136 resultados para Calcium ion exchange capacity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Crude polysaccharide extracts were obtained from aqueous extracts of the microalgae Chlorella stigmatophora and Phaeodactylum tricornutum. The crude extracts were fractionated by ion-exchange chromatography on DEAE-cellulose columns. The molecular weights of the polysaccharides in each fraction were estimated by gel filtration on Sephacryl columns. The crude polysaccharide extracts of both microalgae showed anti-inflammatory activity in the carrageenan-induced paw edema test. In assays of effects on the delayed hyper-sensitivity response, and on phagocytic activity assayed in vivo and in vitro, the C. stigmatophora extract showed immunosuppressant effects, while the P. tricornutum extract showed immunostimulatory effects. Copyright © 2003 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review surveys the recent progress in the adsorbed stationary phases for capillary electrochromatography (CEC). Adsorption-based methods for preparation of stationary phase are novel approaches in CEC, which allow rapid and facile preparing stationary phases with desirable selectivity onto an open-tubular fused-silica capillary, a baresilica or ion-exchange packed column or a monolithic silica or polymer column. A variety of adsorbing agents have been developed as adsorbed stationary phases, including ionic long-chain surfactant, protein, peptide, amino acid, charged cyclodextrin (CD), basic compound, aliphatic ionene, and ion-exchange latex particle. The adsorbed stationary phases have been applied to separation of neutral, basic and acidic organic compounds, inorganic anions and enantiomers. They have also been applied to on-line sample concentration, fast separation and study of the competitive binding of enantiomers with protein.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

在试验过程中,通常采用一个土样进行连续试验来测定土壤的持水特征。此时,土样的有机质、黏粒矿物类型和阳离子交换量等性质基本保持不变,而土壤的容重在水力学和机械压力共同作用下会发生很大的变化。因此,我们认为实测的土壤持水特征不再是土壤吸力和含水量相对应的一条曲线,而是由土壤质量含水量、吸力和容重三变量共同确定的一个曲面。本文在Brooks-Corey土壤水分特征曲线模型的基础上,提出了两种描述土壤质量含水量、吸力和容重三变量关系的曲面模型,分析了模型的优缺点和适用条件,并采用离心机石蜡控容重法实测了四种质地填装土壤的三变量特征曲面。研究结果表明:土壤持水特征是由土壤质量含水量、吸力和容重三变量共同确定的一个曲面这一假设是合理的;类似于Brooks-Corey模型的两种幂函数经验曲面模型能够合理地描述填装土壤的实测数据,决定系数均大于0.94;模型Ⅰ的拟合效果略好于模型Ⅱ,但模型Ⅱ包含两个物理意义明确的参数,具有一定的优势。这一研究将为校正容重变化对土壤水力学参数的影响提供新的途径。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel periodic mesoporous organosilica (PMO) material was synthesized through one-step co-condensation of 1,2-bis(triethoxysilyl)ethane (BTESE) and benzoic acid-functionalized organosilane (BA-Si) using cetyltrimethylammonium bromide (CTAB) as a structure-directing agent under basic conditions. The materials were fully characterized by FTIR, XRD, N-2 adsorption-desorption isotherms and FESEM. FTIR spectra proved that BA-Si was successfully incorporated into the PMO materials (PMOs) via benzyl group as a linker. XRD and N-2 adsorption-desorption isotherms revealed the characteristic mesoporous structure with highly uniform pore size distributions. FESEM confirmed that the morphology of the PMOs was significantly dependent cri the molar ratio of two organosilica precursors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Composite membranes based on Sulfonated poly(ether ether ketone) (SPEEK) and sulfonated organically modified Si-SBA-15 (S-SBA-15) were investigated with the purpose of increasing the proton conductivity. The novelty of the composite membranes was attributed to two special structures and different ion exchange capacities (IEC) of S-SBA-15 fillers, which were embedded in membranes. The typical hexagonal channels array of S-SBA-15 was confirmed by XRD and TEM. The regular vermiculate and amorphous structures of the inorganic fillers were proved by SEM. Composite membranes were prepared through common solvent casting method. SEM images indicated that the inorganic filler with regular structure dispersed homogeneously in the composite membranes, but the amorphous filler caused an agglomeration phenomenon at the same loading content.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An effective electrochemiluminescence (ECL) sensor based on Nafion/poly(sodium 4-styrene sulfonate) (PSS) composite film-modified ITO electrode was developed. The Nafion/PSS/Ru composite film was characterized by atomic force microscopy, UV-vis absorbance spectroscopy and electrochemical experiments. The Nafion/PSS composite film could effectively immobilize tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) via ion-exchange and electrostatic interaction. The ECL behavior of Ru(bpy)(3)(2+) immobilized in Nafion/PSS composite film was investigated using tripropylamine (TPA) as an analyte. The detection limit (S/N = 3) for TPA at the Nafion/PSS/Ru composite-modified electrode was estimated to be 3.0 nM, which is 3 orders of magnitude lower than that obtained at the Nafion/Ru modified electrode. The Nafion/PSS/Ru composite film-modified indium tin oxide (ITO) electrode also exhibited good ECL stability. In addition, this kind of immobilization approach was simple, effective, and timesaving.