423 resultados para 10-1
Resumo:
Density functional theory (DFT) calculations were employed to explore the gas-sensing mechanisms of zinc oxide (ZnO) with surface reconstruction taken into consideration. Mix-terminated (10 (1) over bar0) ZnO surfaces were examined. By simulating the adsorption process of various gases, i.e., H-2, NH3, CO, and ethanol (C2H5OH) gases, on the ZnO (10 (1) over bar0) surface, the changes of configuration and electronic structure were compared. Based on these calculations, two gas-sensing mechanisms were proposed and revealed that both surface reconstruction and charge transfer result in a change of electronic conductance of ZnO. Also, the calculations were compared with existing experiments.
Resumo:
The dynamic interaction processes between a nano-second laser pulse and a gas-puff target, such as those of plasma formation, laser heating, and x-ray emission, have been investigated quantitatively. Time and space-resolved x-ray and optical measurement techniques were used in order to investigate time-resolved laser absorption and subsequent x-ray generation. Efficient absorption of the incident laser energy into the gas-puff target of 17%, 12%, 38%, and 91% for neon, argon, krypton, and xenon, respectively, was shown experimentally. It was found that the laser absorption starts and, simultaneously, soft x-ray emission occurs. The soft x-ray lasts much longer than the laser pulse due to the recombination. Temporal evolution of the soft x-ray emission region was analyzed by comparing the experimental results to the results of the model calculation, in which the laser light propagation through a gas-puff plasma was taken into account. (C) 2003 American Institute of Physics.
Resumo:
为了有效地补偿激光二极管(LD)侧向抽运1000 Hz重复率电光调Q Nd:YAG激光器棒状增益介质内存在的热致双折射损耗,设计了一种新颖的双调Q晶体开关复合谐振腔结构。实验结果表明,设计的双调Q晶体开关结构Nd:YAG激光器输出激光脉冲能量比单调Q晶体开关结构的非补偿腔输出能量提高了56%,当侧面抽运半导体激光器输出功率达到450 W时,激光输出达到30 mJ/pulse,输出光束偏振度优于10:1,激光脉冲宽度约14 ns。并获得6.7%的光-光转换效率。通过对双调Q开光激光谐振腔进行建模,并用求解速
Resumo:
A novel laser resonator for compensating depolarization loss that is due to thermally induced birefringence in active rod is reported. As this new structure being applied to an electro-optic Q-switched LIDA side-pumped Nd:YAG laser operating at a repetition rate of 1000 Hz, substantial reduction in depolarization loss has been observed, the output pulse energy is improved about 56% from that of a traditional resonator without compensation structure. With incident pump energy of 450 mJ per pulse, linearly polarized output energy of 30 mJ per pulse is achieved, the pulse duration is less than 15 ns, and the peak power of pulse is about 2 MW. The extinction ratio of laser beam is better than 10:1, and the beam divergence is 1.3 mrad with beam diameter of around 2.5 mm. (c) 2006 Published by Elsevier B.V.
Resumo:
The FOB-3, anew type fiber optic biosensor, is designed to rapidly detect a variety of biological agents or analytes with better stability, sensitivity and specificity. In order to detect Y. Pestis, a sandwich immunoassay was developed by using the purified antibody against antigen FI immobilized on polystyrene probes as the capture antibody and the monoclonal antibody-Cy5 conjugate as the detector. After a series of optimization for the stability, sensitivity and specificity of the FOB-3, 50-1000 ng/ml of antigen FI and 6 x 10(1)-6 x 10(7) CFU/ml Y. pestis could be detected constantly in about 20 min, and Y pestis could be detected specifically from Y. pseudotuberculosis, Y. enterocolitica, B. anthracis and E. coli. Then, 39 blind samples, including 27 tissues of mice infected with Y pestis and 12 tissues of healthy mice as negative control, were detected with the FOB-3. 92.6% infected tissues were identified from the tissues of healthy mice and the tissues containing more than 100 CFU/ml bacteria could be detected by the biosensor. The results demonstrated the feasibility of the FOB-3 as an effective method to detect Y. pestis rapidly and directly from the infected animal specimens with the advantage of portability, simple-operation as well as high sensitivity and specificity. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
本装置参照人工气候室原理加上可控有毒气体,在国内首次自行设计、安装调试而成,主要用于抗性、净化、指示植物筛选试验研究,不加毒气可作一般人工气候箱应用。本装置由双层玻璃室、内外环恒降温系统、净化、配气及检测等8部分组成。装置内采用自然光,为自然光照的50%-60%,自然光照在10万勒克斯以下时,可控温在低于最高温5℃内,精度±0.5℃;在10万勒克斯以上时,控温会出现超标1-2℃;相对湿度75%时,±10%;可控毒气浓度相对标准误差为5%,室内空间均匀度相对标准误差为18%。本装置适用于二氧化硫、氯气等对玻璃无腐蚀性的有毒气体试验,已投入试验多年,进行了二氧化硫、氯气两种气体、100多种植物试验,并取得良好试验效果。