192 resultados para Chromatography Mass-spectrometry
Resumo:
The effect of metal (Li+, Na+, K+, Ag+) cationization on collision-induced dissociation of ginsenosides was investigated by electrospray ionization mass spectrometry combined with multi-stage mass spectrometry (ESI-MSn). The fragments of sodiated and lithiated molecules give valuable structural information regarding the nature of the aglycone and the sequence and linkage information of sugar moieties. However, the number and relative abundances of fragment ions from lithiated ginsenosides are significantly greater than for the sodiated species, The K+ adducts undergo glycosidic cleavages and very limited cross-ring reactions. The silver ion adducts fragment mainly through glycosidic cleavages. Copyright (C) 2001 John Wiley & Sons, Ltd.
Resumo:
A method for the quantatitive determination of pethidine in human urine by liquid secondary ion and tandem mass spectrometry is presented. Quantification was carried out by using ketamine as internal standard. It was found that the collision-induced dissociation (CID) spectrum of the [M + H](+) ion of pethidine exhibited a prominent daughter ion at mit 220 and ketamine also yielded the same daughter ion at nit 220, For ((quadrupole)) quantitative analysis, the first quadrupole mass filter was set to transmit mit 220 and a narrow-range magnet scan yielded a spectrum of parents, including mit 238 and 248, corresponding to ketamine and pethidine, respectively. Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
In the present paper a study of C-19-diterpene type of aconitum alkaloids, extracted from aconite roots in Aconitum carmichaeli Debx has been made using matrix-assisted laser desorption/ionization time of Eight mass spectrometry (MALDI-TOFMS), The results demonstrated that the aconitum alkaloids from aconite roots can be determined simultaneously by this method, which was found to be superior to other analytical methods with regard to speed and sensitivity. Fourteen known aconitum alkaloids, including aconitines, benzoylaconitines and lipoaconitines, were assigned in the methanol extract and three compounds not reported before have been targeted separation. The evaluation of the efficiency of different extractions has been studied. These results suggested that the differences of the polarity and basicity of aconitine, and benzoylaconitines and lipoaconitines result from the C-8 constituent groups that are easily lost under MALDI, (C) 1998 John Wiley & Sons, Ltd.
Resumo:
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) of oligosaccharides and polysaccharides has been investigated in detail, It is demonstrated that cationized species of oligosaccharides, [M+Na](+) and [M+K](+), are dominant products under the MALDI condition, and negative ions of oligosaccharides are not formed to any significant extent in this process, The molecular masses of polysaccharides are similarly determined by positive- and negative-ion MALDI-MS with the help of column chromatography. The distinction between positive- and negative-ion MALDI mass spectra of oligo-and polysaccharides indicates that the MALDI processes for saccharides vary with molecular mass. The matrix plays a more important role in the ionization process for oligosaccharides, while in the desorption process for polysaccharides. (C) 1998 John Wiley & Sons, Ltd.
Resumo:
It is found that the nitro substituent of some aromatic bifunctional compounds shows unusual reactivity towards protonation. In the chemical ionization mass spectra of nitrobenzoic acids and their esters and amides, and of nitrophenols and their ethers, protonations on the carboxyl, ester, amide, hydroxyl or alkoxyl groups are highly suppressed by that on the nitro group. As a result, fragmentations based on protonation on these groups unexpectedly become negligible. Ortho effects were observed for all the ortho isomers where the initial protonation on the nitro group is followed by an intramolecular proton transfer reaction, which leads to the expected 'normal' fragmentations. Protonation on the nitro substituent is much more favourable in energy than on any of the other substituents. The interaction of the two substituents through the conjugating benzene ring is found to be responsible for this 'unfair' competitive protonation. The electron-attracting nitro group strongly destabilizes the MH+ ions formed through protonation on the other substituent; although the COR (R = OH, OMe, OEt, NH2) groups are also electron-withdrawing, their effects are weaker than that of NO2; thus protonation on the latter group produces more-stable MH+ ions. On the other hand, an electron-releasing group OR (R = H, Me, Et) stabilizes the nitro-protonated species; the stronger the electron-donating effect of this group the more stable the nitro-protonated ions.
