205 resultados para EXTRACTION COLUMNS
Resumo:
A sol-gel coating method for the preparation of extractive phase on bars used in sorptive microextraction is described. The extraction phase of poly(dimethylsiloxane) is partially crosslinked with the sol-gel network, and the most part is physically incorporated in the network. Three aging steps at different temperatures are applied to complete the crosslinking process. Thirty-micrometer-thick coating layer is obtained by one coating process. The improved coating shows good thermal stability up to 300degreesC. Spiked aqueous samples containing n-alkanes, polycyclic aromatic hydrocarbons and organophosphorus pesticides were analyzed by using the sorptive bars and GC. The results demonstrate that it is suitable for both aploar and polar analytes. The detection limit for chrysene is 7.44 ng/L, 0.74 ng/L for C-19 and 0.9 ng/L for phorate. The extraction equilibration can be reached in less than 15 min by supersonic extraction with the bars of 30 mum coating layer. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The dynamic flow profiles and separation performances in conically shaped preparative liquid chromatographic columns (inlet i.d. larger than outlet i.d.) with three different angles (7, 10 and 15degrees) were studied and compared with cylindrical column of the same length and internal volume. The shapes of dynamic flow profiles were studied by on-column visualization method. The transparent chromatographic columns made of polymethyl methacrylate (PMMA), packed with C-18 bonded silica, were immerged into a cubic pool filled with glycerol to eliminate the cylindrical and conical lens effect. The flow profiles of colored iodine solution in the columns were observed clearly using cyclohexane as mobile phase since the refractive indices of C-18, column wall and the mobile phase are very close. In the conical column of 15degrees (20-7 mm i.d.) the mobile phase in the central region migrated slower than in wall region as it moved toward the column outlet, while in the conical column of 7degrees (17-11 mm i.d.) the mobile phase in the central region migrated faster than in wall region just like in cylindrical column. We found that a plug-like flow profile was generated in the conical column of 10degrees (18-9 mm i.d.) during the whole migration process. A carmine and brilliant blue mixture was used as a probe to test the separation ability of the columns. The resolutions of the two compounds on the conical column of 7, 10, 15degrees and on the cylindrical column were 0.6, 1.57, 1.29 and 0.8, respectively. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Three molecularly imprinted monolithic columns with different length but almost identical column volume had been prepared. It was observed that the separation factors of diastereomers and enantiomers were almost unaffected by column length. However, the short column with dimension of 38 mm x 8 mm W. showed much lower resistance to flow rate so that it could be operated at much higher flow rates. By combining stepwise gradient elution with elevated flow rate, the diastereomers of cinchonine and cinchonidine and the enantiomers of Cbz-DL-Trp and Fmoc-DL-Trp were successfully separated within 3 min on the short column with dimension of 38 mm. x 8 mm i.d.. Based on the above results, a cinchonine imprinted monolithic disk with dimension of 10 mm x 16 mm W. was further developed. The SEM image and the pore size distribution profile showed that large flow-through pores are present on the prepared monolith, which allowed mobile phase to flow through the disk with very low resistance. Chromatographic performances on the monolithic disk were almost unchanged compared with the long columns. A rapid separation of cinchonine and cinchonidine was achieved in 2.5 min at the flow rate of 9.0 ml/min. Furthermore, it was observed that there was almost no effect of the flow rate on the dynamic binding capacity at high flow rates. In addition, the effect of the loading concentration of analytes on the dynamic binding capacity, namely adsorption isotherm, was also investigated. A non-linear adsorption isotherm of cinchonine was observed on the molecularly imprinted monolith with cinchonine as template, which might be a main reason to result in the peak tailing of template molecule. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The dynamic flow profiles and column efficiencies in conically shaped semi-preparative liquid chromatographic columns (inlet ID larger than outlet ID) with two different conical angles (7degrees and 15degrees) were studied. The dynamic flow profiles were studied by an on-column visualization method. Conical columns were compared with cylindrical column of the same length and internal volume. The results showed that the flow profile of a sample band in the conical column of 7degrees (50 mm x 17 mm --> 11 mm ID) was parabolic in shape. The sample band migrated slower in the wall region than in the central region, as in the cylindrical column (50 mm x 14 mm ID). However, the sample band in the conical column of 15degrees (50 mm x 20 mm --> 7 mm ID) migrated slower in the central region than in the wall region, resulting in a reverse parabolic flow profile, in contrast to that in cylindrical column. This indicated that a flat flow profile might be realized in a conical column with a conical angle between 7degrees and 15degrees. The conical column of 15degrees had the highest column efficiency among the three columns under the same conditions. Compared with the cylindrical column packed with identical packing material, the conical column of 15degrees had 22%-45% higher column efficiency and 11%-27% higher peak height.