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Counterions present at the surface of polyelectrolyte multilayers were utilized for the introduction of charged species into the multilayer via ion exchange. A typical polyelectrolyte multilayer film with Na+ counterions in the outermost layer was immersed in an AgNO3 aqueous solution and the rapid ion-exchange process was complete within 1 min. The silver ions thus introduced were then reduced in situ and silver nanoparticles were produced at the surface of the multilayer assembly. This example demonstrates that the counterions naturally occurring in every polyelectrolyte multilayer film can be a convenient vehicle for the introduction of various functionalities to the film.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The velvet antler polypeptide CNT14 was extracted and purified by gel filtration, ion exchange chromatography and RP C, which showed a single peak in HPLC chromatography and a single band in SDS-PAGE. The molecular weight measured by MALDI/TOF/MS spectrum was 1479. 9028. The polypeptide consisted mostly of Glu, Leu, Val, Pro. The amino acid sequence of the polypeptide was detected with ESI-MS/ MS, and the sequence was E-P-T-V-L-D-E-V-C-L-A-H-G-P. The experiments of biological activity of polypeptide CNT14 in vivo were carried out, and the results show that CNT14 has stimulant effects on the growth of rat HT22 cells. Then we produced the polypeptide CNT14 according the amino acid sequence by solid phase synthesis, confirmed the sequence of the polypeptide to be consistent with the amino acid sequence of polypeptide CNT14 which was separated from the velvet antler.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through a new and simple ion-exchange route, two-electron redox mediator thionine has been deliberately incorporated into the carbon nanotubes (CNTs)/Nafion composite film due to the fact that there is strong interaction between any of two among the three materials (ion-exchange process between thionine and Nafion, strong adsorption of thionine by CNTs, and wrapping and solubilizing of CNTs with Nation). The good homogenization of electron conductor CNTs in the integrated films provides the possibility of three-dimensional electron conductive network. The resulting integrated films exhibited high and stable electrocatalytic activity toward NADH oxidation with the significant decrease of high overpotential, which responds more sensitively more than those modified by thioine or CNTs alone. Such high electrocatalytic activity facilitated the low potential determination of NADH (as low as -0.1 V), which eliminated the interferences from other easily oxidizable species. In a word, the immobilization approach is very simple, timesaving and effective, which could be extended to the immobilization of other cationic redox mediators into the CNTs/Nafion composite film. And these features may offer potential promise for the design of amperometric biosensors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To improve the reproducibility, stability, and sensitivity of bismuth film electrode (BiFE), we studied the performances of a mixed coating of two cation-exchange polymers, Nafion (NA) and poly(sodium 4-styrenesulfonate) (PSS), modified glassy carbon BiFE (GC/NA-PSS/BiFE). The characteristics of GC/NA-PSS/BiFE were investigated by scanning electron microscopy and cyclic voltammetry. Various parameters were studied in terms of their effect on the anodic stripping voltarnmetry (ASV) signals. Under optimized conditions, the limits of detection were 71 ng L-1 for Cd(II) and 93 ng L-1 for Pb(II) with a 10 min preconcentration. The results exhibited that GC/NA-PSS/BiFE can be a reproducible and robust toot for monitor of trace metals by ASV rapidly and environmentally friendly, even in the presence of surface-active compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mass transfer behaviors of Cd(II), Fe(III), Zn(II), and Eu(III) in sulfuric acid solution using microporous hollow fiber membrane (HFM) containing bis(2,4,4-trimethylpentyl)monothiophosphinic acid (commercial name Cyanex302) were investigated in this paper. The experimental results showed that the values of the mass transfer coefficients (K-w) decreased with an increase of H+ concentration and increased with an increase of extractant Cyanex302 concentration. The mass transfer resistance of Eu3+ was the largest because K-w value of Eu3+ was the smallest. The order of