101 resultados para Aerobic incubation at 4°C, gas chromatography
Resumo:
Polyurethane foam unit (PFU) systems were collected from 11 lakes and three rivers in the Yunnan Plateau, China and, the PFU extrusion liquids, were analyzed for organochlorine pesticides (OCPs) by gas chromatography with electron capture detection (GCECD). The concentrations of pp'-DDE, HCB and HCHs were undetectable to 1.86 mu g l(-1) (mean 0.27 mu g l(-1)), undetectable to 0.72 mu g l(-1) (mean 0.11 mu g l(-1)), and 0.24-21.95 mu g l(-1) (mean 7.39 mu g l(-1)) respectively in lakes; and those in rivers were undetectable to 0.23 mu g l(-1) (mean 0.08 mu g l(-1)), 0.68-2.93 mu g l(-1) (mean 1.70 mu g l(-1)), and 2.71-37.56 mu g l(-1) (mean 17.01 mu g l(-1)) respectively. Notably, some residue levels of OCPs exceeded the US National Recommended Water Quality Criteria, implying Yunnan has levels of OCPs potentially harmful to human health. Further, the contamination by OCPs showed an obvious spatial distribution pattern. Amongst the lakes, Dianchi, Xingyun, Lugu and Yangzonghai had the highest OCP levels dominated by beta-HCH, whereas among rivers, Nujiang and Lancang Rivers had the highest contents of OCPs dominated by alpha-HCH. This demonstrates that HCHs are the predominant contaminants and some point sources of HCHs may still exist in Yunnan. The pollution levels in Yunnan were compared with other studies, suggesting the PFU method is suitable for long-term on-line monitoring of trace OCPs in aquatic ecosystems. Therefore, continuous studies monitoring OCPs in lakes and rivers are needed to further understand the future trend of contamination. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This study investigates the ozonation of 17 alpha-ethinylestradiol (EE2) in aqueous solution. The affecting factors on the degradation of EE2 were studied and described in details, such as initial EE2 concentration, initial pH value and ozone concentration. In addition, some parameters such as pH. electrical conductivity, mineralization efficiency and degradation products were monitored during the process. The mineralization efficiency of EE2 could reach 53.9%. During the ozonation process the rapid decrease of pH and the sharp increase of electrical conductivity indicated the fort-nation of acidic by-products, small fragments and ions which were confirmed by high performance liquid chromatography (HPLC) and gas chromatography-mass spectrometry (GUMS) analysis. Results showed that there were intermediate products of smaller molecule with higher polarity produced during the course of EE2 degradation. Then a possible reaction pathway for EE2 degradation involving all intermediates detected is proposed. During the ozonation process EE2 was first oxidized into hydroxyl-semiquinone isomers which were subsequently degraded into low molecular weight compounds such as oxalic acid, malonate, glutarate, and so on. Furthermore. these organic acids are easily oxidized by ozone into carbon dioxide (CO2). This work shows that ozonation process is promising for the removal of EE2. The results can provide some useful information for the potential treatment of EE2 by ozonation in aqueous solution. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
A novel fiber coated with novel sol-gel (5,11,17,23-tetra-tert-butyl-25,27-dihydroxy-26,28-diglycidyloxycalix[4]arene/hydroxy-terminated silicone oil; diglycidyloxy-C[4]/OH-TSO) was prepared for use with headspace solid-phase microextraction (HS-SPME) combined with gas chromatography (GC) and electron capture detection (ECD), which was applied in order to determine nine chlorobenzenes in soil matrices. Due to the improved fiber preparation, which increases the percentage of calixarene in the coating, the new calixarene fiber exhibits very high extraction selectivity and sensitivity to chlorine-substituted compounds. Various parameters affecting the extraction efficiency were optimized in order to maximize the sensitivity during the chlorobenzene analysis. Interferences from different soil matrices with different characteristics were investigated, and the amount extracted was strongly influenced by the matrix. Therefore, a standard addition protocol was performed on the real soil samples. The linear ranges of detection for the chlorobenzenes tested covered three orders of magnitude, and correlation coefficients > 0.9976 and relative standard deviations (RSD) < 8% were observed. The detection limits were found at sub-ng/g of soil levels, which were about an order of magnitude lower than those given by the commercial poly(dimethylsiloxane) (PDMS) coating for most of the compounds. The recoveries ranged from 64 to 109.6% for each analyte in the real kaleyard soil matrix when different concentration levels were determined over the linear range, which confirmed the reliability and feasibility of the HS-SPME/GC-ECD approach using the fiber coated with diglycidyloxy-C[4]/OH-TSO for the ultratrace analysis of chlorobenzenes in complex matrices.
Resumo:
We used polyurethane foam units (PFUs) to collect persistent organic pollutants (POPs) from four sites in Baiyangdian Lake in July 2003. Following extraction from the PFUs, relative concentrations of seven organochlorine pesticides (OCPs) and ten polychlorinated biphenyls (PCBs) were determined by gas chromatography. OCPs and PCBs were detected in the microbial communities from all the four sampling stations. In terms of the total concentration of POPs (OCPs+ PCBs), two river estuary stations had more POP (18.45 mu g/L and 9.77 mu g/L) than the two mid-lake stations (4.75 mu g/L and 5.21 mu g/L), indicating that Baiyangdian Lake was significantly impacted by inflow from the Fu River and Baigou River.
