136 resultados para Scatter plot


Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用田间小区试验研究了不同土壤水分条件下N肥对根系生长(根长、根重和根冠比)的影响。结果表明,玉米拔节期和开花期无论水分条件如何,施N肥可增加其总根长、表层根长和根重并使根冠比下降;灌浆期施N肥可增加总根长和表层根长,但正常水分条件下N肥使根重和根冠比下降,而干旱条件下N肥对根重和根冠比则无影响。不同处理根冠比大小与N吸收和分配有很大关系。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

以区域水土流失为主题 ,分析并阐述了该领域的研究现状 ,指出了当前存在的主要问题 ,并对研究的今后发展方向进行了展望。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用田间小区试验研究了不同灌水对冬小麦旗叶光合功能衰退的影响。研究表明 :小麦旗叶光合衰退初期引起光合下降的原因主要是气孔限制 ,后期则为非气孔限制。灌水可提高旗叶光合速率 ,并使由气孔限制向非气孔转变的时间推后 ,同时 ,还可增加叶绿素含量 ,增强根活力 ,使小麦旗叶光合功能持续期延长。过量灌水改善旗叶光合衰退的效果主要表现在后期 ,对产量提高的意义并不大。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

通过野外全坡长侵蚀小区试验,证明了稀土元素示踪法在土壤侵蚀垂直分布研究中的可应用性。结果表明该径流小区产沙强度坡长存在三种变化模式:增长型,增长 递减型和波动型,其形成机理可能与径流过程有关。利用稀土元素在坡面的再分析,初步建立了估算坡面沟蚀率的关系式。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