Resumo:
A pre-column derivatization method for the sensitive determination of aliphatic amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-ethyl chloroformate (BCEOC) followed by HPLC with fluorescence detection and APCI/NIS identification in positive-ion mode has been developed. The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent was replaced by the 1,2-benzo-3,4-dihydrocarbazole functional group, which resulted in a sensitive fluorescence derivatizing reagent, BCEOC, that could easily and quickly label amines. Derivatives were stable enough to be efficiently analyzed by HPLC and showed an intense protonated molecular ion corresponding m/z [M + H](+) with APCI/MS in positive-ion mode. The collision induced dissociation of the protonated molecular ion formed characteristic fragment ions at m/z 264.1, m/z 246.0 and m/z 218.1, corresponding to the cleavages of CH2CH2O-CO, CH2CH2-OCO, and N-CH2CH2O bonds. Studies on derivatization conditions demonstrated that excellent derivatization yields close to 100% were observed with a 3 to 4-fold molar reagent excess in acetonitrile solvent, in the presence of borate buffer (pH 9.0) at 40 degrees C for 10 min. In addition, the detection responses for BCEOC derivatives were compared with those obtained with CEOC and FMOC as labeling reagents. The ratios I-BCEOC/I-CEOC and I-BCEOC/I-FMOC were, respectively, 1.40-2.76 and 1.36-2.92 for fluorescence responses (here, I was the relative fluorescence intensity). Separation of the amine derivatives had been optimized on an Eclipse XDB-C-8 column. Detection limits calculated from an 0.10 pmol injection, at a signal-to-noise ratio of 3, were 18.65-38.82 fmol (injection volume 10 mu L for fluorescence detection. The relative standard deviations for intraday determination (n = 6) of standard amine derivatives (50 pmol) were 0.0063-0.037% for retention times and 3.36-6.93% for peak areas. The mean intra-and inter-assay precision for all amines were <5.4% and 5.8%, respectively. The recoveries of amines ranged from 96 to 113%. Excellent linear responses were observed with correlation coefficients of >0.9994. The established method provided a simple and highly sensitive technique for the quantitative analysis of trace amounts of aliphatic amines from biological and natural environmental samples.
Resumo:
A sensitive method for the determination of 30 kinds of free fatty acids (FFAs, C-1-C-30) with 1-[2-(p-toluenesulfonate)-ethyl]-2-phenylimidazole-[4,5-f] 9,10-phenan- threne (TSPP) as labeling reagent and using high performance liquid chromatography with fluorescence detection and identification by online postcolumn mass spectrometry with atmospheric pressure chemical ionization (APCI) source in positive-ion mode (HPLC/MS/APCI) has been developed. TSPP could easily and quickly label FFAs in the presence of K2CO3 catalyst at 90 degrees C for 30 min in N,N-dimethylformamide (DMF) solvent, and maximal labeling yields close to 100% were observed with a 5-fold excess of molar reagent. Derivatives were stable enough to be efficiently analyzed by high performance liquid chromatography. TSPP was introduced into fatty acid molecules and effectively augmented MS ionization of fatty acid derivatives and led to regular MS and MS/MS information. The collision induced cleavage of protonated molecular ions formed specific fragment ions at m/z [MH](+)(molecular ion), m/z [M'+CH2CH2](+)(M' was molecular mass of the corresponding FFA) and m/z 295.0 (the, mass of protonated molecular core structure of TSPP). Fatty acid derivatives were separated on a reversed-phase Eclipse XDB-C-8 column (4.6 x 150 mm, 5 mu m, Agilent) with a good baseline resolution in combination with a gradient elution. Linear ranges of 30 FFAs are 2.441 x 10(-3) to 20 mu mol/L, detection limits are 3.24 similar to 36.97 fmol (injection volume 10 mu L, at a signal-to-noise ratio of 3, S/N 3:1). The mean interday precision ranged from 93.4 to 106.2% with the largest mean coefficients of variation (R.S.D.) < 7,5%. The mean intraday precision for all standards was < 6.4% of the expected concentration. Excellent linear responses were observed with correlation coefficients of > 0.9991. Good compositional data could be obtained from the analysis of extracted fatty acids from as little as 200 mg of bryophyte plant samples.Therefore, the facile TSPP derivatization coupled with HPLC/MS/APCI analysis allowed the development of a highly sensitive method for the quantitation of trace levels of short and long chain fatty acids from biological and natural environmental samples.
Resumo:
A macro matrix solid-phase dispersion (MSPD) method was developed to extract 266 pesticides from apple juice samples prior to gas chromatography-mass selective detection (GC-MSD) determination. A 10 g samples was mixed with 20 g diatomaceous earth. The mixture was transferred into a glass column. Pesticide residues were leached with a 160 mL hexane-dichloromethane (1:1) at 5 mL/min. Two hundred and sixty-six pesticides were divided into three groups and detected by GC-MSD under selective ion monitoring. The proposed method takes advantage of both liquid-liquid extraction and conventional MSPD methods. Application was illustrated by the analysis of 236 apple juice samples produced in Shaanxi province China mainland this year. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Desorption/ionization on silicon mass spectrometry (DIOS-MS) is a matrix-free technique that allows for the direct desorption/ionization of low-molecular-weight compounds with little or no fragmentation of analytes. This technique has a relatively high tolerance for contaminants commonly found in biological samples. DIOS-MS has been applied to determine the activity of immobilized enzymes on the porous silicon surface. Enzyme activities were also monitored with the addition of a competitive inhibitor in the substrate solution. It is demonstrated that this method can be applied to the screening of enzyme inhibitors. Furthermore, a method for peptide mapping analysis by in situ digestion of proteins on the porous silicon surface modified by trypsin, combined with matrix-assisted laser desorption/ionization-time of flight-MS has been developed.
Carbon Nanotubes as Assisted Matrix for laser Desorption/Lonization Time-of-Flight Mass Spectrometry