-methyl-3(triethoxysilylpropyl)imidazolium chloride. The prepared samples with rod-like morphology showed high surface areas (> 400 m(2) g(-1)), well-ordered pores (> 58 angstrom), and excellent thermal stability up to 387 degrees C. The adsorption behaviors of Cr(VI) from aqueous solution on the anion exchangers were studied using the batch method. The anion exchangers had high adsorption capacity ranging from 50.8 to 90.5 mg g(-1), over a wider pH range (1-8) than amino functionalized mesoporous silica. The adsorption rate was fast, and the maximum adsorption was obtained at pH 4.6. The adsorption data for the anion exchangers were consistent with the Langmuir isotherm equation. Most active sites of the anion exchangers were easily accessible. The mixed solution of 0.1 mol L-1 NH3 center dot H2O and 0.5 mol L-1 NH4Cl was effective desorption solution, and 95% of Cr(VI) could be desorbed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel type of biochemical oxygen demand (BOD) biosensor was developed for water monitor, based on co-immobilizing of Trichosporon cutaneum and Bacillus subtilis in the sol-gel derived composite material which is composed of silica and the grafting copolymer of poly (vinyl alcohol) and 4-vinylpyridine (PVA-g-P(4-VP)). Factors that influence the performance of the resulting biosensor were examined. The biodegradable substrate spectrum could be expanded by the co-immobilized microorganisms. The biosensor prepared also exhibited good reproducibility and long-term stability. Good agreement was obtained between the results of the sensor BOD measurement and those obtained from conventional BOD5 method for water samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Monotopic membrane proteins are membrane proteins that interact with only one leaflet of the lipid bilayer and do not possess transmembrane spanning segments. They are endowed with important physiological functions but until now only few of them have been studied. Here we present a detailed biochemical, enzymatic and crystallographic characterization of the monotopic membrane protein sulfide:quinone oxidoreductase. Sulfide:quinone oxidoreductase is a ubiquitous enzyme involved in sulfide detoxification, in sulfide-dependent respiration and photosynthesis, and in heavy metal tolerance. It may also play a crucial role in mammals, including humans, because sulfide acts as a neurotransmitter in these organisms. We isolated and purified sulfide:quinone oxidoreductase from the native membranes of the hyperthermophilic bacterium Aquifex aeolicus. We studied the pure and solubilized enzyme by denaturing and non-denaturing polyacrylamide electrophoresis, size-exclusion chromatography, cross-linking, analytical ultracentrifugation, visible and ultraviolet spectroscopy, mass spectrometry and electron microscopy. Additionally, we report the characterization of its enzymatic activity before and after crystallization. Finally, we discuss the crystallization of sulfide:quinone oxidoreductase in respect to its membrane topology and we propose a classification of monotopic membrane protein crystal lattices. Our data support and complement an earlier description of the three-dimensional structure of A. aeolicus sulfide:quinone oxidoreductase (M. Marcia, U. Ermler, G. Peng, H. Michel, Proc Natl Acad Sci USA, 106 (2009) 9625-9630) and may serve as a reference for further studies on monotopic membrane proteins. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ferritin, the iron storage protein, plays a key role in iron metabolism. A cDNA encoding ferritin (FcFer) was cloned from hepatopancreas of Chinese shrimp, Fenneropenaeus chinensis. The predicted protein contains 170 amino acid residues with a predicted molecular weight (MW) about 19, 422.89 Da and theoretical isoelectric point (PI) of 4.73. Amino acid alignment of FcFer revealed 97% homology with Litopenaeus vannamei ferritin. Results of the RT-PCR showed that the expression of FcFer mRNA was up-regulated after shrimp was challenged with either white spot syndrome virus (WSSV) or heavy metal ions (Zn2+ and Cu2+) in the laboratory. A fusion protein containing FcFer was produced and the purified recombinant protein exhibited similar function of iron uptake in vitro. The result of in-gel digestion and identification using LC-ESI-MS showed that two peptide fragments (-DDVALPGFAK- and -LLEDEYLEEQVDS1KK-) of the recombinant protein were identical to the corresponding sequence of L. vannamei ferritin. The recombinant FcFer protein will be proved useful for study on the structure and function of ferritin in F chinensis. (c) 2006 Elsevier B.V. All rights reserved.