609 resultados para Insulating silica capillary tubes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular diagnosis is playing an increasingly important role in the rapid detection and identification of pathogenic organisms in clinical samples. The genetic variation of ribosomal genes in bacteria offers an alternative to culturing for the detection and identification of these organisms. Here 16S rRNA and 16S-23S rRNA spacer region genes were chosen as the amplified targets for single-strand conformation polymorphism (SSCP) and restriction fragment length polymorphism (RFLP) capillary electrophoresis analysis and bacterial identification. The multiple fluorescence based SSCP method for the 16S rRNA gene and the RFLP method for the 16S-23S rRNA spacer region gene were developed and applied to the identification of pathogenic bacteria in clinical samples, in which home-made short-chained linear polyacrylamide (LPA) was used as a sieving matrix; a higher sieving capability and shorter analysis time were achieved than with a commercial sieving matrix because of the simplified template preparation procedure. A set of 270 pathogenic bacteria representing 34 species in 14 genera were analyzed, and a total of 34 unique SSCP patterns representing 34 different pathogenic bacterial species were determined. Based on the use of machine code to represent peak patterns developed in this paper, the identification of bacterial species becomes much easier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined detection system of simultaneous contactless conductometric and fluorescent detection for capillary electrophoresis (CE) has been designed and evaluated. The two processes share a common detection cell. A blue light-emitting diode (LED) was used as the excitation source and an optical fiber was used to collect the emitting fluorescence for fluorescent detection (FD). Inorganic ions, fluorescein isothiocyanate (FITC)-labeled amino acids and small molecule peptides were separated and detected by the combined detector, and the detection limits (LODs) of sub-μ M level were achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silica-supported Rh catalysts with different Rh particle dimensions were investigated for CO hydrogenation. The catalysts were characterized by various techniques such as TEM, H-2-TPR and N-2 adsorption to study the catalyst morphology, the size distributions of Rh particles and the silica pores. It was found that the distribution and the size of Rh particles were affected by the silica pores, and the metal grains were enclosed in the pores of the support, and thereby their growth was limited. The catalytic activity and selectivity to C-2-oxygenates for CO hydrogenation were found to be significantly controlled by the Rh particle sizes, and the higher activity and selectivity to C2-oxygenates were obtained over bigger Rh particles, within the range of the reported particle sizes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A capillary zone electrophoresis (CZE) method has been developed for investigating the physicochemical characteristics of five Strychnos alkaloids in Strychnos nux-vomica L. Firstly, the dissociation constants of the five Strychnos alkaloids were determined, based on the relation between the effective mobility of the solutes and the buffer pH. The mathematical relationship was strictly deduced from the fundamental electrophoretic theory and the dissociation equilibrium. Secondly, an equation describing the relation between the migration time of alkaloids of similar structure and their molecular weights was developed and used to predict the migration order and to calculate the electrosomotic velocity. The results predicted by the theory agreed with those from experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One asymmetric transformation reaction Of L-proline (L-Pro) to D-proline was studied by a home-made capillary array electrophoresis (CAE) for the first time. The aldehyde catalysts and the organic acid solvents for the asymmetric transformation reaction were rapidly screened and the enantiomeric excess values of the asymmetric product Of L-Pro were directly obtained from the electrophoretogram of CAE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for determining of heavy metal ions by field-amplified sample injection capillary electrophoresis with contactless conductivity detection. The effects of the 2-N-morpholinoethanesulfonic acid/histidine (MES/His) concentration in the sample matrix, the injection time and organic additives on the enrichment factor were studied. The results showed that MES/His with a low concentration in the sample matrix, an increase of the injection time and the addition of acetonitrile improved the enrichment factor. Four heavy metal ions (Zn2+, Co2+, Cu2+ and Ni2+) were dissolved in deionized water, separated in a 10 mM MES/His running buffer at pH 4.9 and detected by contactless conductivity detection. The detection sensitivity was enhanced by about three orders of magnitude with respect to the non-stacking injection mode. The limits of detection were in the range from 5 nM (Zn2+) to 30 nM (Cu2+). The method has been used to determine heavy metal ions in tap water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An interface of chip-based capillary electrophoresis (CE)-inductively coupled plasma-atomic emission spectrometry (ICP-AES) that is based on cross-flow nebulization has been developed. A polydimethylsiloxane (PDMS) CE-chip with conventional cross channel layout was used. A stainless steel tube was placed orthogonal to the exit of the CE separation channel for cross flow nebulization. A supplementary flow of buffer solution at the channel exit was used to improve nebulization efficiency. Two capillaries were inserted into the CE chip near the inlet of the separation channel for sample and buffer solution injection. Syringe pumps were used to manipulate the flow rate and flow direction of the sample, buffer, and supplementary buffer solution. Peak broadening due to the shape (bulb and tube-shaped) and size of the spray chambers was studied. The smaller tube-shaped spray chamber was used because of smaller peak broadening effect due to aerosol transport. The nebulization and transport efficiency of the CE-ICP interface was approximately 10%. Ba2+ and Mg2+ ions were eluted from the CE-chip within 30 s. Resolution of the Ba2+ and Mg2+ peaks was 0.7 using the chip-based CE-ICP-AES system.