85 resultados para Lithospheric plates
Resumo:
根据石英晶体双折射率的色散特性,对石英波片的偏光干涉谱进行了理论分析和数值模拟,提出了一种石英波片延迟量和厚度的偏光干涉标定法。即由偏光干涉谱,可以得出石英波片在200~2000 nm宽光谱范围内的延迟量;通过对长波段的偏光干涉谱极值波长的精确判断,可以准确地计算出该石英波片的厚度。利用Lambda 900 紫外可见近红外分光光度计对一片石英波片的偏光干涉谱进行了测量。在波长精度为0.1 nm的情况下,测量的厚度精度为0.1 μm。误差分析结果表明,通过提高光谱的最小分辨力及选择较长的光谱波段进行测量计算
Resumo:
It is the first time in China that the phase variations and phase shift of microwave cavity in a miniature Rb fountain frequency standard are studied, considering the effect of imperfect metallic walls. Wall losses in the microwave cavity lead to small traveling wave components that deliver power from the cavity feed to the walls of cavity. The small traveling wave components produce a microradian distribution of phase throughout the cavity ity, and therefore distributed cavity phase shifts need to be considered. The microwave cavity is a TE011 circular cylinder copper cavity, with round cut-hole of end plates (14mm in diameter) for access for the atomic flux and two small apertures in the center of the side wall for coupling in microwave power. After attenuation alpha is calculated, field variations in cavity are solved. The field variations of the cavity are given. At the same time, the influences of loaded quality factor QL and diameter/height (2a/d) of the microwave cavity on the phase variations and phase shift are considered. According to the phase variation and phase shift of microwave cavity we select the parameters of cavity, diameter 2a = 69.2mm, height d = 34.6mm, QL = 5000, which will result in an uncertainty delta(Delta f / f0 ) < 4.7 x 10(-17) and meets the requirement for the miniature Rb fountain frequency standard with accuracy 10(-15).
Resumo:
The routing scheme and some permutation properties of a four-shuffle-exchange-based Omega network are discussed. The corresponding optical setup, which is composed of 2-D phase spatial light modulators and calcite plates, is proposed and demonstrated through mapping the inputs to a 2-D array. Instead of one shuffle-exchange followed by one switching operation as in ordinary Omega networks, in our presented system, the shuffle interconnection embraced in the switches is accomplished simply by varying the switching structure of each stage. For the proposed polarization-optical modules, the system is compact in structure, efficient in performance, and insensitive to the environment. (C) 1997 Society of Photo-Optical Instrumentation Engineers.
Resumo:
提出了一种将光弹调制器应用于偏振方向调制的方法.介绍了它的两种基本使用模式,利用琼斯矩阵对其偏振方向调制原理及其两种基本使用模式进行了分析。光弹调制器和1/4波片形成偏振方向调制器件时,光弹调制器处于两块透光轴相互垂直的1/4波片之间.且光弹调制器的振动轴分别和两块1/4波片的透光轴成±45°角,线偏振光通过此器件其偏振方向被调制。实验验证了光弹调制器组合1/4波片调制偏振方向的原理。将光弹调制器应用在偏振方向的调制中.使现有偏振方向调制技术的光谱范围扩展到了紫外波段。
Resumo:
We present a novel phase-shifting vectorial-shearing interferometer with a wedge plate phase-shifter. The interferometer is based on a modified Mach-Zehnder configuration; the common-path nature makes it capable of testing the wavefront of a short coherence-length light source, such as a laser diode. Vectorial shear (shearing in the x and y directions simultaneously) in an arbitrary direction is introduced by inserting two wedge plates orthogonally in two arms, respectively. One of the wedge plates is split into two parts (parallel part and wedge part); phase shift is produced by moving the wedge part in contact along the parallel part. The moving distance for a 2 pi phase shift is a few millimetres in specific conditions. The wedge plate phase-shifter increases the moving distance for phase shift and makes the control of phase shift relatively easy. We also discuss the lateral shear error and phase shift errors induced by wedge plates. The lateral shear error is small enough to be ignored; the phase shift error is determined mainly by the wedge angle error. Lastly, we give the experimental results of phase-shifting interference fringes in vectorial shear mode.
Resumo:
In order to measure the diffraction-limit wavefront, we present three types of common-path double-shearing interferometers based on the theory of double shearing. Two pairs of half-aperture or whole-aperture wedge plates are used to introduce opposite tilt to realize the double-shearing function. By comparing the fringe widths in two fields, the marginal wavefront aberration can be obtained. In the paper, we give three different configurations: half-aperture configuration, whole-field configuration and double-interferometer configuration. The half-aperture configuration has the features of high sensitivity, stabilization and easy alignment. For the whole-field configuration, the interference fringes are displayed in two whole fields. Consequently, the divergent or convergent characteristic and aberration types of a wavefront can be identified visually. The whole-field configuration can be changed to the double-interferometer configuration for continuous test. Both small and large wavefront aberrations can be measured by the double-interferometer configuration. The minimum detectable wavefront aberration (W-0)(min) comes to 0.03 lambda. Lastly, we present the experimental results for the three types of double-shearing interferometers.
Resumo:
A new set of pure phase filters for realizing transverse superresolution is presented in this paper. The filters, whose significant features are their ability to tune and their simplicity, consist of one half-wave plate between two quarter-wave plates; the half-wave plate is made of two zones that can rotate with respect to each other. By rotating any zone of the half-wave plate, the central lobe width of the irradiance point spread function (PSF) in the transverse direction can be tunably reduced. At the same time, the axial intensity distribution is analysed in detail.
