54 resultados para refreshment samples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the specific property of respective phases in copper ore, optimal extracting condition for, tour phases of copper with five infusion was examined. After a series of experiments, for example, different weight Of sample, artificial mixed single phases sample and repeated experiment, the extracting ratio constants foil all phases in different infusions were obtained. The mathematical model which is on the basis of the stable extracting constant is established. Based on the purpose-control genetic algorithms, we only need to determine the total copper in the sample in different infusions under the selected condition, then the value of respective phase could be calculated. The-relative standard deviation are (%) free oxidized copper phase:1.5, conjunction oxidized copper phase: 17.6,, secondary copper sulfide phase: 1.9, primary copper sulfide phase : 2.7,total copper: 0.8.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) at different temperature programs. Their retention behaviours are predicted on the basis of an identification database of retention values (A, B) of gas chromatography. By the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retentions of all PCDDs and PCDFs can be calculated. After comparison with the retentions of practical environmental samples, the predicted values have been proved to be very accurate. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for environmental analysis has been mainly focused on qualitative analysis of high-mass molecules, such as toxins, humic acid, and microorganisms. Herein,we describe a novel MALDI-TOF-MS method with a matrix of oxidized carbon nanotubes for analysis of low-mass compounds in environmental samples. A number of chemicals in the environment were qualitatively analyzed by the present method, and it was found that most of them, especially the highly polar chemicals, were measurable with high sensitivity. With the intrinsic ability to measure high-mass chemicals, this method can compensate for the current shortage of methods for environmental analysis for the measurement of highly polar or high-mass chemicals. For sample analysis, arsenic speciation in Chinese traditional medicines was qualified and diphenylolpropane in water samples was quantified. With the relatively high tolerance of the method to interfering molecules, a simple pretreatment or even no pretreatment could be employed before MS detection. Furthermore, this method can be employed in a high-throughput format.