414 resultados para Electrode position


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A third-order weighted essentially nonoscillatory and non-free-parameter difference scheme magnetohydrodynamic solver has been established to investigate the mechanisms of magnetohydrodynamics controlling separation induced by an oblique shock wave impinging on a flat plate. The effects of magnetohydrodynamic interaction-zone location on the separation point, reattachment point, separation-bubble size, and boundary-layer velocity profiles are analyzed. The results show that there exists a best location for the magnetohydrodynamic zone to be applied, where the separation point is delayed the farthest, and the separation bubble is decreased up to about 50% in size compared to the case without magnetohydrodynamic control, which demonstrated the promising of magnetohydrodynamics suppressing the separation induced by shock-wave/boundary-layer interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arc root behavior affects the energy transfer and nozzle erosion in an arcjet thruster. To investigate the development of arc root attachment in 1 kW class N2 and H2-N2 arcjet thrusters from the time of ignition to the stably working condition, a kinetic series of end-on view images of the nozzle obtained by a high-speed video camera was analyzed. The addition of hydrogen leads to higher arc voltage levels and the determining factor for the mode of arc root attachment was found to be the nozzle temperature. At lower nozzle temperatures, constricted type attachment with unstable motions of the arc root was observed, while a fully diffused and stable arc root was observed at elevated nozzle temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new non-linear comparison method of charge-division readout scheme is conceived and the first design of a multi-hit two-dimensional position-sensitive energy spectrum Si(Au) surface barrier detector with a continuous sensitive area is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-hit 3-layer delay-line anode (Hexanode) has an increased ability to detect multi-hit events in a collision experiment. Coupled with a pair of micro-channel plates, it can provide position information of the particles even if the particles arrive at the same time or within small time dwell. But it suffers from some ambiguous outputs and signal losses due to timing order and triggering thresholds etc. We have developed a signal reconstruction program to correct those events. After the program correction, the dead time only exists when 2 paxticles arrive at the same time and the same position within a much smaller range. With the combination of Hexanode and the program, the experimental efficiencies will be greatly improved in near threshold double ionization on He collisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

高效率的电子冷却过程,要求电子束与离子束位置平行且重叠。为了同时测量电子束与离子束的位置,在HIRFL-CSR电子冷却装置上研发了以容性圆筒形极板为感应电极的束流位置探测系统。系统测量束流通过探针时产生的脉冲感应信号,并进行傅里叶变换得到频谱信号,分析4个不同电极上频谱信号强度获取束流的位置信息。测量结果表明,该束流位置探测系统测量准确,为定量研究储存环离子累积和电子冷却过程与两种束流相对位置及角度的依赖关系提供了条件。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

针对高流强粒子束与绝缘毛细管相互作用的特点,设计制作了一套64通道一维位置灵敏电流分布探测器及其配套的数据获取系统,该探测器可分辨最小直径为1mm的束斑,通过数据获取系统可实现可视化自动数据采集。用2nA和200—2000eV电子对探测器进行了定标,并用10μA和2000eV的电子束穿越锥形毛细管后的出射电子,对探测器及数据获取系统进行测试,获得了出射粒子的位置分布谱及能量信息。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prototype of time-of-flight positron emission computed tomography (TOF-PET) has been developed for acquiring the coincident detection of 511 keV gamma-rays produced from positron annihilation. It consists of two 80.5 mmx80.5 mm LYSO scintillator arrays (composed of 35 x35 pixel finger crystals) with the position sensitive photomultiplier tubes R2487 as the readout. Each array is composed of 2 mm x2 mm x 15 mm finger crystals and the average pixel pitch is 2.30 mm. The measured results indicate that the TOF information has the potential to significantly enhance the image quality by improving the noise variance in the image reconstruction. The best spatial resolution (FWHM) of the prototype for the pairs of 511 keV gamma-rays is 1.98 mm and 2.16 mm in the x and y directions, respectively, which are smaller than the average pixel pitch of 2.30 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a laser ion source, plasma drift distance is one of the most important design parameters. Ion current density and beam pulse width are defined by plasma drift distance between a laser target and beam extraction position. In direct plasma injection scheme, which uses a laser ion source and a radio frequency quadrupole linac, we can apply relatively higher electric field at beam extraction due to the unique shape of a positively biased electrode. However, when we aim at very high current acceleration such as several tens of milliamperes, we observed mismatched beam extraction conditions. We tested three different ion current at ion extraction region by changing plasma drift distance to study better extraction condition. In this experiment, C6+ beam was accelerated. We confirmed that matching condition can be improved by controlling plasma drift distance.