41 resultados para automatic virtual camera


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semisupervised dimensionality reduction has been attracting much attention as it not only utilizes both labeled and unlabeled data simultaneously, but also works well in the situation of out-of-sample. This paper proposes an effective approach of semisupervised dimensionality reduction through label propagation and label regression. Different from previous efforts, the new approach propagates the label information from labeled to unlabeled data with a well-designed mechanism of random walks, in which outliers are effectively detected and the obtained virtual labels of unlabeled data can be well encoded in a weighted regression model. These virtual labels are thereafter regressed with a linear model to calculate the projection matrix for dimensionality reduction. By this means, when the manifold or the clustering assumption of data is satisfied, the labels of labeled data can be correctly propagated to the unlabeled data; and thus, the proposed approach utilizes the labeled and the unlabeled data more effectively than previous work. Experimental results are carried out upon several databases, and the advantage of the new approach is well demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new image segmentation method that applies an edge-based level set method in a relay fashion. The proposed method segments an image in a series of nested subregions that are automatically created by shrinking the stabilized curves in their previous subregions. The final result is obtained by combining all boundaries detected in these subregions. The proposed method has the following three advantages: 1) It can be automatically executed without human-computer interactions; 2) it applies the edge-based level set method with relay fashion to detect all boundaries; and 3) it automatically obtains a full segmentation without specifying the number of relays in advance. The comparison experiments illustrate that the proposed method performs better than the representative level set methods, and it can obtain similar or better results compared with other popular segmentation algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A facile, mild and rapid solid phase synthetic route free of column chromatographic purification to the synthesis of soluble monodisperse long-chain oligo(1,4-phenyleneethynylene)s is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

介绍了一种利用人机合作技术在非结构环境引导机械手抓取静态目标的方法.分别介绍了将激光—CCD摄像机系统与操作者的经验相结合获得抓取目标位置的方法,及将虚拟现实技术与操作者的经验相结合获得抓取目标姿态的方法.继而利用基于模型的视觉引导技术,引导手臂完成抓取操作.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

以7 000 m载人潜水器的工程需求为背景,以水下单目摄像机为视觉传感器,进行了水下机器人动力定位方法研究。该动力定位方法利用视觉系统测量得到水下机器人与被观察目标之间的三维位姿关系,通过路径规划、位置控制和姿态控制分解,逐步使机器人由初始位姿逼近期望位姿并最终定位于期望位姿,从而实现了机器人的4自由度动力定位。通过水池实验验证了提出的动力定位方法,并且机器人能够抵抗恒定水流干扰和人工位置扰动。同时,该动力定位方法还可以实现机器人对被观察目标的自动跟踪。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

本文提出的系统主要为了在自动化传输带上进行零件的自动识别、定位、定向。曾用该系统对三十多种钟表零件进行反复验证,效果甚佳。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

相机标定是2D图像重建3D测度信息的关键步骤,也是一项耗时的任务,由于标定过程中经常需要人工寻找对应点。本文提出了一种基于圆形标志点的全自动相机标定方法。首先,在传统圆形标志点模板的基础上增设了5个方位圆。然后提出了新标定板下图像特征点的自动检测和匹配算法。匹配结果直接作为Zhang的算法的输入,从而计算出相机内外参数,避免了标定过程的人工干预。最终实验结果显示了所提方法在不同场景和光照条件下的自动性和正确性。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.