应用离心机法测定土壤水分特征,研究黄土高原典型草原带退耕地植被恢复演替过程中土壤持水性能的变化特点及趋势。结果表明:土壤含水量与土壤水吸力之间符合幂函数θ=aSb,参数a的变化随着植被的演替呈增加趋势;由于植被的影响,在同一吸力范围内的土壤含水量不同,植被为顶级长芒草(Stipabungeana)群落时,土壤在各吸力段的含水量最高,坡耕地最低;其它群落土壤含水量随着水吸力的增加变化趋于一致;退耕地植被在演替过程中通过提高土壤有机质含量改善结构,降低容重并增加毛管孔隙度,对土壤的储水和持水性能产生作用。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of the concentration of a nucleating agent (NA), namely 1,3:2,4-di(3,4-dimethylbenzylidene) sorbitol (DMDBS), on the gamma phase content in a propylene/ethylene copolymer was investigated by means of Differential Scanning Calorimetry (DSC), Wide-Angle X-ray Diffraction (WAXD), Small- Angle X-ray Scatter (SAXS) and Polarized Optical Microscopy (POM).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single-walled carbon nanohorn (SWCNH) was developed as new adsorbent for solid-phase extraction using 4-nitrophenol as representative. The unique exoteric structures and high surface area of SWCNH allow extracting a large amount of 4-nitrophenol over a short time. Highly sensitive determination of 4-nitrophenol was achieved by linear sweep voltammetry after only 120 s extraction. The calibration plot for 4-nitrophenol determination is linear in the range of 5.0 x 10(-8) M-1.0 x 10(-5) M under optimum conditions. The detection limit is 1.1 x 10(-8) M. The proposed method was successfully employed to determine 4-nitrophenol in lake water samples, and the recoveries of the spiked 4-nitrophenol were excellent (92-106%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)3(2+)) cathodic electrochemiluminescence (ECL) was generated at -0.78V at the Pt electrode in acetonitrile (ACN), which suggested that the cathodic ECL differed from conventional cathodic ECL It was found that tripropylamine (TPrA) could enhance this cathodic ECL and the linear range (log-log plot) was 0.2 mu M-0.2 mM. In addition, hydrogen peroxide (H2O2) could inhibit the cathodic ECL and was indirectly detected with the linear range of 27-540 mu M. The RSD (n = 12) of the ECL intensity in the presence of 135 mu M H2O2 was 0.87%. This method was also demonstrated for the fast determination of H2O2 in disinfectant sample and satisfactory results were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structural evolution of a single-layer latex film during annealing was studied via grazing incidence ultrasmall-angle X-ray scattering (GIUSAXS) and atomic force microscopy (AFM). The latex particles were composed of a low-T-g (-54 degrees C) core (n-butylacrylate, 30 wt %) and a high-T-g (41 degrees C) shell (t-butylacrylate, 70 wt %) and had an overall diameter of about 500 nm. GIUSAXS data indicate that the q(y) scan at q(z) = 0.27 nm(-1) (out-of-plane scan) contains information about both the structure factor and the form factor. The GIUSAXS data on latex films annealed at various temperatures ranging from room temperature to 140 degrees C indicate that the structure of the latex thin film beneath the surface changed significantly. The evolution of the out-of-plane scan plot reveals the surface reconstruction of the film. Furthermore, we also followed the time-dependent behavior of structural evolution when the latex film was annealed at a relatively low temperature (60 degrees C) where restructuring within the film can be followed that cannot be detected by AFM, which detects only surface morphology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Layer-by-layer assembly technique was used to construct ultrathin film of cowpea mosaic virus (CPMV) by electrostatic interactions, and the film was employed as a precursor on which an OF8T2 film was deposited by spin coating. Amplified spontaneous emission (ASE) was observed and improved for the OF8T2 film. Compared with OF8T2 film on quartz, the introduction of CPMV nanoparticles reduced the threshold and loss, and remarkably increased the net gain. The threshold, loss, and gain reached 0.05 mJ/ pulse, 6.9 cm(-1), and 82 cm(-1), respectively. CPMV nanoparticles may enormously scatter light, resulting in a positive feedback, thus the ASE is easily obtained and improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poly( ethylene oxide)-b-poly(N, N-dimethylacrylamide) (PEO-b-PDMA) was synthesized by successive atom transfer radical polymerization (ATRP) of N, N-dimethylacrylamide (DMA) monomer using PEO-Br macro initiators as initiator, CuBr and 5,5,7,12,12,14-hexamethyl-1,4,8,11-tetraazamacrocyclotetra decane (Me-6[14] aneN(4)) as catalyst and ligand. PEO-Br macroinitiator was synthesized by esterification of PEO with 2-bromoisobutyryl bromide. GPC and H-1 NMR studies show that the plot of ln([DMA](0)/[ DMA]) against the reaction time is linear, and the molecular weight of the resulting PDMA increased linearly with the conversion. Within 3 h, the polymerization can reach almost 60% of conversion. PEO-b-PDMA copolymer with low polydispersity index (M-w/M-n approximate to 1.1) is obtained. Self-assembly of PEO-b-PDMA in selective solvents is also studied. It could self-assemble into micelles in methanol/acetone (1/10, v/v) solution. TEM analyses of the PEO-b-PDMA micelles with narrow size distribution revealed that their size and shape depend much on the copolymer composition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extraction and stripping kinetics of yttrium(III) with bis(2,4,4-trimethylpentyl) phosphinic acid (Cyanex 272, HA) dissolved in heptane as an acid extractant have been investigated by constant interfacial cell with laminar flow. The experimental hydrodynamic conditions have been chosen so that the contribution of diffusion to the measured rate of reaction is minimized. The plot of interfacial area on the rate has shown a linear relationship, which makes the interface the most probable local for the chemical reactions. At the same time, the extraction thermodynamic and kinetic methods are compared to determine the equilibrium extraction constant. A rate equation and the rate-determining step of the extraction and stripping of yttrium(III) have also been obtained, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive electrochemiluminescent detection scheme by solid-phase extraction at Ru(bpy)(3)(2+)-modified ceramic carbon electrodes (CCEs) was developed. The as-prepared Ru(bpy)(3)(2+)-modified CCEs show much better long-term stability than other Nafion-based Ru(bpy)(3)(2+)-modified electrodes and enjoy the inherent advantages of CCEs. The log-log calibration plot for dioxopromethazine is linear from 1.0 x 10(-9) to 1.0 x 10(-4) mol L-1 using the new detection scheme. The detection limit is 6.6 x 10(-10) mol L-1 at a signal-to-noise ratio of 3. The new scheme improves the sensitivity by similar to 3 orders of magnitude, which is the most sensitive Ru(bpy)(3)(2+) ECL method. The scheme allows the detection of dioxopromethazine in a urine sample within 3 min. Since Ru(bpy)(3)(2+) ECL is a powerful technique for determination of numerous amine-containing substances, the new detection scheme holds great promise in measurement of free concentrations, investigation of protein-drug interactions and DNA-drug interactions, pharmaceutical analysis, and so on.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We described here a new method for the determination of total calcium in plasma. The method is based on the precipitation of calcium with excess oxalate and the measurement of residual oxalate by flow injection analysis with Ru(bpy)(3)(2+) electrochemiluminescent detection. It has the advantages of extremely stable reagent, user-friendly instrument, high selectivity, good analytical recovery, wide dynamic range, and nice correlation with atomic absorption spectroscopy. The calibration plot for calcium is linear over a concentration range from 0.5 mmol L-1 to 4.8 mmol L-1, which is wider than those obtained by most other methods. The analytical recoveries for plasma calcium are 98.4-101.2% with coefficients of variation (CVs) of 1.96-2.52%. The within-day CVs range from 0.76% to 0.95%, and between-day CVs were from 1.12% to 1.46%. The time for each injection is one minute. Because the proposed method can be readily carried out on increasingly popular instruments for Ru(bpy)(3)(2+) ECL immunoassays and DNA probe assays, Ru(bpy)32+ ECL method is suitable for routine clinical analysis of calcium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The yttrium(III) extraction kinetics and mechanism with bis-(2,4,4-trimethyl-pentyl) phosphinic acid (Cyanex 272, HA) dissolved in heptane have been investigated by constant interfacial cell with laminar flow. The data has been analyzed in terms of pseudo-first order constants. Studies on the effects of stirring rate, temperature, acidity in aqueous phase, and extractant concentration on the extraction rate show that the extraction regime is dependent on the extraction conditions. The plot of interfacial area on the rate has shown a linear relationship. This fact together with the strong surface activity of Cyanex 272 at heptane-water interfaces has made the interface the most probable location for the chemical reactions. The forward, reverse rate equations and extraction rate constant for the yttrium extraction with Cyanex 272 have been obtained under the experimental conditions. The rate-determining step has been also predicted from interfacial reaction models. The predictions have been found to be in good agreement with the rate equations obtained from experimental data, confirming the basic assumption that the chemical reaction is located at the liquid-liquid interface.