50 resultados para Tobacco consumption
Resumo:
In this paper, the fabrication method of a new type of carbon monoxide gas sensor based on SnOx with low power consumption and its sensing characteristics have been reported. The electric conductance of this type of sensor evolves oscillation form regularly when the sensor is exposed to low level of CO gas. The oscillation amplitude is directly proportional to the concentration of CO gas over a wide range. The effects of relevant factors. such as. humidity, temperature and interference gases on the sensor properties were examined. The sensing oscillation response mechanism was also discussed.
Resumo:
To investigate the effects of body size and water temperature on feeding and growth in the sea cucumber Apostichopus japonicus (Selenka), the maximum rate of food consumption in terms of energy (C-maxe; J day(-1)) and the specific growth rate in terms of energy (SGRe; % day(-1)) in animals of three body sizes (mean +/- SE) - large (134.0 +/- 3.5 g), medium (73.6 +/- 2.2 g) and small (36.5 +/- 1.2 g) - were determined at water temperatures of 10, 15, 20, 25 and 30 degrees C. Maximum rate of food consumption in terms of energy increased and SGRe decreased with increasing body weight at 10, 15 and 20 degrees C. This trend, however, was not apparent at 25 and 30 degrees C, which could be influenced by aestivation. High water temperatures (above 20 degrees C) were disadvantageous to feeding and growth of this animal; SGRe of A. japonicus during aestivation was negative. The optimum temperatures for food consumption and for growth were similar and were between 14 and 15 degrees C, and body size seemed to have a slight effect on the optimal temperature for food consumption or growth. Because aestivation of A. japonicus was temperature dependent, the present paper also documented the threshold temperatures to aestivation as indicated by feeding cessation. Deduced from daily food consumption of individuals, the threshold temperature to aestivation for large and medium animals (73.3-139.3 g) was 24.5-25.5 degrees C, while that for small animals (28.9-40.7 g) was between 25.5 and 30.5 degrees C. These values are higher than previous reports; differences in sign of aestivation, experimental condition and dwelling district of test animals could be the reasons.
Resumo:
PASSIM卷接机组原控制系统采用电路板进行逻辑控制,抗干扰性能差,故障率高,造成生产效率降低、原材料消耗增大、维修工作繁重等。为此,设计了一套新型卷接机组电气控制系统。该系统采用PLC进行过程控制,以工控机为上位机完成人机通信,采用交流伺服驱动,并通过高速信号处理专用系统完成重量检测控制及烟支质量检测功能;利用PROFIBUS、CAN及MPI多种总线方式完成各单元间的通讯,实现信号和数据间的传递和共享。改进后的PASSIM机组运行稳定可靠,采样速度快,实时性强,且维修方便。机组的有效作业率由85%左右提高到90%以上,降低了卷烟纸和烟丝等原材料的消耗。
Resumo:
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GUMS)and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC x GC/TOFMS), respectively. In the GUMS analysis, serially coupled columns were used. By comparing the GUMS results with GC x GC/TOFMS result,,, many more components in the essential oil could be found within the two-dimensional separation space of GC x GC. The quantitative determination of components in the essential oil was performed by GC x GC with flame ionization detection (FID), using a method of multiple internal standards calibration, (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
A quantitative analysis of the individual compounds in tobacco essential oils is performed by comprehensive two-dimensional gas chromatography (GC x GC) combined with flame ionization detector (FID). A time-of-flight mass spectrometer (TOF/MS) was coupled to GC x GC for the identification of the resolved peaks. The response of a flame ionization detector to different compound classes was calibrated using multiple internal standards. In total, 172 compounds were identified with good match and 61 compounds with high probability value were reliably quantified. For comparative purposes, the essential oil sample was also quantified by one-dimensional gas chromatography-mass spectrometry (GC/MS) with multiple internal standards method. The results showed that there was close agreement between the two analysis methods when the peak purity and match quality in one-dimensional GC/MS are high enough. (c) 2005 Elsevier B.V. All rights reserved.