112 resultados para Solid Phase Extraction
Resumo:
Superconductor mixed oxides are often used as catalysts at high temperature in gas-solid phase oxidations and considered not suitable for lower temperature reactions in the liquid-solid phase; here the catalysis of La2-xSrxCuO4+/-lambda (x = 0, 0.1, 0.7, 1) mixed oxides in phenol hydroxylation at lower temperatures are studied, and we find that the value of x has a significant effect on catalytic activity: the lower its value, the higher the catalytic activity; a mechanism is proposed to explain the experimental phenomena.
Resumo:
Aim: To study the pharmacokinetics of sifuvirtide, a novel anti-human immunodeficiency virus (HIV) peptide, in monkeys and to compare the inhibitory concentrations of sifuvirtide and enfuvirtide on HIV-1-infected-cell fusion. Methods: Monkeys received 1.2 mg/kg iv or sc of sifuvirtide. An on-line solid-phase extraction procedure combined with liquid chromatography tandem mass spectrometry (SPELC/MS/MS) was established and applied to determine the concentration of sifuvirtide in monkey plasma. A four-I-127 iodinated peptide was used as an internal standard. Fifty percent inhibitory concentration (IC50) of sifuvirtide on cell fusion was determined by co-cultivation assay. Results: The assay was validated with good precision and accuracy. The calibration curve for sifuvirtide in plasma was linear over a range of 4.88-5000 mu g/L, with correlation coefficients above 0.9923. After iv or sc administration, the observed peak concentrations of sifuvirtide were 10626 +/- 2886 mu g/L and 528 +/- 191 mu g/L, and the terminal elimination half-lives (T,12) were 6.3 +/- 0.9 h and 5.5 +/- 1.0 h, respectively. After sc, T-max was 0.25-2 h, and the absolute bioavailability was 49% +/- 13%. Sifuvirtide inhibited the syncytium formation between HIV-1 chronically infected cells and uninfected cells with an IC50 of 0.33 mu g/L. Conclusion: An on-line SPE-LC/MS/MS approach was established for peptide pharmacokinetic studies. Sifuvirtide was rapidly absorbed subcutaneously into the blood circulation. The T-1/2 of sifuvirtide was remarkably longer than that of its analog, enfuvirtide, reported in healthy monkeys and it conferred a long-term plasma concentration level which was higher than its IC50 in vitro.
Resumo:
To characterize the contamination of anthropogenic organic contaminants in the aquatic environment of Chaohu Lake, China, 7 samples for both water and surface sediment were collected in the lake. Organic contaminants were extracted by solid phase extraction (SPE) and Soxhlet extraction from the water and surface sediment samples, respectively, and then analyzed by GC-MS. One hundred and twenty kinds of organic chemicals were detected in these samples including phenol, benzene series, benzaldehydes, ethanol, polycyclic aromatic hydrocarbons (PAHs), sulfur compounds, alcoholic halides, amines, ketones, esters, alkenes and alkanes. Among them, 13 kinds of chemicals were identified as priority pollutants listed by the U.S. Environmental Protection Agency (EPA), such as phthalate esters (PAEs) and PAHs. Besides, the concentrations of 19 of PAEs and PAHs including, priority pollutants identified were also determined. Bis(2-ethylhexyl)phthalate, the predominant component of the analyzed pollutants, was in the range from 72.34 ng g(-1) DW to 613.71 ng g(-1) DW, 14.80 ng L-1 to 47.05 ng L-1 in sediment and water, respectively. The results indicated that the northwest part of the lake was heavily polluted by domestic and industrial wastewater.
Resumo:
A rapid and sensitive method was developed and validated for the determination of MCYST (microcystin)-RR, -LR, and [Dha(7)] MCYST-LR in rat plasma by liquid chromatography-tandem mass spectrometry. The analytes were extracted from rat plasma by protein precipitation, followed by solid-phase extraction. Liquid chromatography with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MCYST-RR, -LR, and [Dha(7)] MCYST-LR in rat plasma. The recoveries for each analyte in rat plasma ranged from 70.8 to 88.7%. The calibration curve was linear within the range from 0.005 to 1.25 mu g mL(-1). The limit of detection were 1.4, 1.0, 0.6 ng mL(-1) for MCYST-RR, -LR, and [Dha(7)] MCYST-LR. The overall precision was determined on three different days. The values for within- and between-day precision in rat plasma were within 15%. This method was applied to the identification and quantification of microcystins in rat plasma with acute exposure of microcystins via intravenous injection.
