173 resultados para Sensor output
Resumo:
The basic principle and critical characteristics of unattended ground sensors (UGS) based on fiber optic disk accelerometers are introduced. Mechanical principles of fiber optic disk accelerometers (FODA) and calculation methods are presented. An FODA with a high sensitivity of 120rad/g and a resonance frequency of 300Hz is designed and used for detection in military affair.
Resumo:
A Very-Small-Aperture Laser with a 250 X 500 nm(2) aperture has been created on a 650nm edge emitting LD. The highest far-field output power is 1.9mW and the power per unit emission area is about 15 MW/mu m(2). The special fabrication process and high output power mechanism are demonstrated respectively. The near-field distribution properties are also analyzed theoretically and experimentally.
Resumo:
The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, based on ICA, we propose a method for on-line verification of the phase difference of the current sensor. However, not all source components are mutually independent in our application. In order to get an exact result, we have proposed a relative likelihood index to choose an optimal result from different runs. The index is based on the maximum likelihood evaluation theory and the independent subspace analysis. The feasibility of our method has been confirmed by experimental results.
Resumo:
An enhanced technique for interrogating fiber Bragg grating wavelength shift using cascade wavelength division multiplexer (WDM) couplers was proposed and demonstrated. Three WDM couplers which show a linear filter function over the expected wavelength range are employed and cascaded to track Bragg wavelength shifts. Compared with single WDM demodulator. sharper spectral slope is obtained and considerable linear filter range is kept. The static and dynamic strain sensor demodulation experiments demonstrated that the simple passive technique improves the sensitivity approximately two times and keeps 5nm linear demodulation range based on our devices. The cascade WDM coupler demodulation system has high scan rate which can be used to monitor fast vibration.
Resumo:
In this paper, a low-complexity soft-output QRD-M detection algorithm is proposed for high-throughput Multiple-input multiple-output (MIMO) systems. By employing novel expansion on demand and distributed sorting scheme, the proposed algorithm can reduce 70% and 85% foundational operations for 16-QAM and 64-QAM respectively compared to the conventional QRD-M algorithm. Furthermore, the proposed algorithm can yield soft information to improve the bit error rate (BER) performance. Simulation results show that the proposed algorithm can achieve a near-NIL detection performance with less foundational operations
Resumo:
InGaAsP-InP square microlasers with a vertex output waveguide are fabricated by planar processes, and the etched sidewalls of the lasers are confined by insulating layer SiO2 and p-electrode TiAu metals. For a square microlaser with a side length of 30 mu m and a 2-mu m-wide output waveguide, a continuous-wave threshold current is 26 mA at room temperature and output power is 0.72 mW at 86 mA. The mode interval of 21 and 7.4 nm is observed for the microlasers with the side length of 10 and 30 mu m, respectively. Finite-difference time-domain (FDTD) simulations indicate that the lasing modes have incident angles of about 45 degrees at the boundaries of the resonator. In addition, square resonators surrounded by air, SiO2-Ti-Au, and SiO2-Au are compared by FDTD simulations.