72 resultados para SERUM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary zone electrophoresis was used to monitor the interaction between bilirubin and human serum albumin. Cord blood serum samples were injected directly into an uncoated fused-silica capillary (30 cm x 50 mu m i.d.) and separation was accomplished within 4 min without extensive sample pretreatment. The most suitable running buffer to separate free bilirubin from albumin bound bilirubin was found to contain 1.0 mmol/L EDTA, 5% acetonitrile and 15 mmol/L phosphate with pH adjusted to 8.4. Approximately two bilirubin dianions could be bound per human serum albumin molecule in the cord blood serum. The binding constant was estimated to be 1.1 x 10(5) (L/mol) at 25 degrees C and pH 8.4. The peak area ratio of free bilirubin to total bilirubin can be used to determine the bilirubin binding capacity of cord blood serum for the concentration range of total bilirubin from 204 to 340 mu mol/L using 1:5 diluted cord blood seras. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the chiral separation of several basic drugs, dimetindene, tetryzoline, theodrenaline and verapamil, the liquid pre-column capillary electrophoresis (LPC-CE) technique was established. It was used to determine free concentrations of drug enantiomers in mixed solutions with human serum albumin (HSA). To prevent HSA entering the CE chiral separation zone, the mobility differences between HSA and drugs under a specific pH condition were employed in the LPC. Thus, the detection confusion caused by protein was totally avoided. Further study of binding constants determination and protein binding competitions was carried out. The study proves that the LPC technique could be used for complex media, particularly the matrix of protein coexisting with a variety of drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The protein binding constant, binding sites of the Strychnos alkaloid-strychnine and bovine serum albumin (BSA) was determined by capillary electrophoretic frontal analysis (CE-FA) for the first time. The experiment was carried out in a polyacrylamide-coated fused silica capillary (48.4 cmx50 mu m i.d., 38.1 cm effective length) with 20 mmol/L citrate/MES buffer (pH 6.0, ionic strength 0.17). The applied voltage was 12 kV and detection wavelength was set at 257 nm. The plateau height of the peak was employed to determine the unbound concentration of drug in BSA equilibrated sample solution based on the external drug standard in the absence of protein. The present method provides a convenient, accurate technique for the early stage of drug screening.