Resumo:
Gel filtration chromatography, ultra-filtration, and solid-phase extraction silica gel clean-up were evaluated for their ability to remove microcystins selectively from extracts of cyanobacteria Spirulina samples after using the reversed-phase octadecylsilyl ODS cartridge for subsequent analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The reversed-phase ODS cartridge/silica gel combination were effective and the optimal wash and elution conditions were: H2O (wash), 20% methanol in water (wash), and 90% methanol in water (elution) for the reversed-phase ODS cartridge, followed by 80% methanol in water elution in the silica gel cartridge. The presence of microcystins in 36 kinds of cyanobacteria Spirulina health food samples obtained from various retail outlets in China were detected by LC-MS/MS, and 34 samples (94%) contained microcystins ranging from 2 to 163 ng g(-1) (mean=1427 ng g(-1)), which were significantly lower than microcystins present in blue green alga products previously reported. MC-RR-which contains two molecules of arginine (R)-(in 94.4% samples) was the predominant microcystin, followed by MC-LR-where L is leucine-(30.6%) and MC-YR-where Y is tyrose-(27.8%). The possible potential health risks from chronic exposure to microcystins from contaminated cyanobacteria Spirulina health food should not be ignored, even if the toxin concentrations were low. The method presented herein is proposed to detect microcystins present in commercial cyanobacteria Spirulina samples.
Resumo:
A sensitive and selective liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantitative determination of microcystin-LR (MC-LR) and its glutathione conjugate (MC-LR-GSH) in fish tissues. The analytes were extracted from fish liver and kidney using 0.01 M EDTA-Na-2-5% acetic acid, followed by a solid-phase extraction (SPE) on Oasis HLB and silica cartridges. High-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MC-LR and its glutathione conjugate in fish liver and kidney. Recoveries of analytes were assessed at three concentrations (0.2, 1.0, and 5 mu g g(-1) dry weight [DW]) and ranged from 91 to 103% for MC-LR, and from 65.0 to 75.7% for MC-LR-GSH. The assay was linear within the range from 0.02 to 5.0 mu g g(-1) DW, with a limit of quantification (LOQ) of 0.02 mu g g(-1) DW. The limit of detection (LOD) of the method was 0.007 mu g g(-1) DW in both fish liver and kidney. The overall precision was determined on three different days. The values for within- and between-day precision in liver and kidney were within 15%. This method was applied to the identification and quantification of MC-LR and its glutathione conjugate in liver and kidney of fish with acute exposure of MC-LR. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The ratio of methanol., water and trifluoroacetic acid ( TFA) was regulated to change the polarity and the pH of the rinse solution and the eluent, so as to improve the high performance liquid chromatography HPLC) detection method for trace microcystines (MCs) in natural water bodies. The results showed that 40 % similar to 45 % methanol-water solution containing 0. 1 % TFA could get good effects on the rinse of impurity, and 70% methanol-water solution containing 0. 1% TFA could elute all the MCs in solid phase extraction ( SPE) cartridge ( C-18), In this way. it is suggested that, in analysis of environmental samples with high concentration of impurity, impurity should be washed with 40% similar to 45% methanol-water solution containing 0. 1% TFA, and MCs should be eluted with 70% similar to 100% methanol-water solution containing 0. 1% TFA.