Resumo:
A sorbent showing specific affinity for nicotine was prepared by molecular imprinting technique, using nicotine as the template, methacrylic acid (MAA) as the functional monomer, ethyleneglycol dimethacrylate (EDMA) as the crosslinker and chloroform as the porogen. UV spectroscopic analysis in the molecular imprinting prepolymerization stage confirmed that nicotine could complex with the functional monomer by electrostatic interaction (ionic interaction and hydrogen bonding). The affinity and the binding properties of the imprinted polymer towards nicotine were investigated by equilibrium rebinding experiments. The results indicated the presence of nicotine-specific binding sites in the imprinted polymer, and that the imprinted polymer had a good capacity (90 mumol/g polymer) for nicotine. The elution conditions were optimized on the column packed with the imprinted polymer to elute nicotine quantitatively. The imprinted polymer was used as a solid-phase extraction (SPE) material for the removal of nicotine from tobacco smoke. The results obtained showed that the imprinted polymer was superior in terms of removing nicotine in tobacco smoke, compared with the commercial filter tip.
Resumo:
Monolithic columns of capillary electrochromatography (CEC) with weak electroosmotic flow (EOF) have been prepared by in situ polymerization of butyl methacrylate and ethylene dimethacrylate, without any charged groups in the reaction mixture. The reproducibility of such columns has been proved good no matter whether they are prepared in the same batch or in different batches. In the case of BMA-EDMA monoliths, besides the traditional ternary mixture - 1-propanol, 1,4-butanediol, and water, binary porogenic solvents with only alcohols have also been adopted. Compared with ternary porogenic solvents, the design with binary ones allows for fine control of the pore diameter and the formation of the specific surface of the monolithic polymers. The composition of porogenic reagents has also been shown to have an effect on EOF in the column systems. In addition, the Joule heat effect in such columns has been studied by varying the inner diameter of columns. Through the separation of acidic compounds, monolithic columns with low EOF have shown potential in the analysis of charged samples.
Resumo:
Selective extraction of Mercury(II) using 1-naphthylthiourea-methyl isobutyl ketone (ANTU-MIBK) system from hydrochloric acid solutions (0.1-10 M) has been studied. Influence of foreign ions, acid and ligand concentrations has been investigated. Addition of ANTU in MIBK enhanced, extraction capacity of MIBK to several times. Low effect of foreign ions and high separation factors for a number of metal ions determined at 0.5 M hydrochloric acid concentration evaluated the proposed method efficient and selective. The experimental data obtained from application of the method for extraction of mercury from a synthetic aqueous solution reveal that more than 99% mercury can be separated from cadmium, zinc and selenium in a single step with five minutes equilibration
Resumo:
We have found that a commonly used complexation and solvent extraction technique (using mixed dithiocarbamates/Freon/HNO3) does not always extract Cd, Co, Cu and Ni from estuarine samples with the same efficiency as from Milli-Q water. For samples collected from the Derwent Estuary (Australia), the reduced extraction efficiency only occurred for unfiltered samples, but low extraction efficiencies were also observed for a (filtered) riverine certified reference material (SLRS-3) suggesting that the effect may be widespread. We have not been able to identify the reason for the low extraction efficiency and, although it is strongly correlated with the presence of high concentrations of suspended solids, dissolved organic matter and particulate iron, we have no experimental evidence to directly link any of these parameters to the effect. It is possible that similar effects may occur in other techniques which rely on a preconcentration step prior to analysis and that some literature values of heavy metals in estuarine waters may be low. We propose a modification of the standard complexation/solvent extraction method which overcomes these difficulties without adding significantly to the time taken for analyses.
Resumo:
Through leaching experiments and simulated rainfall experiments, characteristics of vertical leaching of exogenous rare earth elements (REEs) and phosphorus (P) and their losses with surface runoff during simulated rainfall in different types of soils (terra nera soil, cinnamon soil, red soil, loess soil, and purple soil) were investigated. Results of the leaching experiments showed that vertical transports of REEs and P were relatively low, with transport depths less than 6 cm. The vertical leaching rates of REEs and P in the different soils followed the order of purple soil > terra nera soil > red soil > cinnamon soil > loess soil. Results of the simulated rainfall experiments (83 mm h(-1)) revealed that more than 92% of REEs and P transported with soil particles in runoff. The loss rates of REEs and P in surface runoff in the different soil types were in the order of loess soil > terra nera soil > cinnamon soil > red soil > purple soil. The total amounts of losses of REEs and P in runoff were significantly correlated.
Resumo:
Subspace learning is the process of finding a proper feature subspace and then projecting high-dimensional data onto the learned low-dimensional subspace. The projection operation requires many floating-point multiplications and additions, which makes the projection process computationally expensive. To tackle this problem, this paper proposes two simple-but-effective fast subspace learning and image projection methods, fast Haar transform (FHT) based principal component analysis and FHT based spectral regression discriminant analysis. The advantages of these two methods result from employing both the FHT for subspace learning and the integral vector for feature extraction. Experimental results on three face databases demonstrated their effectiveness and efficiency.
Resumo:
Amphetamines including methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxymethamphetamine were separated and detected by CE using simultaneous electrochemical (EC) and electrochemiluminescence (ECL) detection (CE-EC/ ECL). Factors that influenced the separation and detection performance, such as the detection potential, the pH value and concentration of the running buffer, the separation voltage and the pH of the detection buffer, were investigated.