115 resultados para Invariant Line
Resumo:
We investigate the role of two-quasiparticle isomeric states along the proton drip line, using configuration-constrained potential-energy-surface calculations. In contrast to even-even nuclei, odd-odd nuclei can have coexisting low-lying two-quasiparticle states. The low excitation energy and high angular momentum can lead to long-lived isomers. Also, because of the hindrance by spin selection, the probabilities of beta and proton decays from high-spin isomers can be reduced significantly. The present calculations reproduce reasonably well the available data for observed isomers in such nuclei. Unobserved high-spin isomers are predicted, which could be useful for future experimental studies of exotic nuclei at and beyond the proton drip line.
Resumo:
We study the wave dislocations with an induced gauge potential. The topological current characterized the wave dislocations is constructed with the dual of Abelian gauge field. And the topological charges and locations of the wave dislocations are determined by the phi-mapping topological current theory. Furthermore, it is shown that the knotted wave dislocations can be described with a Hopf invariant in the wave field. At last we discussed the evolution of the knotted wave dislocations.
Resumo:
Multi-hit 3-layer delay-line anode (Hexanode) has an increased ability to detect multi-hit events in a collision experiment. Coupled with a pair of micro-channel plates, it can provide position information of the particles even if the particles arrive at the same time or within small time dwell. But it suffers from some ambiguous outputs and signal losses due to timing order and triggering thresholds etc. We have developed a signal reconstruction program to correct those events. After the program correction, the dead time only exists when 2 paxticles arrive at the same time and the same position within a much smaller range. With the combination of Hexanode and the program, the experimental efficiencies will be greatly improved in near threshold double ionization on He collisions.
Resumo:
The history of experimental study on beta-delayed proton decays in the rare-earth region was simply reviewed. The physical results of the beta-delayed proton decays obtained at IMP, Lanzhou over the last 10 years were summarized, mainly including the first observation of 9 new beta-delayed proton precursors along the odd-Z proton drip line and the new data for 2 waiting-point nuclei in the rp-process. The results were compared and discussed with different nuclear model calculations. Finally, the perspective in near future was briefly introduced.
Resumo:
We give a generalized Lagrangian density of 1 + 1 Dimensional O( 3) nonlinear sigma model with subsidiary constraints, different Lagrange multiplier fields and topological term, find a lost intrinsic constraint condition, convert the subsidiary constraints into inner constraints in the nonlinear sigma model, give the example of not introducing the lost constraint. N = 0, by comparing the example with the case of introducing the lost constraint, we obtain that when not introducing the lost constraint, one has to obtain a lot of various non-intrinsic constraints. We further deduce the gauge generator, give general BRST transformation of the model under the general conditions. It is discovered that there exists a gauge parameter beta originating from the freedom degree of BRST transformation in a general O( 3) nonlinear sigma model, and we gain the general commutation relations of ghost field.
Resumo:
A new axial beam injection system is designed and being constructed at the HIRFL. It consists of 2 GLASSER lenses, 1 dipole, 5 quadrupoles and 3 solenoids. There are two beam line branches for 14.5GHz ECR ion source and 18.5GHz super conducting ECR ion source. Both transverse and longitudinal beam optics are improved in contrast with the old one. The layout, beam optics calculation results and further improved design are given.
Resumo:
气体探测器有成本低廉、制备简单、性能可靠和方便使用等特点。研制了一种5层板结构的延迟线平行板雪崩电离室(PPAC),用于兰州放射性束流线(RIBLL)上开展的实验。在57.6MeV/u的6He束流条件下测试了这种探测器对高能轻粒子的适用性,得到了位置分辨为1.8mm(FWHM),时间分辨为2.6ns,以及可靠的探测效率。
Resumo:
微束辐照装置是将辐照样品的束斑缩小到μm量级,能够对辐照粒子进行准确定位和精确计数的实验平台,是开展辐照材料学、辐照生物学、辐照生物医学和微加工的有力工具。μm量级的束流对设备的准直安装也提出了极高的要求,对于HIRFL系统微束线上的二极磁铁,由于其所在位置的空间相当狭小,使得设计就位时磁铁的位置及角度与地面做基准时的不同,这给安装准直工作带来了挑战。通过引入变化的基准坐标值的办法,有效解决了这一难题,使全部磁铁安装误差都控制在了要求的公差范围之内。
Resumo:
High-spin states in Pd-101 have been investigated experimentally via the Ge-76(Si-28, 3n gamma)Pd-101 reaction. The previously known bands based on the d(5/2) and h(11/2) neutron orbitals have been extended to higher-spin states, and two new structures have been observed. Spin and parity were assigned to the levels on the basis of the experimental results of the angular distribution of gamma rays deexciting the oriented states. For the ground-state band, the E-GOS (E-Gamma Over Spin) curve strongly suggests a structure transition from vibration to rotation while increasing spin.
Resumo:
The construction and evaluation of an on-column etched fused-silica porous junction for on-line coupling of capillary isoelectric focusing (CIEF) with capillary zone electrophoresis (CZE) are described. Where two separation columns were integrated on a single piece of fused-silica capillary through the etched similar to4 to 5-mm length porous junction along the capillary. The junction is easily prepared by etching a short section of the capillary wall with HF after removing the polyimide coating. The etched section becomes a porous glass membrane that allows only small ions related to the background electrolyte to pass through when high voltage is applied across the separation capillary. The primary advantages of this novel porous junction interface over previous designs (in which the interface is usually formed by fracturing the capillary followed by connecting the two capillaries with a section of microdialysis hollow fiber membrane) are no dead volume, simplicity, and ruggedness, which is particularly well suited for an on-line coupling capillary electrophoresis-based multiple dimensional separation system. The performance of the 2D CIEF-CZE system constructed by such an etched porous junction was evaluated by the analyses of protein mixtures.