Resumo:
A preliminary survey was carried out in April 2003 to estimate the levels of nonylphenol (NP), bisphenol-A (BPA) and residual DDTs in Lake Donghu. After then, the sediments of some areas of the lake were moved out for clearing the lake by the local government. Therefore, the variance of NP and BPA after the clearance of sediment in the surface water was determined from December 2003 to May 2004. Sediments, surface water and fish were collected from four sub-lake areas and the analytes were qualified by GC/MS in SIM mode after concentration onto an Oasis solid phase extraction cartridge. NP and BPA values ranged between 5.46-119.10 and 0.9913.42 mg/kg dw, respectively, in sediments, 75.2-179.6 and 15.1-62.5 mu g/L in surface water. Meanwhile, the bioaccumulation factors (BCFs) of NP and BPA were calculated in fish livers. Plasma vitellogenin (VTG), a sensitive biomarker showing oestrogenicity was detected in the captured male Wuchang bream (Megalobrama amblycephala Yih) and common carp (Cyprinus carpio). After sediment clearance, the concentrations of NP and BPA decreased to 0.65-25.04 and 0.04-21.32 mu g/L. The results indicate the presence of high-dose xenoestrogenic NP and BPA, probably major contributors which associate with VTG induction in Lake Donghu male fish.
Resumo:
Organic pollutants, especially persistent organic pollutants were examined in the water and surface sediments of Taihu Lake, China. Both 12 water and 12 sediment samples were collected over the lake. C-18 solid-phase extraction technique was applied to extract organic pollutants in collected water samples. Soxhlet extraction procedure was used to extract organic pollutants in sediment samples. The analysis was performed by GC-MS controlled by a Hewlett Packard chemstation. Two hundred and seventy-three kinds of organic chemicals in water were examined, 200 more than that detected in 1985; 188 kinds of chemicals in sediments were detected as well. Among them 21 kinds of chemicals belong to priority pollutants as well as 17 kinds to be the endocrine disruptors. The concentrations of the pollutants were more than 2 times higher than that in 1985. The possible source and relation to anthropogenic activity were discussed. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
8-hydroxy-2'-deoxyguanosine (8OHdG) has been widely used as a biomarker of oxidative DNA damage in both animal models and human studies. To evaluate the effect of cigarette smoking on oxidative stress, we studied the levels of urinary 8OHdG from smokers and non-smokers and investigated the association with cigarette smoking. The urinary 8OHdG concentrations were determinated by capillary electrophoresis with end-column amprometric detection (CE-AD) after a single-step solid phase extraction (SPE), and then quantitatively expressed as a function of creatinine excretion. To increase the concentration sensitivity, a dynamic pH junction was used and the focusing effect was obvious when using 30 mM phosphate (pH 6.50) as sample matrix. The limit of detection is 4.3 nM (signal-to-noise ratio S/N = 3). The relative standard deviation (R.S.D.) was 1.1% for peak current, and 2.3% for migration time. Based on the selected CE-AD method, it was found that the mean value of urinary 8OHdG levels in the smokers significantly higher than that in non-smokers (31.4 +/- 18.9 nM versus 14.4 +/- 7.6 nM, P = 0.0004; 23.5 +/- 21.3 mug g(-1) creatinine versus 12.6 +/- 13.2 mug g(-1) creatinine, P = 0.028). (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Increased oxidative stress induced by hyperglycemia may contribute to the pathogenesis of diabetic complications. Urinary 8-hydroxydeoxyguanosine (8-OHdG) has been reported to serve as a sensitive biomarker of oxidative DNA damage and also of oxidative stress. This article studied oxidative DNA damage in patients with diabetic nephropathy and in healthy control subjects by urinary 8-OHdG evaluations. Contents of 8-OHdG in urine were analyzed by capillary electrophoresis with end-column amperometric detection (CE-AD) after a single-step solid-phase extraction (SPE). Levels of urinary 8-OHdG in diabetic nephropathy patients with macroalbuminuria was significant higher than in control subjects (5.72 +/- 6.89 mumol/mol creatinine versus 2.33 +/- 2.83 mumol/mol creatinine, P = 0.018). A significant difference of 24 h urinary 8-OHdG excretions exists between the patients with macroalbuminuria and the patients with nonnoalbuminuria (19.2 +/- 16.8 mug/24 h versus 8.1 +/- 1.7 mug/24 h, P = 0.015). There was a positive correlation between urinary excretion of 8-OHdG and glycosylated hemoglobin (HbA(1)c) (r = 0.287, P = 0.022). A weak correlation exists between the levels of 8-OHdG and triglyceride (r = 0.230, P = 0.074). However, the urinary 8-OHdG contents are not correlated with blood pressure and total cholesterol. The increased excretion of urinary 8-OHdG is seen as indicating an increased systemic level of oxidative DNA damage in diabetic nephropathy patients. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Melatonin is a highly conserved molecule that not only exists in animals, but also is present in bacteria, unicellular organisms and in plants. Since melatonin is an antioxidant, in plants melatonin was speculated to protect them from intrinsic and environmental oxidative stress. More importantly, melatonin in edible plants inevitably enters animals and human through feed and food. In this study, more than 100 Chinese medicinal herbs were analyzed using the methods of solid phase extraction and HPLC-FD on-line with MS to determine whether melatonin is present in these commonly used herbs. Melatonin was detected in majority of these plants. Sixty-four of them contain melatonin in excess of 10 ng per gram dry mass. Melatonin levels in several herbs are in excess of 1000 ng/g. It is well known that normal average physiological plasma levels of melatonin are only 10-60 pg/mL. These high level-melatonin containing plants are traditionally used to treat diseases which presumably involve free radical damage. The current study provides new information concerning one potentially effective constituent present in a large number of medicinal herbs. The results suggest that these herbs should be reevaluated in reference to their nutritional and medicinal value. (C) 2003 Elsevier Science Inc. All rights reserved.
Resumo:
A new approach for fast and sensitive electrochemiluminescence (ECL) detection of narcotic drugs on a microchip after separation by micellar electrokinetic chromatography (MEKC) is presented, taking the cocaine and its hydrolysate ecgonine as the test analytes. The mixture of hydrophilic BMIMBF4 ionic liquid (IL) and sodium dodecyl sulfate (SDS) was used directly as the buffer of MEKC with less noisy baselines, lower electrophoretic current and satisfactory separation performance.
Resumo:
CE/tris(2,2-bipyridyl) ruthenium(ll) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL), CEECL, with an ionic liquid (IL) detection system was established for the determination of bioactive constituents in Chinese traditional medicine opium poppy which contain large amounts of coexistent substances. A minimal sample pretreatment which involves a one-step extraction approach avoids both sample loss and environmental pollution. As the nearby hydroxyl groups in some alkaloid such as morphine may react with borate to form complexes and IL, as a high-conductivity additive in running buffer, could cause an enhanced field-amplified effect of electrokinetic injection. Running buffer containing 25 mM borax-8 mM 1-ethyl-3-methylimidazolium tetrafluoroborate (EMImBF(4)) IL (pH 9.18) was used which resulted in significant changes in separation selectivity and obvious enhancement in ECL intensities for those alkaloids with similar structures. Sensitive detection could be achieved when the distance between the Pt working electrode and the outlet of separation capillary was set at 150 mu m and the stainless steel cannula was fixed approximately 1 cm away from the outlet of the capillary. Quantitative analysis of four alkaloids was achieved at a detection voltage of 1.2 V and a separation voltage of 15 kV in less than 7 min.
Resumo:
The fast analysis of ranitidine is of clinical importance in understanding its efficiency and a patient's treatment history. In this paper, a novel determination method for ranitidine based on capillary electrophoresis-electrochemiluminescence detection is described. The conditions affecting separation and detection were investigated in detail. End-column detection of ranitidine in 5 mM Ru(bpy)(3)(2+) solution at applied voltage of 1.20 V was performed. Favorable ECL intensity with higher column efficiency was achieved by electrokinetic injection for 10 s at 10 kV. The R.S.D. values of ECL intensity and migration time were 6.38 and 1.84% for 10(-4) M and 6.01 and 0.60% for 10(-5) M, respectively. A detection limit of 7 x 10(-8) M (S/N = 3) was achieved. The proposed method was applied satisfactorily to the determination of ranitidine in urine in 6 min.