133 resultados para fetal membranes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The preparation and characteristics of bilayer lipid membranes including conventional bilayer membrane, solid supported self-assembling bilayer lipid membrane, solid supported hybrid bilayer membrane are described in this paper, The applications of bilayer lipid membranes in electrochemical biosensors are reviewed and the future development of electrochemical biosensor based on bilayer lipid membranes is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of swelling and stripping acidity on the mass transfer coefficient based on water phase and the inner diameters of membranes were studied with P507-HCl-Sm as working system in the two different kinds of hollow fiber membranes. Effects of extractant concentration, H+ concentration in aqueous phase and Sm3+ concentration on extraction rate were discussed and the corresponding reaction series were obtained. According to the investigations on the interfacial kinetics, the reaction kinetics equation and reaction rate constant were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid bilayer membrane consisting of self-assembled alkanethiol and lipid monolayer on gold electrode was fabricated by the paint - freeze method. The interaction of a kind of polyanion, K7Fe3+P2W17O62H2 with such bilayer membrane was investigated by cyclic voltammetry and ac impedance. The hybrid bilayer membrane on the gold electrode showed remarkable insulating property, however, the property was lessened to some extent after interaction with the polyanion. It was found the process was in-eversible. It is presumed that the interaction between the polyanion and lipid is an interaction of K7Fe3+P2W17O62H2 with the polar head group of PC, which lessens the interaction among PC polar head groups. The resulting molecular arrangement becomes looser, even some pores are produced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The permeation behavior of water vapor, H-2, CO2, O-2, N-2, and CH4 gases in a series of novel poly(aryl ether sulfone)s has been examined over a temperature range of 30-100 degreesC. These polymers include four alkyl-substituted cardo poly(aryl ether sulfone)s and four intermolecular interaction enhanced poly(aryl ether sulfone)s. Their water vapor and gas transport properties were compared to the unmodified cardo poly(aryl ether sulfone) (PES-C). It was found that the bulky alkyl substituents on the phenylene rings were advantageous for gas permeability, while the intermolecular hydrogen bonds and ionic bonds resulted in a considerable increase in gas permselectivity. The causes of the trend were interpreted according to free volume, interchain distance, and glass transition temperature, together with the respective contribution of gas solubility and diffusivity to the overall permeability. Of interest was the observation that IMPES-L, which simultaneously bears bulky isopropyl substituent and pendant carboxylic groups, displayed 377% higher O-2 permeability and 5.3% higher O-2/N-2 permselectivity than PES-C. Furthermore, sodium salt form PES-Na+ and potassium salt form PES-K+ exhibited water vapor permeability twice as high as PES-C and H2O/N-2 selectivity in 10(5) order of magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a kind of supported bilayer lipid membranes, hybrid bilayer membrane (HBM) was applied to the interaction between Ca2+ and lipid for the first time. By using Fe(CN)(6)(3-) as a probe, we found that Ca2+ could induce the ion channel of HBM to be in open state. STM images study proved this phenomenon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A kind of solid substrate, glassy carbon (GC) electrode. was selected to support self-assembled lipid layer membranes. On the surface of GC electrode. we made layers of dimyristoylphosphatidylcholine (DMPG, a kind of lipid). From electrochemical impedance experiments. we demonstrated that the lipid layers on the GC electrode were bilayer lipid membranes. We immobilized horseradish peroxidase (HRP) into the supported bilayer lipid membranes (s-BLM) to develop a kind of mediator-free biosensor for H2O2. The biosensor exhibited fine electrochemical response, stability and reproducibility due to the presence of the s-BLM. As a model of biological membrane, s-BLM could supply a biological environment for enzyme and maintain its activity. So s-BLM is an ideal choice to immobilize enzyme for constructing the mediator-free biosensor based on GC electrode. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gramicidin within the lipid bilayer matrix is a well-known channel-forming polypeptide, but the mechanism of the ions across the membrane induced by gramicidin is not well understood. We found that at very low concentration of gramicidin in a bilayer lipid membrane, the channel behavior was controlled by the voltage applied across the membrane. When the voltage is higher than 75 mV, the channel is closing, while lower than 75 mV, the channel is opening. But when the concentration of the gramicidin in the BLMs is high, the channel behavior is changed into voltage-independent. (C) 1998 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of La3+ on the structure and function of human erythrocyte membranes were investigated by fluorescence polarization, spin-labeled electron spin resonance (ESR) and differential scanning calorimetry (DSC). The results showed that increasing concentrations of La3+ inhibited (Na++K+)-ATPase and Mg2+-ATPase activities. La3+ lowered the lipid fluidity of erythrocyte membranes and induced structural transitions in erythrocyte membranes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new series of mixed conducting oxides, Sr10-n/2BinFe20Om (n = 4, 6, 8, 10), were synthesized by a solid state reaction method, and they have high oxygen permeability. The oxygen permeation rate at 1150 K is 0.41 ml(STD)/ cm(2).min for n = 6 and 0.90 ml(STD)/cm(2).min for n = 10, which is two times higher than that for Sr1-xBixFeO3 (x = 0.5). For the Sr1-xBixFeO3 (x = 0.1, 0.3, 0.5) series, the oxygen flux increases with increasing Bi content. (C) 1998 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The voltammetric behaviour of dye-modified supported bilayer lipid membranes is investigated. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the TCNQ-modified BLM, the voltammetric response is different due to the different methods used to prepare the membrane forming solution. The direct and indirect dissolved methods result in irreversible and reversible responses respectively. These results can be explained by the different styles of the orientation of TCNQ in the membrane. The reversible response is controlled by the diffusion of electroactive species in the interior of the membrane. When MB is used to modify the BLM, very complex voltammograms are obtained. The intersection of the voltammetric curves can be regarded to be owing to the appearance of new phase in the membrane caused by MB. But it disappears at lower scan rate. Peak current increases with decreasing scan rate. This indicates that the resistance of the membrane at lower scan rate is lower than that at higher scan rate. Asymmetric curve of MB incorporated BLM is ascribed to the different rates of redox reaction at the two membrane/solution interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supported lipid membranes consisting of self-assembled alkanethiol and lipid monolayers on gold substrates could be produced by three different deposition methods: the Langmuir-Blodgett (L-B) technique, the painted method, and the paint-freeze method, By using cyclic voltammetry, chronoamperometry/chronocoulometry and a.c. impedance measurements, we demonstrated that lipid membranes prepared by these three deposition methods had obvious differences in specific capacitance, resistance and thickness. The specific capacitance of lipid membranes prepared by depositing an L-B monolayer on the alkanethiol alkylated surfaces was 0.53 mu Fcm(-2), 0.44 mu Fcm(-2) by the painted method and 0.68 mu Fcm(-2) by the paint-freeze method. The specific conductivity of lipid membranes prepared by the L-B method was over three times lower than that of the painted lipid membranes, while that of the paint-freeze method was the lowest. The difference among the three types of lipid membranes was ascribed to the influence of the organic solvent in lipid films and the changes in density of the films. The lipid membranes prepared by the usual painted method contained a trace amount of the organic solvent. The organic solvent existing in the hydrocarbon core of the membrane reduced the density of the membrane and increased the thickness of the membrane. The membrane prepared by depositing an L-B monolayer containing no solvent had higher density and the lowest fluidity, and the thickness of the membrane was smaller. The lipid membrane prepared by the paint-freeze method changed its structure sharply at the lower temperature. The organic solvent was frozen out of the membrane while the density of the membrane increased greatly. All these caused the membrane to exist in a ''tilted'' state and the thickness of this membrane was the smallest. The lipid membrane produced by the paint-freeze method was a membrane not containing organic solvent. This method was easier in manipulation and had better reproducibility than that of the usual painting method and the method of forming free-standing lipid film. The solvent-free membrane had a long lifetime and a higher mechanical stability. This model membrane would be useful in many areas of scientific research.