154 resultados para ION TRANSFER KINETICS


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The transfer behavior of the heteropoly anion [H3PW11O39]4- and the isopoly anion [H2W12O39]4- across the water/nitrobenzene interface was investigated by cyclic voltammetry and chronopotentiometry with linear current scanning. The transfer processes were

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Lidocaine transfer across the water/1,2-dichloroethane and the water/nitrobenzene interfaces has been investigated by chronopotentiometry with linear current scanning and cyclic voltammetry. The irreversible hydrolysis occurring in the phase transfer of dicaine at the water/nitrobenzene interface is discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

I. INTRODUCTIONStudies on the electrochemical phenomena at the liquid-liquid interface are a developing area in electrochemistry and electroanalytical chemistry. The exploration for new ion transfer systems is very important in the development of this area. Dyes are a large group of reagents used widely in analytical chemistry. But no paper deals with the tran,fer processes of dyes at the liquid-liquid (L/L) interface so far.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

液/液界面通常被看作是人工膜和生物膜的简单模型,液界面电分析化学的主要研究对象是界面上的电荷(电子和离子)转移反应以及伴随发生的相关化学反应。本论文简要回顾了液/液界面电分析化学的发展历程,介绍了液/液界面上电分析化学的基本理论。目前,应用扫描电化学显微镜结合微、纳米电极技术研究液/液界面上的电荷转移反应是电分析化学领域的研究热点之一。本文在本实验室以往研究工作的基础上,将扫描电化学显微镜、微、纳米管技术和各种电化学方法相结合,一方面进一步深入研究了在可极化液/液界面上、高驱动力作用下的加速离子转移反应的动力学,另一方面探讨了支持电解质浓度对简单及加速离子在低离子强度溶液相间的转移反应的影响。主要结果如下:1.通过选择适当的研究模型(二苯基18冠6加速Na+、Li+在水1/2-二氯乙烷界面上的转移反应)、实验条件及将三电极系统、纳米管与扫描电化学显微镜相结合,进一步研究了加速离子转移反应的驱动力与异相反应速率常数之间的关系。由实验得到,加速离子转移反应的速率常数匆与反应驱动力直接相关。在低驱动力区,Inkf与驱动力的关系遵循经典的Butier~Voh“方程;高马时力区,反应的动力学逐渐进入Marcus翻转区,即反应的速率常数随驱动力的增加而减小,此与Marcus 理论相一致。本实验是第一次在加速离子转移反应中观察到Marcus翻转现象。2.应用循环伏安法、方波法、计时安培法和微/纳米管技术研究了加速钾离子从水相向高阻抗有泪毛相转移的反应。同时系统讨论了低浓度电解质对水相及有机相TMA~+简单离子转移反应的影响。实验中绷门发现纳米管可被用子有机相无外加支持电解质的加速离子转移反应的研究。而在含少量或不含电解质的两相间的TMA+离子转移反应中,可以清楚的观察到迁移在TMA+转移过程中所起的作用。另外也较详细讨论了简单离子在界面转移的机理。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, the characterization and application of a chemically reduced graphene oxide modified glassy carbon (CR-GO/GC) electrode, a novel electrode system, for the preparation of electrochemical sensing and biosensing platform are proposed. Different kinds of important inorganic and organic electroactive compounds (i.e., probe molecule (potassium ferricyanide), free bases of DNA (guanine (G), adenine (A), thymine (T), and cytosine (C)), oxidase/dehydrogenase-related molecules (hydrogen peroxide (H2O2/beta-nicotinamide adenine dinucleotide (NADH)), neurotransmitters (dopamine (DA)), and other biological molecules (ascorbic acid (AA), uric acid (UA), and acetaminophen (APAP)) were employed to study their electrochemical responses at the CR-GO/GC electrode, which shows more favorable electron transfer kinetics than graphite modified glassy carbon (graphite/GC) and glassy carbon (GC) electrodes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Multiwall carbon nanotubes (CNTs)-modified electrode has been prepared by using ionic liquid (IL) as the binder. The as-prepared CNTs-IL composite modified electrode has good biocompatibility and is a suitable matrix to immobilize biomolecules. Glucose oxidase (GOx), containing flavin adenine dinucleotide as active site, stably adsorbed on modified electrode surface has resulted in the direct electron transfer. The electron transfer rate of 9.08 s(-1) obtained is much higher than that of GOx adsorbed on the CNTs papers (1.7 s(-1)), and the process is more reversible with small redox peak separation of 23 mV This may be due to the synergetic promotion of CNTs and IL to electron transfer of the protein, especially the IL as the binder, showing better electrochemical properties than that of chitosan and Nafion. Furthermore, GOx adsorbed at the modified electrode exhibits good stability and keeps good electrocatalytic activity to glucose with broad linear range up to 20 mM. Besides, the simple preparation procedure and easy renewability make the system a basis to investigate the electron transfer kinetics and biocatalytic performance of GOx and provide a promising platform for the development of biosensors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Calf thymus DNA was immobilized on functionalized glassy carbon, gold and quartz substrates, respectively, by the layer-by-layer (LBL) assembly method with a polycation QPVP-Os, a quaternized poly(4-vinylpyridine) partially complexed with osmium bis(2,2'-bipyridine) as counterions. UV-visible absorption and surface plasmon resonance spectroscopy (SPR) showed that the resulting film was uniform with the average thickness 3.4 nm for one bilayer. Cyclic voltammetry (CV) showed that the total surface coverage of the polycations increases as each QPVP-Os/DNA bilayer added to the electrode surface, but the surface formal potential of Os-centered redox reaction shifts negatively, which is mainly attributed to the intercalation of redox-active complex to DNA chain. The electron transfer kinetics of electroactive QPVP-Os in the multilayer film was investigated by electrochemical impedance experiment for the first time. The permeability of Fe(CN)(6)(3-) in the solution into the multilayer film depends on the number of bilayers in the film. It is worth noting that when the multilayer film is up to 4 bilayers, the CV curves of the multilayer films display the typical characteristic of a microelectrode array.