94 resultados para MM TUBE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this paper are to study the thermodynamic cycles in an inertance tube pulse tube refrigerator (ITPTR) by means of CFD method The simulation results show that gas parcels working in different parts of ITPTR undergo different thermodynamic cycles The net effects of those thermodynamic cycles are pumping heat from the low temperature part to the high temperature part of the system The simulation results also show that under different frequencies of piston movement the gas parcels working in the same part of the system will undergo the same type of thermodynamic cycles The simulated thermal cycles are compared with those thermodynamic analysis results from a reference Comparisons show that both CFD simulations and theoretical analysis predict the same type of thermal cycles at the same location However only CFD simulation can give the quantitative results while the thermodynamic analysis is still remaining in quality (C) 2010 Elsevier Ltd All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new methodology is proposed in this paper to predict the lowest power consumption for a double-tube-socket (DTS) pneumatic conveying system. This methodology is established on both experimental work and numerical simulation. After parametric studies by numerical simulation, the desired conveying cases which have the lowest power consumption were obtained. Finally those cases were carried out in our experimental system. The measured power consumption was close to that predicted. In this paper the experimental work is discussed and the numerical simulation introduced. (c) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The on-way peak overpressure and flame propagation speed of gas deflagration in the tube with obstacles are important data for process safety. Based on carbon monoxide deflagration experiments, the paper presents a multi-zone integration model for calculation of on-way peak overpressure, in which the tube with obstacles is considered as a series of venting explosion enclosures which link each others. The analysis of experimental data indicates that the on-way peak overpressure of gas deflagration can be correlated as an empirical formula with equivalence ratio of carbon monoxide oxidation, expansion ratio, flame path length, etc., and that the on-way peak overpressure exhibits a linear relationship with turbulence factor and flame propagation speed. An empirical formula of flame propagation speed is given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pipeline with a bypass is widely used for the pneumatic conveying of material. The double-tube-socket (DTS (R)) technology, which uses a special inner bypass, represents the current state of the art. Here, a new methodology is proposed based on the use of computational fluid dynamics (CFD) to predict the energy consumption of DTS conveying. The predicted results are in good agreement with those from pilot-scale experiments. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new methodology based on the use of CFD is proposed to estimate the energy consumptions in a DTS (DOUBLE-TUBE-SOCKET) pneumatic conveying. A simple computational program based on this methodology is developed. It can directly give the lowest energy consumption and the compatible gas consumption by only input the distance of conveying and the conveying tonnage. This computational program has been validated through our experimental work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A palladium membrane has been prepared by electroless plating on the surface of a porous stainless steel tube. Since the large surface pores of the tube are obstacle for preparation of a defect-free palladium film on the surface, zirconium oxide particles were deposited inside the pores. The mean thickness of the resulting Pd membrane on the modified tube was ca. 10 mum. It is suggested that the permeability of hydrogen is partly governed by gas diffusion in the pores. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed for the determination of micro mercury in the soil, plants and the traditional Chinese medicine using flow injection quartz tube-atomic absorption spectrometry. The effect of the factors such as acidity,. the carrier solution, the flow rate of reductive solution and argon gas, etc. on the determination was studied. When vanadic oxide, nitric acid and sulfuric acid were used to decompose the sample reliable result could be obtained. The characteristic mass of the method is 59 pg, the detection limit is 0.028 mug/L, RSD is < 3.9% and the recovery is in the range of 94% &SIM; 102%.