Resumo:
Ultrasonic solvent extraction combined with solid-phase microextraction (SPME) with calix[4]arene/hydroxy-terminated silicone (C[4]/OHTSO) oil coated fiber was used to extract phthalate acid esters (PAEs) plasticizers in plastic, such as blood bags, transfusion tubing, food packaging bag, and mineral water bottle for analysis by gas chromatography (GC). Both extraction parameters (i.e. extraction time, extraction temperature, ionic strength) and conditions of the thermal desorption in a GC injector were optimized by analysis of eight phthalates. The fiber shows wonderful sensitivity and selectivity to the tested compounds. Owing to its high thermal stability (380 degreesC), the carryover effect that often encountered when using conventional fibers can be reduced by appropriately enhancing the injector temperature. The method showed linear response over two to four orders of magnitude with correlation coefficients (r) better than 0.996, and limits of detection (LOD) ranged between 0.006 and 0.084 mug l(-1). The relative standard deviation values obtained were less than or equal to 10%. bis-2-Ethylhexyl phthalate (DEHP) was the sole analyte detected in these plastics and recoveries were in the ranges 95.5-101.4% in all the samples. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Aryl hydrocarbon (Ah) receptor (Ah-agonist) effects of environmental samples containing polychlorinated aromatic hydrocarbons were evaluated using a 7-ethoxyresorufin-O-deethylase (FROD) assay of a primary hepatocyte culture from grass carp (Ctenopharyngodon idellus). The results were compared with those obtained from the assay using the rat hepatoma cell line H4IIE and chemical analysis using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). A dose-response relationship was observed between the EROD activities, either from primary hepatocyte culture assay or from H4IIE assay, and concentrations of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). The results showed that the assay based on the H4IIE cell line (EC50 = 0.83 mug/mL) is more sensitive to TCDD than the assay based on primary hepatocyte Culture (EC50 = 9.7 pg/mL). In tests of environmental samples, the results from the assay using primary hepatocyte culture were comparable to those from the assay using the H4IIE cell line and chemical analysis of concentrations of mixtures of polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/PCDF). The lack of a change in the activities of glutathione-S-transferase (GST) and lactate dehydrogenase (LDH) in cell culture upon exposure to TCDD indirectly indicates that the compound is persistent to biodegradation in the cell culture system. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
The retention equations ln k' = A + B/T of 49 polychlorinated dibenzo-p-dioxins (PCDDs) and 4 polybrominated dibenzo-p-dioxins (PBDDs) in gas chromatography (GC) have been investigated to evaluate the properties of regression coefficients A and B. The quantitative relationships between A and B values of PCDDs and those of PBDDs are found. The regression equations derived have correlation coefficients greater than 0.997. The A, B values of any PBDD can be predicted by using the A, B values of the PCDD according to these relationships. Using these predicted A and B values, the retention times of all PBDDs can be predicted at any temperature program. It is very useful to identify the peak position of any PBDD because at present there are only a few standards of PBDDs available. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
A new approach to study the quantitative relationships between chromatographic retentions and molecular structures of polychlorinated dibenzo-p-dioxins (PCDDs) is described. The retention equations of PCDDs log k' = A + B/T in gas chromatography (GC) are used to evaluate the properties of the regression coefficients A and B, which have been widely accepted as highly reliable chromatographic retentions. The quantitative relationships between the A, B values and the molecular structures are found. The molecular descriptors given for the first time in this article are very effective. As a result, the regression equations are derived with correlation coefficients greater than 0.9995. The A, B values of PCDDs with no standards available have been predicted according to these relationships. They are very useful in chromatographic identification. The retention times of all PCDDs can be conveniently predicted at any temperature program. Compared with the data obtained from the relevant experiments, the results of prediction are very accurate. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
A method has been developed for peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) at different temperature programs. Their retention behaviours are predicted on the basis of an identification database of retention values (A, B) of gas chromatography. By the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retentions of all PCDDs and PCDFs can be calculated. After comparison with the retentions of practical environmental samples, the predicted values have been proved to be very accurate. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
A novel sol-gel method is applied for the preparation of solid-phase microextraction (SPME) fibers. Scanning electron microscopy experiments suggested a porous structure for the poly(dimethylsiloxane) (PDMS) coating. SPME-GC analysis provided evidence that the sol-gel fibers have some advantages, such as high thermal stability, efficient extraction rates, high velocities of mass transfer, and spacious range of application.
