117 resultados para Fluorescence-based Imaging


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A time-resolved fluorescence immunoassay (TRFIA), based on anti-microcystin-LR (MCLR) monoclonal antibodies (MAbs) and europium-labeled antimouse IgG conjugate, was first developed for microcystin detection. Methods: Anti-MCLR MAbs were prepared by a standard method, and the attained MAbs showed a good cross reactivity with MCLR, MCRR and MCYR. The TRFIA was performed in an indirect competitive mode. The detection method of TRFIA was compared with indirect competitive enzyme-linked immunosorbent assay (ELISA) and high-performance liquid chromatography (HPLC). Results: The TRFIA exhibited a typical sigmoidal response for MCLR at concentrations of 0.005-50 ng/ml, with a wide quantitative range between 0.01 and 10 ng/ml, indicating the broadest detective range and the most sensitive of all the methods for microcystins (MCs) detection. Additionally, the TRFIA maintained good reliability through its quantitative range, as evidenced by low coefficients of variation (1.6-12.2%). The toxin data of algal samples assayed from TRFIA were in the same range as those with ELISA and HPLC, implying that the method was reliable and practical for the detection of MCs. Conclusions: The TRFIA may offer a valuable alternative or a substitute for conventional ELISA for microcystin detection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GaN films grown on sapphire substrate with an emphasis on epitaxial lateral overgrown (ELOG) layers with an array of rhombic shaped mask area as well as InGaN/GaN MQW laser diode layer structures were investigated by cathodoluminescence (CL) spectroscopy and CL imaging at room and low temperatures. The microscopic imaging with a high-spatial resolution clearly reveals the distribution of threading dislocations and point defects in ELOG GaN films. The secondary electron and CL data measured on cleaved faces of laser diodes are analyzed in consideration with luminescence mechanisms in semiconductor heterostructures and around the p - n junction, providing important information on the defects and carrier dynamics in laser diode devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CdS clusters are formed in the pores of a mesoporous zeolite in which the size of the clusters may be adjusted. The size of the clusters increases as the CdS loading is increased. X-ray diffraction investigation shows that the lattice constants of the clusters contract upon increasing size. This contraction is attributed to an increase of the static pressure exercised by the zeolite framework as the clusters grow bigger. Both the excitonic and trapped emission bands are detected and become more intensive upon decreasing size. Three absorption bands appear in the photoluminescence excitation (PLE) spectra and they shift to the blue as cluster size decreases. Based on the effective-mass approximation, the three bands are assigned to the 1S-1S, 1S-1P and 1S-1D transitions, respectively. The size-dependence of the PLE spectra can also be explained. (C) 1997 Elsevier Science Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pt/AlGaN/AlN/GaN Schottky diodes have been fabricated and characterized for H-2 sensing. Platinum (Pt) with a thickness of 20nm was evaporated on the sample to form the Schottky contact. The ohmic contact, formed by evaporated Ti/Al/Ni/Au metals, was subsequently annealed by a rapid thermal treatment at 860 degrees C for 30 s in N-2 ambience. Both the forward and reverse current of the device increased greatly when exposed to H-2 gas. The sensor's responses under different hydrogen concentrations from 500ppm to 10% H-2 in N-2 at 300K were investigated. A shift of 0.45V at 297K is obtained at a fixed forward current for switching from N-2 to 10% H-2 in N-2. Time response of the sensor at a fixed bias of 0.5 V was also measured. The turn-on response of the device was rapid, while the recovery of the sensor at N-2 atmosphere was rather slow. But it recovered quickly when the device was exposed to the air. The decrease in the barrier height of the diode was calculated to be about 160meV upon introduction of 10% H-2 into the ambient. The sensitivity of the sensor is also calculated. Some thermodynamics analyses have been done according to the Langmuir isotherm equation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a novel X-ray frame camera with variable exposure time that is based on double-gated micro-channel plates (MCP). Two MCPs are connected so that their channels form a Chevron-MCP structure, and four parallel micro-strip lines (MSLs) are deposited on each surface of the Chevron-MCP. The MSLs on opposing surfaces of the Chevron-MCP are oriented normal to each other and subjected to high voltage. The MSLs on the input and output surfaces are fed high voltage pulses to form a gating action. In forming two-dimensional images, modifying the width of the gating pulse serves to set exposure times (ranging from ps to ms) and modifying the delay between each gating pulse serves to set capture times. This prototype provides a new tool for high-speed X-ray imaging, and this paper presents both simulations and experimental results obtained with the camera.