98 resultados para simple defecation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple ac resistance bridge is proposed. The stability of the design is better than 10(-6), which is especially suitable for detecting tiny changes of resistance. An example of magnetoresistance measurement for a 220 nm Au film shows the good performance of the bridge. (C) 2009 American Institute of Physics. [DOI: 10.1063/1.3202284]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method based on the effective index method was used to estimate the minimum bend radii of curved SOI waveguides. An analytical formula was obtained to estimate the minimum radius of curvature at which the mode becomes cut off due to the side radiative loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate that the carrier capture and relaxation processes in InAs/GaAs quantum dots can be detected by a simple degenerate pump-probe technique. We have observed a rising process in the transient reflectivity, following the initial fast relaxation in a GaAs matrix, and assigned this rising process to the carrier capture from the GaAs barriers to the InAs layers. The assignment was modeled using the Kramers-Kronig relations. The capture time was found to depend strongly on the InAs layer thickness as well as on the excitation density and photon energy. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simple reflection technique is usually used to measure the linear electro-optic (EO) coefficient (Pockels coefficient) in the development of EO polymer thin films. But there are some problems in some articles in the determination of the phase shift between the s and p light modes of a laser beam waveguided into the polymer film while a modulating voltage is applied across the electrodes, and different expressions for the linear EO coefficient measured have been given in these articles. In our research, more accurate expression of the linear EO coefficient was deduced by suitable considering the phase shift between the s and p light modes. The linear EO coefficients of several polymer thin films were measured by reflection technique, and the results of the Linear EO coefficient calculated by different expressions were compared. The limit of the simple reflection technique for measuring the linear EO coefficient of the polymer thin films was discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ground state of a double quantum-dot structure is studied by a simplified Anderson-type model. Numerical calculations reveal that the ground-state level of this artificial molecule increases with the increasing single particle level of the dot, and also increases with the decreasing transfer integrals. We show the staircase feature of the electron occupation and the properties of the ground-state eigenvector by varying the;single particle level of the dot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Submitted by 阎军 (yanj@red.semi.ac.cn) on 2010-06-04T07:06:36Z No. of bitstreams: 1 A simple method to realize large-bandwidth and high-efficiency wavelength conversion in Si waveguide.pdf: 277035 bytes, checksum: ca7e272b2286b305d385825417857f21 (MD5)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emporiki Bank; Microsoft; Alpha Bank