105 resultados para Line Integrals


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-hit 3-layer delay-line anode (Hexanode) has an increased ability to detect multi-hit events in a collision experiment. Coupled with a pair of micro-channel plates, it can provide position information of the particles even if the particles arrive at the same time or within small time dwell. But it suffers from some ambiguous outputs and signal losses due to timing order and triggering thresholds etc. We have developed a signal reconstruction program to correct those events. After the program correction, the dead time only exists when 2 paxticles arrive at the same time and the same position within a much smaller range. With the combination of Hexanode and the program, the experimental efficiencies will be greatly improved in near threshold double ionization on He collisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The history of experimental study on beta-delayed proton decays in the rare-earth region was simply reviewed. The physical results of the beta-delayed proton decays obtained at IMP, Lanzhou over the last 10 years were summarized, mainly including the first observation of 9 new beta-delayed proton precursors along the odd-Z proton drip line and the new data for 2 waiting-point nuclei in the rp-process. The results were compared and discussed with different nuclear model calculations. Finally, the perspective in near future was briefly introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new axial beam injection system is designed and being constructed at the HIRFL. It consists of 2 GLASSER lenses, 1 dipole, 5 quadrupoles and 3 solenoids. There are two beam line branches for 14.5GHz ECR ion source and 18.5GHz super conducting ECR ion source. Both transverse and longitudinal beam optics are improved in contrast with the old one. The layout, beam optics calculation results and further improved design are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

气体探测器有成本低廉、制备简单、性能可靠和方便使用等特点。研制了一种5层板结构的延迟线平行板雪崩电离室(PPAC),用于兰州放射性束流线(RIBLL)上开展的实验。在57.6MeV/u的6He束流条件下测试了这种探测器对高能轻粒子的适用性,得到了位置分辨为1.8mm(FWHM),时间分辨为2.6ns,以及可靠的探测效率。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

微束辐照装置是将辐照样品的束斑缩小到μm量级,能够对辐照粒子进行准确定位和精确计数的实验平台,是开展辐照材料学、辐照生物学、辐照生物医学和微加工的有力工具。μm量级的束流对设备的准直安装也提出了极高的要求,对于HIRFL系统微束线上的二极磁铁,由于其所在位置的空间相当狭小,使得设计就位时磁铁的位置及角度与地面做基准时的不同,这给安装准直工作带来了挑战。通过引入变化的基准坐标值的办法,有效解决了这一难题,使全部磁铁安装误差都控制在了要求的公差范围之内。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-spin states in Pd-101 have been investigated experimentally via the Ge-76(Si-28, 3n gamma)Pd-101 reaction. The previously known bands based on the d(5/2) and h(11/2) neutron orbitals have been extended to higher-spin states, and two new structures have been observed. Spin and parity were assigned to the levels on the basis of the experimental results of the angular distribution of gamma rays deexciting the oriented states. For the ground-state band, the E-GOS (E-Gamma Over Spin) curve strongly suggests a structure transition from vibration to rotation while increasing spin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The construction and evaluation of an on-column etched fused-silica porous junction for on-line coupling of capillary isoelectric focusing (CIEF) with capillary zone electrophoresis (CZE) are described. Where two separation columns were integrated on a single piece of fused-silica capillary through the etched similar to4 to 5-mm length porous junction along the capillary. The junction is easily prepared by etching a short section of the capillary wall with HF after removing the polyimide coating. The etched section becomes a porous glass membrane that allows only small ions related to the background electrolyte to pass through when high voltage is applied across the separation capillary. The primary advantages of this novel porous junction interface over previous designs (in which the interface is usually formed by fracturing the capillary followed by connecting the two capillaries with a section of microdialysis hollow fiber membrane) are no dead volume, simplicity, and ruggedness, which is particularly well suited for an on-line coupling capillary electrophoresis-based multiple dimensional separation system. The performance of the 2D CIEF-CZE system constructed by such an etched porous junction was evaluated by the analyses of protein mixtures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method involving self-concentration, on-column enrichment and field-amplified sample stacking for on-line concentration in capillary electrochromatography with a polymer monolithic column is presented. Since monolithic columns eliminate the frit fabrication and the problems associated with frits, the experimental conditions could be more flexibly adjusted to obtain higher concentration factor in comparison with conventional particulate packed columns. With self-concentration effect, the detection sensitivity of benzene and hexylbenzene is improved by a factor of 4 and 8, respectively. With on-column enrichment and ultralong injection, improvement as high as 22 000 times in detection sensitivity of benzoin is achieved. Furthermore, a combination of the three above-mentioned methods yields up to a 24000-fold improvement in detection sensitivity for caffeine, a charged compound. Parameters affecting the efficiency of on-line concentration are investigated systematically. In addition, equations describing on-line concentration process are deduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 muL and a washing solvent loop of 0.5 muL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An on-line two-dimensional (2D) capillary electrophoresis (CE) system consisting of capillary isoelectric focusing (CIEF) and capillary gel electrophoresis (CGE) was introduced. To validate this 2D system, a dialysis interface was developed by mounting a hollow fiber on a methacrylate resin plate to hyphenate the two CE modes. The two dimensions of capillary shared a cathode fixated into a reservoir in the methacrylate plate; thus, with three electrodes and only one high-voltage source, a 2D CE framework was successfully established. A practical 2D CIEF-CGE experiment was carried out to deal with a target protein, hemoglobin (Hb). After the Hb variants with different isoelectric points (pIs) were focused in various bands in the first-dimension capillary, they were chemically mobilized one after another and fed to the second-dimension capillary for further separation in polyacrylamide gel. During this procedure, a single CIEF band was separated into several peaks due to different molecular weights. The resulting electrophoregrarn is quite different from that of either CIEF or CGE; therefore, more information about the studied Hb sample can be obtained.