580 resultados para Photoluminescence peak
Resumo:
Infrared emission at 1.54 mu m excited optically and electrically from an erbium organic compound tris(acetylacetonato)(1,10-phenanthroline) erbium [Er(acac)(3)(phen)] is observed. The rare-earth complex is dispersed into a polymer matrix of poly(N-vinylcarbazole) (PVK) to fabricate an electroluminescent (EL) device with an ITO/PVK:Er(acac)(3)(phen)/Al:Li/Ag structure, where ITO represents indium-tin-oxide-coated glass. The device shows infrared EL emission at 1.54 mu m, which suggests a simple and cheap method to obtain a light source for 1.54-mu m-wavelength devices in optical communications. (C) 2000 American Institute of Physics. [S0021-8979(00)00301-7].
Resumo:
When the aggregation of C-60 is arranged in mono-dispersed state on the ITO substrate, the photoluminescence (PL) spectra are observed clearly. These emission peaks are attributed to recombination of self - trapped excitons, the zero-phonon exciton (R-0) and its phonon replicas.
Resumo:
When CaS:Sm3+, Eu2+ is excited at 476.5 nm (Ar+), the emission spectra taken at room temperature and at 77 K are different, indicating that there are two competitive energy transfer processes-Sm3+ --> Eu2+ and Eu2+ --> Sm3+ with phonon participation. So, the luminescence intensity of Sm3+ increases first, and then decreases as the concentration of Eu2+ is increasing. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
In this paper, we report the optical properties of SnO2 semiconductor nanoparticles in hydrosols and those of SnO2 semiconductor nanoparticles in organosols in which the surfaces of the particles are coated by a layer of organic surfactant molecules. The photoluminescence spectra of SnO2 semiconductor nanoparticles in the hydrosols and organosols in different conditions were measured and discussed. We conclude that the surface structure of the SnO2 semiconductor nanoparticles affects their optical properties strongly. The oxygen deficiencies on the surface of SnO2 semiconductor nanoparticles play an important role in the optical properties. The surface modification of the particles effectively removes the surface defects of the particles and enhances the intensity of luminescence.
Resumo:
Target transformation factor analysis was used to correct spectral interference in inductively coupled plasma atomic emission spectrometry (ICP-BES) for the determination of rare earth impurities in high purity thulium oxide. Data matrix was constructed with pure and mixture vectors and background vector. A method based on an error evaluation function was proposed to optimize the peak position, so the influence of the peak position shift in spectral scans on the determination was eliminated or reduced. Satisfactory results were obtained using factor analysis and the proposed peak position optimization method.
Resumo:
The multilayer Langmuir-Blodgett (LB) films of pr,ly 3-(2-(5-chlorobenzotriazole)ethyl) thiophene (PCBET) blended with amphibious arachidic acid (AA) were prepared and characterized. The photoluminescence intensity of the blend film was enhanced as the AA increased by a certain amount. The PCBET excimers were not formed in the blend LB films.
Resumo:
A method has been developed for peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) at different temperature programs. Their retention behaviours are predicted on the basis of an identification database of retention values (A, B) of gas chromatography. By the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retentions of all PCDDs and PCDFs can be calculated. After comparison with the retentions of practical environmental samples, the predicted values have been proved to be very accurate. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Performance of comprehensive two-dimensional liquid chromatography system is greatly improved than we reported previously by using a silica monolithic column as for the second dimensional separation. Due to the increase of the elution speed on the second dimensional monolithic column, the first dimensional column efficiency and analysis rate can be greatly improved as comparing with conventionally second dimensional column. The developed system was applied to analysis of methanol extraction of two umbelliferae herbs Ligusticum chuanxiong Hort. and Angelica sinensis (Oliv.) Diels by using CN column as for the first dimensional separation and a silica monolithic ODS column for the second dimensional separation, and the obtained three-dimensional chromatograms were treated by normalization of peak heights with the value of the highest peak or setting a certain value using a software written in-house. It was observed that much more peaks for low-abundant components in TCM extract can clearly be detected here than we reported before, due to the large difference for the amount of components in TCMs' extract. With the above improvements in separation performance and data treatment, totally about 120 components in methanol extraction of Rhizoma chuanxiong and 100 in A. sinensis were separated with UV detection within 130 min. This result meant that both the number of peaks detected increase twice but the analysis time decease twice if comparing with the previously reported result. (c) 2005 Published by Elsevier B.V.