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mechanism of beam splitting and principle of wide-field-of-view compensation of modified Savart polariscope in the wide-field-of-view polarization interference imaging spectrometer (WPIIS) are analyzed and discussed. Formulas for the lateral displacement and optical path difference (OPD) produced by the modified Savart polariscope are derived by ray-tracing method. The theoretical and practical guidance is thereby provided for the study, design, modulation, experiment and engineering of the polarization interference imaging spectrometers and other birefringent Fourier-transform spectrometers based on Savart polariscopes. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many-beam dynamical simulations and observations have been made for large-angle convergent-beam electron diffraction (LACBED) imaging of crystal defects, such as stacking faults and dislocations. The simulations are based on a general matrix formulation of dynamical electron diffraction theory by Peng and Whelan, and the results are compared with experimental LACBED images of stacking faults and dislocations of Si angle crystals. Excellent agreement is achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wavefront coding is a powerful technique that can be used to extend the depth of field of an incoherent imaging system. By adding a suitable phase mask to the aperture plane, the optical transfer function of a conventional imaging system can be made defocus invariant. Since 1995, when a cubic phase mask was first suggested, many kinds of phase masks have been proposed to achieve the goal of depth extension. In this Letter, a phase mask based on sinusoidal function is designed to enrich the family of phase masks. Numerical evaluation demonstrates that the proposed mask is not only less sensitive to focus errors than cubic, exponential, and modified logarithmic masks are, but it also has a smaller point-spread-function shifting effect. (C) 2010 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A miniaturized fluorescence detector using a high-brightness light-emitting diode as an excitation source was constructed and evaluated. A windowless flow cell based on a commercial four-port cross fitting was designed to reduce the stray-light level and to eliminate the optical alignment. The observed detection limit for fluorescein was 26 nM in the continuous-flow mode. The error in the reproducibility of the responses was evaluated by the FIA method, and was found to be within 2% RSD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mutation of hMLH1 gene plays an important role in human tumorigenesis. A highly sensitive single-strand conformation polymorphism (SSCP) method for detection of the T1151A mutation in exon 12 of the hMLH1 gene was for the first time developed employing laser-induced fluorescence capillary electrophoresis (LIF-CE). Effects of the concentration of linear polyacrylamide solution, running temperature, running voltage and the addition of glycerol on SSCP analysis were investigated, and the optimum separation conditions were defined. Thirty colorectal cancer patients and eight lung cancer patients were screened and the T1151A mutation was found in four of them. Based on CE-sequencing the mutation was further confirmed. To our knowledge, this is for the first time that the T1151A mutation is found in lung cancer. Our method is simple, rapid, and highly sensitive and is well suited to the analysis of large numbers of clinical samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Characteristics of white organic light-emitting devices based on phosphor sensitized fluorescence are improved by using a multiple-emissive-layer structure, in which a phosphorescent blue emissive layer is sandwiched between red and green&yellow ones. In this device, bis[(4,6-difluorophenyl)-pyridinato-N,C-2] (picolinato), bis(2,4-diphenyl-quinoline) iridium (III) acetylanetonate, fac bis (2-phenylpyridine) iridium, and 5,6,11,12-tetraphenylnaphthacene are used as blue, red, green, and yellow emitters, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we report the first application of water-soluble fluorescent Ag nanoclusters in fluorescent sensors. The fluorescence of poly(methacrylic acid) (PMAA)-templated Ag nanoclusters was found to be quenched effectively by Cu2+, but not when other common metal ions were present. By virtue of the specific response toward the analyte, a new, simple, and sensitive fluorescent method for detecting Cu2+ has been developed based on Ag nanoclusters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple light scattering detection method for neurotransmitters has been developed, based on the growth of gold nanoparticles. Neurotransmitters (dopamine, L-dopa, noradrenaline and adrenaline) can effectively function as active reducing agents for generating gold nanoparticles, which result in enhanced light scattering signals. The strong light scattering of gold nanoparticles then allows the quantitative detection of the neurotransmitters simply by using a common spectrofluorometer.