mass transfer rate of metal ions at low pH was Cd > Zn > Fe > Eu. Mixtures of Zn2+ and Eu3+ or of Zn2+ and Cd2+ were well separated in a counter-current circulation experiment using two modules connected in series at different initial acidity and concentration ratio. These results indicate that a hollow fiber membrane extractor is capable of separating the mixture compounds by controlling the acidity of the aqueous solution and by exploiting different mass transfer kinetics. The interfacial activity of Cyanex302 in sulfuric acid solution was measured and interfacial parameters were obtained according to Gibbs adsorption equation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The extraction and stripping kinetics of yttrium(III) with bis(2,4,4-trimethylpentyl) phosphinic acid (Cyanex 272, HA) dissolved in heptane as an acid extractant have been investigated by constant interfacial cell with laminar flow. The experimental hydrodynamic conditions have been chosen so that the contribution of diffusion to the measured rate of reaction is minimized. The plot of interfacial area on the rate has shown a linear relationship, which makes the interface the most probable local for the chemical reactions. At the same time, the extraction thermodynamic and kinetic methods are compared to determine the equilibrium extraction constant. A rate equation and the rate-determining step of the extraction and stripping of yttrium(III) have also been obtained, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the extraction of Ce(IV) from nitric acid solutions is investigated using di-(2-ethylhexyl) 2-ethylhexyl phosphonate (DEHEHP, B) in heptane as extractant. Ce(IV) can be extracted effectively from nitric acid solution, whereas it is poorly extracted from sulfuric acid solution. Compared with some other organophosphorus esters, DEHEHP has moderate extractablity for Ce(IV). The extraction efficiency varies with diluent in the order: aliphatic hydrocarbons > nitrobenzene > aromatic hydrocarbons > carbon tetrachloride > chloroform. Regeneration and loading capacities of DEHEHP have also been examined. Ce(IV) extraction in HNO3 solutions as well as extraction of HNO3 and H2O have been systematically studied. The Ce(IV) extraction increases with an increasing of HNO3 concentration and exhibits the maximum distribution ratio at 1-1.5 mol/L HNO3. Nitric acid, as a source of nitrate ion, enhances the extraction of metal ion. But it also competes with metal ions for extractant molecules by its own extraction under high acidities. The proposed extraction process is described by the following equilibrium equations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The coordination reactions during the solvent extraction of cerium(IV) and fluorine(l) from mixed nitric acid and hydrofluoric acid solutions by di-(2-ethylhexyl)-2-ethylhexylphosphonate, L (DEHEHP) in heptane have been investigated. The extraction data have been analyzed by graphical methods taking into account all plausible species extracted into the organic phase. Different variables influencing the extraction of Ce(IV), such as the concentrations of nitrate ions, hydrofluroric acid, nitric acid, and extractant have been studied. The results demonstrate that DEHEHP can extract not only Ce(NO3)(4) as Ce(NO3)4.2L and HF as HF (.) H2O (.) L, but both together as Ce(HF)(NO3)(4) (.) L. The extraction equilibrium equations are determined according to slope analysis and IR spectra. The equilibrium constants of the extracted complexes have been calculated, taking into account complexation between the metal ion and inorganic ligands in the aqueous phase and all plausible complexes extracted into the organic phase. It is also shown that boric acid, which was added into the mixed solutions to complex with F(I) is not extracted by DEHEHP, and neither does it affect the extraction of cerium(IV) and HF, nor change the extraction mechanism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new electrogenerated chemiluminescence biosensor was fabricated by immobilizing ECL reagent Ru(bPY)(3)(2+) and alcohol dehydrogenase in sol-gel/chitosan/poly(sodium 4-styrene sulfonate) (PSS) organically modified composite material. The component PSS was used to immobilize ECL reagent Ru(bpy)(3)(2+) by ion-exchange, while the addition of chitosan was to prevent the cracking of conventional sol-gel-derived glasses and provide biocompatible microenvironment for alcohol dehydrogenase. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate and it was much simpler than previous double-layer design. The detection limit was 9.3 x 10(-6) M for alcohol (S/N = 3) with a linear range from 2.79 x 10(-5) to 5.78 x 10(-2) M. With ECL detection, the biosensor exhibited wide linear range, high sensitivity and good stability.