Cleanup and quantification of polychlorinated dibenzo-p-dioxins/furans and polychlorinated biphenyls
Resumo:
By using modern techniques of isotope dilution, high-resolution gas chromatography/high-resolution mass spectrometry and multiple ions detection, an effective cleanup, qualitative and quantitative method was developed for polychlorinated dibenzo-p-dioxins/furans (PCDD/F) and polychlorinated biphenyls analysis. Based on the chromatographic relative retentions of PCDD/F, a software was established for automatic peak recognition of all the isomers from tetra- to octachlorine PCDD/F. It ensured good reliability and accuracy of the analytical data.
Resumo:
A software has been developed for the peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) after high resolution gas chromatography coupled with mass spectrometry (HRGC/HRMS). Based on the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retention times of all PCDD and PCDF can be calibrated automatically and accurately. Therefore, it is very convenient to identify the peaks by comparing the retention of samples and the calibrated retention times of their chromatograms. Hence, this approach is very significant because it is impossible to obtain always a standard chromatogram and PCDD/F analysis are very expensive and time consuming. The calibration results can be transferred to Excel for calculation. The approach is a first step to store costly and environmentally relevant data for future application.
Resumo:
Solid acid 40SiO(2)/TiO2-SO42- and solid base 30K(2)CO(3)/Al2O3-NaOH were prepared and compared with catalytic esterification activity according to the model reaction. Upgrading bio-oil by solid acid and solid base catalysts in the conditioned experiment was investigated, in which dynamic viscosities of bio-oil was lowered markedly, although 8 months of aging did not show much viscosity to improve its fluidity and enhance its stability positively. Even the dehydration by 3A molecular sieve still kept the fluidity well. The density of upgraded bio-oil was reduced from 1.24 to 0.96 kg/m(3), and the gross calorific value increased by 50.7 and 51.8%, respectively. The acidity of upgraded bio-oil was alleviated by the solid base catalyst but intensified by the solid acid catalyst for its strong acidification. The results of gas chromatography-mass spectrometry analysis showed that the ester reaction in the bio-oil was promoted by both solid acid and solid base catalysts and that the solid acid catalyst converted volatile and nonvolatile organic acids into esters and raised their amount by 20-fold. Besides the catalytic esterification, the solid acid catalyst carried out the carbonyl addition of alcohol to acetals. Some components of bio-oil undertook the isomerization over the solid base catalyst.
Resumo:
评价原状土通气培养法在反映黄土高原土壤供氮能力方面的效果。【方法】以采自于黄土高原差异较大的11个农田耕层土壤为供试土样,以包括和不包括土壤起始NO3--N原状土盆栽黑麦草累积吸氮量为参比,进行室内原状土通气培养法测定土壤供氮能力的研究。【结果】以包括土壤起始NO3--N盆栽试验植物吸氮量为参比,通气培养前CaCl2所淋洗起始NO3--N和起始矿质氮与5期黑麦草地上部氮素累积量密切相关,相关系数分别为0.856和0.862,达1%显著水平;与此相反,通气培养30周所矿化氮素、土壤起始矿质氮+通气培养30周矿化氮素、氮素矿化势(N0)及N0+起始矿质氮与5期黑麦草地上部氮素累积量间无显著相关关系,相关系数分别仅为0.410、0.553、0.492和0.419。以不包括土壤起始NO3--N盆栽试验植物吸氮量为参比,通气培养前CaCl2淋洗起始NO3--N和起始矿质氮与五期黑麦草地上部氮素累积量间的相关性尽管有所降低,但相关性仍达5%显著水平,相关系数分别为0.613和0.607;而通气培养30周矿化氮素、土壤起始矿质氮+通气培养30周矿化氮素、N0及N0+起始矿质氮与五期黑麦草地上部吸氮量的相关系数却明显...
Resumo:
采用间隙淋洗长期通气培养法,通过对黄土高原物理化学性质差异较大的10种农田土样起始矿质氮、起始提取态总氮、起始可溶性有机氮,以及培养期间淋洗矿质氮、淋洗总氮、可溶性有机氮含量及其与作物吸氮量关系的研究,分析并评价黄土高原主要农田土壤氮素矿化能力以及包括和不包括培养淋洗可溶性有机氮对土壤供氮能力的影响。结果表明,供试土样起始可溶性有机氮平均为N 23.9 mg/kg,是起始提取态总氮的28.8%,土壤全氮的2.4%。在通气培养淋洗总氮中,可溶性有机氮所占比例不高,经过217 d通气培养,淋洗出的可溶性有机氮平均为N 28.8mg/kg,占淋洗总氮量的19.8%。相关分析表明,淋洗可溶性有机氮量与第l季作物吸氮量相关不显著,但与连续2季作物总吸氮量显著相关。淋洗矿质氮、淋洗总氮与两季作物总吸氮量的相关系数明显高于与第一季作物吸氮量的相关系数;与第一季作物吸氮量达显著相关水平,与连续两季作物吸氮量达极显著相关水平。总体上看,可溶性有机氮和土壤全氮、土壤微生物氮不能作为反映短期可矿化氮的指标;间隙淋洗通气培养淋洗液中淋洗矿质氮、淋洗总氮是评价可矿化氮的较好指标,不仅适宜于第一季作物,而且也适用于对连续两季作物土壤供氮...