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Single-walled carbon nanotubes (SWCNTs) as reinforcing components were extended into silica monoliths and thin films via covalent functionalization for the first time. Silica materials have poor mechanical attributes, which limit their applications. Because of the extreme flexibility of SWCNTs and their large interfacial area, they may be very intriguing as reinforcing fillers for the silica matrix. To get more uniform dispersion and stronger interfacial interaction, SWCNTs were covalently functionalized with silane, and then integrated into silica via a sol - gel process, and their properties were also compared with those of pristine SWCNTs. Results show that the silane-functionalized nanotubes resulted in better mechanical properties ( for example, 33% increase in stress, and 53% increase in toughness), as well as higher electron-transfer kinetics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gold nanoparticles were used to enhance the immobilization amount and retain the immunoactivity of recombinant dust mite allergen Der f2 immobilized on a glassy carbon electrode (GCE). The interaction between allergen and antibody was studied by electrochemical impedance spectroscopy (EIS). Self-assembled Au colloid layer (Phi = 16 nm) deposited on (3-mercaptopropyl)trimethoxysilane (MPTS)-modified GCE offered a basis to control the immobilization of allergen Der f2. The impedance measurements were based on the charge transfer kinetics of the [Fe(CN)(6)](3-/4-) redox pair, compared with bare GCE, the immobilization of allergen Der f2 and the allergen-antibody interaction that occurred on the electrode surface altered the interfacial electron transfer resistance and thereby slowed down the charge transfer kinetics by reducing the active area of the electrode or by preventing the redox species in electrolyte solution from approaching the electrode. The interactions of allergen with various concentrations of monoclonal antibody were also monitored through the change of impedance response. The results showed that the electron transfer resistance increased with increasing concentrations of monoclonal antibody.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel "bottom-up" approach to highly controllable nanoelectrode ensembles (NEEs) has been developed using colloidal nanoparticle self-assembly techniques. Ibis solution-based strategy allows flexible control over nanoelectrode size, shape, and interspacing of the as-prepared NEEs. Atomic force microscopy (AFM) was proved to be a powerful tool to monitor the NEE topography, which yields parameters that can be used to calculate the fractional nanoelectrode area of the NEEs. AFM, ac impedance, and cyclic voltammetry studies demonstrate that most of nanoelectrodes on the NEEs (at least by 9-min self-assembly) are not diffusionally isolated under conventional ac frequency range and scan rates. As a result, the NEEs behave as "nanoelectrode-patch" assemblies. Besides, the as-prepared NEEs by different self-assembling times show an adjustable sensitivity to heterogeneous electron-transfer kinetics, which may be helpful to sensor applications. Like these NEEs constructed by other techniques, the present NEEs prepared by chemical self-assembly also exhibit the enhancement of electroanalytical detection limit consistent with NEE theory prediction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The basic principle, instrumentation and recent advances of scanning electrochemical microscopy are briefly reviewed with 55 references.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel kind of electroactive self-assembled monolayer (SAM) has been successfully prepared through the following procedure: (1) formation of inclusion complexes (denoted as CD/C8VC10SH) between N-(n-octyl)-N'-(10-mercaptodecyl)-4,4'-bipyridinium dibromide (C8VC10SH) and alpha-, beta-cyclodextrin (CD) under a mild condition; (2) spontaneous formation of SAM of CD/C8VC10SH on gold electrodes at room temperature. High-resolution H-1-NMR spectrum was used to confirm the formation of CD/C8VC10SH. Cyclic voltammetry was used to characterize the redox behavior of the resulting monolayers and chronoamperometry and electrochemical impedance spectroscopy to characterize their electron transfer kinetics. It was found that the redox sites in SAM of CD/C8VC10SH are effectively diluted, with a larger electron transfer rate constant than that of SAM of C8VC10SH.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Applying impedance spectrum technique to liquid/liquid interfacial electrochemistry, we present the theoretical expression of the liquid/liquid interfacial impedance in the four - electrode electrolytic cell measured by alternating current impedance method. The influence of the electrolytic cell parameters and input passage parameters of the impedance apparatus on impedance spectrum curves are theoretically studied.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pyrazolone derivatives, such as antipyrine, aminopyrine, and 4-aminoantipyrine, can transfer across the water/nitrobenzene interface to produce a pair of well-defined symmetric, reversible anodic-cathodic peaks by cyclic voltammetri. The transfer mechanis

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of chemically modified electrodes (CMEs) for liquid chromatography and flow-injection analysis is reviewed. Electrochemical detection with CMEs based on electrocatalysis, permselectivity, ion flow in redox films, and ion transfer across the water-solidified nitrobenzene interface is discussed in terms of improving the stability, selectivity, and scope of electrochemical detectors, and the detection of electroinactive substances. More than 90 references are included.