113 resultados para harmonic oscillators


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Frequency resolved optical gating (FROG), is an effective technique for characterizing the ultrafast laser pulses. The multi-shot second harmonic generation (SHG) FROG is the most sensitive one in different FROGs. In this paper we use this technique to measure the femtosecond optical pulses generated by a conventional Ti:sapphire oscillator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Second-harmonic generation was observed in Ge(20)AS(25)S(55) chalcogenide glass irradiated by an electron beam. The second-harmonic intensity increased with increasing electron-beam current and accelerating voltage. The second-harmonic generation in Ge20As25S55 glass was caused by the space-charge electrostatic field that was generated by irradiation of an electron beam. Second-order nonlinearity chi ((2)) as great as 0.8 pm/V was obtained. The results of measurements of thermally stimulated depolarization current indicated that the glass was poled in the thin layers of its surface (several micrometers) and that the nonlinearity was stable. (C) 2001 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on photoinduced second-harmonic generation (SHG) in chalcogenide glasses. Fundamental and second-harmonic waves from a nanosecond pulsed Nd:YAG laser were used to induce second-order nonlinearity in chalcogenide glasses. The magnitude of SHG in 20Ge . 20As . 60S glass was 10(4) larger than that of tellurite glass with a composition of 15Nb(2)O(5) . 85TeO(2) (mol.%). Moreover, no apparent decay of photoinduced SHG in 20Ge . 20As . 60S glass was observed after optical poling at room temperature. We suggest that the large and stable value of X-(2) is due to the induced defect structures and large X-(3) of the chalcogenide glasses. (C) 2001 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We develop a swept frequency method for measuring the frequency response of photodetectors; (PDs) based on harmonic analysis. In this technique, a lightwave from a laser source is modulated by a radio-frequency (RF) signal via a Mach-Zehnder LiNbO3 modulator, and detected by a PD under test. The measured second-order harmonic of the RF signal contains information of the frequency responses and nonlinearities of the RF source, modulator, and PD. The frequency response of the PD alone is obtained by deducting the known frequency responses and nonlinearities of the RF source and modulator. Compared with the conventional swept frequency method, the measurement frequency range can be doubled using the proposed method. Experiment results show a good agreement between the measured results and those obtained using other techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the solid-state double-dot interferometer, the phase shifted interference pattern induced by the interplay of inter-dot Coulomb correlation and multiple reflections is analyzed by harmonic decomposition. Unexpected result is uncovered, and is discussed in connection with the which-path detection and electron loss. (C) 2009 Elsevier B.V. All rights reserved.