Resumo:
This paper summarized the recent research results of Changhe Zhou's group of Information Optics Lab in Shanghai Institute of Optics and Fine Mechanics (SIOM). The first is about the Talbot self-imaging research. We have found the symmetry rule, the regular-rearranged neighboring phase difference rule and the prime-number decamping rule, which is briefly summarized in a recent educational publication of Optics and Photonics News, pp.46-50, November 2004. The second is about four novel microoptical gratings designed and fabricated in SIOM. The third is about the design and fabrication of novel supperresolution phase plates for beam shaping and possible use in optical storage. The fourth is to develop novel femtosecond laser information processing techniques by incorporating microoptical elements, for example, use of a pair of reflective Dammann gratings for splitting the femtosecond laser pulses. The most attractive feature of this approach is that the conventional beam splitter is avoided. The conventional beam splitter would introduce the unequal dispersion due to the broadband spectrum of ultrashort laser pulses, which will affect the splitting result. We implemented the Dammann splitting apparatus by using two-layered reflective Dammann gratings, which generates the almost same array without angular dispersion. We believe that our device is highly interesting for splitting femtosecond laser pulses.
Resumo:
提出一种精确测量波片相位延迟的方法。将待测波片置于起偏器和检偏器之间,转动待测波片和检偏器至不同的位置并探测输出的光强,得到波片的相位延迟。采用光源调制技术和解调技术,抑制了连续光所无法克服的背景光干扰和电子噪声的干扰;将光路分为测量光路和参考光路,采用软件除法技术,消除了光源波动的影响,从而实现波片相位延迟的精确测量。详细分析了影响测量精度的误差因素,主要有光源波长变化、温度变化、入射角倾斜、转台转角误差和光源波动,计算了1064 nm波长时厚度为0.52 mm的λ/4多级结晶石英波片产生的相位延迟误差
Resumo:
在起偏器待测波片检偏器系统基础上提出一种四区域测量波片相位延迟量的方法。调整待测波片和检偏器的方位角,获得相应的四组光强值,通过线性运算得到待测波片的相位延迟量,完全消除了起偏器和检偏器不完全消光带来的误差。由于测量系统中不存在标准波片或其他相位调制元件,允许测量波长仅受偏振棱镜和探测器的限制,因此四区域法可适用于很大波长范围内的波片测量。以λ/4波片为例,理论分析了测量系统利用四区域测量法后的仪器误差为σ≤±3.49065×10-3rad(约0.2°),精度比原算法提高约1个数量级。实验验证了四区域法能有效提高系统精度。
Resumo:
Properties of N31 phosphate laser glass by continuous melting were studied, and key technologies were explored during continuous-melting phosphate laser glass. Crux of the matter such as dehydroxylating, Pt-inclusions and so on were solved through continuous-melting experiments. 80×50×5 cm3 big plates were made and the glass properties were measured. Compared with pot melting, the glass by continuous-melting in full compliance with the spectrum and laser requirements, furthermore continuous-melting has more advantages.
Resumo:
The theory of optical subdivision techniques of dual-frequency laser interferometers is stated. And a novel optical subdivision technique is proposed originally to enhance resolution of a commercial interferometer by adding some corner-cubes. Then the performance of the interferometer is tested. The interferometer resolution of 1.24 nm and the average error of below 2 nm are achieved by using the technique. The most novel of the optical subdivision technique is without lambda/4 plates. It is less sensitive to environmental changes, it has prodigious potential to improve resolution farther and it can reduce polarization mixing error. (C) 2007 Elsevier GmbH. All rights reserved.
Resumo:
研究了温度梯度法生长的γ-LiAlO2晶体在1100℃下富Li气氛和空气中退火处理后的表面形貌、表面结构以及吸收光谱。发现γ-LiAlO2晶体的抛光面在1100℃空气中退火后变为粗糙面,X射线衍射(XRD)分析表明此粗糙面为单相的LiAl5O8。而γ-LiAlO2晶体的抛光面在1100℃富Li气氛中处理后几乎没有变化。同时对不同气氛下热处理的γ-LiAlO2晶体进行了光谱分析,确认了晶片中196nm的吸收峰是由Li空位引起的。
Resumo:
Thermal stress-induced birefringence in borate glass which has been irradiated by 800-nm femtosecond laser pulses is observed under cross-polarized light. Due to the high temperature and pressure formed in the focal volume, the material at the edge of the micro-modified region is compressed between the expanding region and the unheated one, then stress emerges. Raman spectroscopy is used to investigate the stress distribution in the micro-modified region and indicates the redistributions of density and refractive index by Raman peak shift. We suggest that this technique can develop waveguide polarizers and Fresnel zone plates in integrated optics.
Resumo:
Amphioxus is a crucial organism for the study of vertebrate evolution. Although a genomic BAC library of Branchiostoma floridae has been constructed, we report here another BAC library construction of its distant relative species Branchiostoma belcheri. The amphioxus BAC library established in present study consists of 45,312 clones arrayed in one hundred and eighteen 384-well plates. The average insert fragment size was 120 kb estimated by Pulsed Field Gel Electrophoresis (PFGE) analysis of 318 randomly selected clones. The representation of the library is about 12 equivalent to the genome, allowing a 99.9995% probability of recovering any specific sequence of interest. We further screened the library with 4 single copied Amphi-Pax genes and identified total of 26 positive clones with average of 6.5 clones for each gene. The result indicates this library is well suited for many applications and should also serve as a useful complemental resource for the scientific community.