96 resultados para Label fusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chinese Academy of Sciences ; National Science Foundation of China [41071059]; National Key Technology R&D Program of China [2008BAK50B06-02]; National Basic Research Program of China [2010CB950900, 2010CB950704]; Natural Sciences and Engineering Research Council of Canada

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semisupervised dimensionality reduction has been attracting much attention as it not only utilizes both labeled and unlabeled data simultaneously, but also works well in the situation of out-of-sample. This paper proposes an effective approach of semisupervised dimensionality reduction through label propagation and label regression. Different from previous efforts, the new approach propagates the label information from labeled to unlabeled data with a well-designed mechanism of random walks, in which outliers are effectively detected and the obtained virtual labels of unlabeled data can be well encoded in a weighted regression model. These virtual labels are thereafter regressed with a linear model to calculate the projection matrix for dimensionality reduction. By this means, when the manifold or the clustering assumption of data is satisfied, the labels of labeled data can be correctly propagated to the unlabeled data; and thus, the proposed approach utilizes the labeled and the unlabeled data more effectively than previous work. Experimental results are carried out upon several databases, and the advantage of the new approach is well demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aptamers, which are in vitro selected functional oligonucleotides, have been employed to design novel biosensors (i.e., aptasensors) due to their inherent selectivity, affinity, and their multifarious advantages over traditional recognition elements. In this work, we reported a multifunctional reusable label-free electrochemical biosensor based on an integrated aptamer for parallel detection of adenosine triphosphate (ATP) and alpha-thrombin, by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). A An electrode as the sensing surface was modified with a part DNA duplex which contained a 5'-thiolated partly complementary strand (PCS) and a mixed aptamer (MBA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With a designed high-activity DNAzyme as the catalytic label, an ultrasensitive chemiluminescence thrombin aptasensor is developed, enabling a 10- to 100-fold improvement in the detection sensitivity as compared with previous counterparts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative electrochemilumineseence (ECL) detection of a model protein, bovine serum albumin (BSA) was achieved via biotin-avidin interaction using an avidin-based sensor and a well-developed ECL system of tris(2,2'-bipyridine) ruthenium(II) derivative as label and tri-n-propylamine (TPA) as coreactant. To detect the protein, avidin was linked to the glassy carbon electrode through passive adsorptions and covalent interaction with carboxylate-terminated carbon nanotubes that was used as binder to immobilize avidin onto the electrode. Then, biotinylated BSA tagged with tris(2,2'-bipyridine) ruthenium(II) label was attached to the prepared avidin surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the dimer-monomer equilibrium movement of the fluorescent dye Pyronin Y (PY), a rapid, simple, highly sensitive, label-free method for protein detection was developed by microchip electrophoresis with LIF detection. PY formed a nonfluorescent dimer induced by the premicellar aggregation of an anionic surfactant, SDS, however, the fluorescence intensity of the system increased dramatically when proteins such as BSA, bovine hemoglobin, cytochrome c, and trypsin were added to the solution due to the transition of dimer to fluorescent monomer. Furthermore, 1-ethyl-3-methylimidazolium tetrafluoroborate (EMImBF(4)) instead of PBS was applied as running buffers in microchip electrophoresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amyloid beta peptide plays a critical role in the pathogenesis of Alzheimer's disease (AD). Metal ions are highly enriched in cerebral amyloid deposits in AD and are proposed to be able to mediate A beta conformation. Therefore, a rapid, low-cost, and sensitive detection of metal-induced A beta aggregation and their relation to AD is clearly needed for the clinical diagnosis and treatment. In this report, we study metal-induced A beta aggregation by a rapid, label-free electrochemical method and monitor both the aggregation kinetics and the morphology in the absence or presence of Zn (II) and Cu (II).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Ru(bpy)2dppz]2+ electrochemiluminescence (ECL) was studied, and it was used to investigate DNA interaction and develop a label-free ATP aptasensor for the first time. ECL of [Ru(bpy)2dppz]2+ is negligible in aqueous solution, and increases approximately 1000 times when [Ru(bpy)2dppz]2+ intercalates into the nucleic acid structure. The ECL switch behavior of [Ru(bpy)2dppz]2+ is ascribed to the intercalation that shields the phenazine nitrogens from the solvent and results in a luminescent excited state. The ECL switch by DNA was applied to investigate the interaction of [Ru(bpy)2dppz]2+ with herring sperm DNA. The calculated equilibrium constant (K) is 1.35 x 10(6) M(-1), and the calculated binding-site size (s) is 0.88 base pair, which is consistent with the reported values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mercury ion (Hg2+) is able to specifically bind to the thymine-thymine (T-T) base pair in a DNA duplex, thus providing a rationale for DNA-based selective detection of Hg2+ with various means. In this work, we for the first time utilize the Hg2+-mediated T-T base pair to modulate the proper folding of G-quadruplex DNAs and inhibit the DNAzyme activity, thereby pioneering a facile approach to sense Hg2+ with colorimetry. Two bimolecular DNA G-quadruplexes containing many T residues are adopted here, which function well in low- and high-salt conditions, respectively. These G-quadruplex DNAs are able to bind hemin to form the peroxidase-like DNAzymes in the folded state. Upon addition of Hg2+, the proper folding of G-quadruplex DNAs is inhibited due to the formation of T-Hg2+-T complex. Ibis is reflected by the notable change of the Soret band of hemin when investigated by using UV-vis absorption spectroscopy. As a result of Hg2+ inhibition, a sharp decrease in the catalytic activity toward the H2O2-mediated oxidation of 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid)diammonium salt (ABTS) is observed, accompanied by a change in solution color. Through this approach, aqueous Hg2+ can be detected at 50 nM (10 ppb) with colorimetry in a facile way, with high selectivity against other metal ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have demonstrated a smart polymeric transducer and aptamer/intercalating dye system that allows the label-free detection of protein with high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A DNAzyme-based label-free method for the colorimetric detection of DNA is introduced, with a supramolecular hemin G-quartet complex as the sensing element and a 36-mer single-strand DNA as the analyte that is detected at 10 nM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Label free electrochemiluminescence (ECL) DNA detection based on catalytic guanine and adenine bases oxidation using tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] modified glassy carbon (GC) electrode was demonstrated in this work. The modified GC electrode was prepared by casting carbon nanotubes (CNT)/Nafion/Ru(bpy)(3)(2+) composite film on the electrode surface. ECL signals of doublestranded DNA and their thermally denatured counterparts can be distinctly discriminated using cyclic voltammetry (CV) with a low concentration (3.04 x 10(-8) mol/L for Salmon Testes-DNA). Most importantly, sensitive single-base mismatch detection of p53 gene sequence segment was realized with 3.93 x 10(-10) mol/L employing CV stimulation (ECL signal of C/A mismatched DNA oligonucleotides was 1.5-fold higher than that of fully base-paired DNA oligonucleotides). Label free, high sensitivity and simplicity for single-base mismatch discrimination were the main advantages of the present ECL technique for DNA detection over the traditional DNA sensors.