162 resultados para alternating tapping


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comb-like polymers (CP) based on modified alternating methyl vinyl ether/maleic anhydride copolymer with oligo-oxyethylene side chains of the type -O(CH2CH2O)(n)CH3 have been synthesized and characterized, and complexed with lithium salts to form amorphous polymer electrolytes. CP/salt complexes showed conductivity up to 10(-5)Scm(-1) at room temperature. The temperature dependence of ionic conductivity suggests that the ion transport is controlled by segmental motion of the polymer, shown by linear curves obtained in Vogel-Tammann-Fulcher plots. The ionic conductivity maximum moves to a higher salt concentration as the temperature increases. IR results indicate that the ester in CP might decompose at 140 degrees C and reproduce the maleic anhydride ring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared spectra of alternating LB films of octadecyl-TCNQ/CuPc are studied. Charge-transfer complexes are formed in LB films and conductance increases about three orders than that of pure CuPc LB films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comb-like polymers (CP) based on modified alternating methyl vinyl ether/maleic anhydride copolymer with oligo-oxyethylene side chains of the type-O(CH2CH2O)(n)CH3 have been synthesized and characterized, and complexed with LiNO3 to form an amorphous polymer electrolyte. CP/salt complexes showed conductivity up to 10(-5) S/cm at room temperature. The temperature dependence of ionic conductivity suggests that the ion transport is controlled by segmental motion of the polymer, shown by linear curves obtained in Vogel-Tammann-Fulcher plots. The ionic conductivity maximum moves to a higher salt concentration as the temperature increases. IR results also indicate that the ester in CP might decompose at 140 degrees C and reproduce the maleic anhydride ring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comb polymer with oligo-oxyethylene side chains of the type -(CH2CB2O)(12)CH3 was prepared from methyl vinyl ether/maleic anhydride copolymer and poly (ethylene glycol) methyl ether. The polymer can dissolve LiClO4 salt to form homogeneous amorphous polymer electrolyte. The ac ion conduction was measured using the complex impedance method, and conductivities were investigated as functions of temperatures and salt concentration. The complexes were first found to have two classes of glass transition which increase with increasing salt content, The optimum conductivity attained at 25 degrees C is in the order of 5.50 x 10(-6)Scm(-1). IR spectroscopy was used to study the cation-polymer interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

自从1986年G. Binnig 等发明原子力显微镜(AFM)以来,纳米科技研究得到了快速发展,纳米科技研究的最终目标是从纳米甚至分子与原子尺度上制造功能器件或系统,而实现此目标的手段之一是研制能够在纳米尺度上进行精确可控操作的装置、方法与技术。对此,学者们对基于 AFM 的纳米操作进行了大量研究。基于AFM-Tapping模式的纳米观测与操作具有成本低、易实现性等特点,因而近年来成为纳米技术研究的热点。但基于AFM探针的纳米观测和操作的基本理论仍然很不完善,许多情况下缺乏基于探针观测与操作的纳观作用力的合理解释与描述,因此限制了基于探针的纳米技术发展。为了解决这一问题,本论文在国家自然科学基金项目“基于机器人化的纳米操作方法研究(60575060)”的支持下,广泛收集和查阅国内外相关资料,重点开展了AFM-Tapping模式下探针动力学解释方法与建模研究,并进行了基于AFM-Tapping的纳米操作方法研究。主要研究工作如下: 1)针对探针动力学建模问题,开展了基于Hamilton原理和变分原理的有边界条件的探针一维悬臂梁建模方法研究。利用模态叠加法和模态函数正交性对探针各阶模态进行了解耦分析,得到了解耦的探针动力学方程。 2)开展了纳观尺度下探针-样品作用力研究。分析与阐述了毛细力、接触力和摩擦力等纳观尺度作用力;开展了基于Lennard-Jones势模型的不同形状探针与样品间的相互作用势描述方法研究;并根据势能-力之间的关系,研究了可描述半球形探针与样品间相互作用力的数学表达式。 3)开展了基于弹簧振子模型的纳观非线性力作用下探针振动问题分析研究。首次提出了基于探针弹性力与非线性纳观力平衡关系的探针振动状态区域划分方法。在探针振动能量平衡分析的基础上,研究了AFM-Tapping模式中的双稳态现象,进而得到了描述双稳态现象的解析表达式。最后采用Lyapunov指数分析的方法,证明了探针在非线性振动中确实存在着混沌现象。 4)研究了基于AFM-Tapping模式的纳米操作方法。通过研究探针振幅调节控制和预编程作业轨迹规划策略,提出了一种具有增强探针概念的纳米作业方法。该方法可以在参数设定和预编程条件下自动完成纳米尺度的平移和旋转操作,从而可以大大提高纳米操作的效率和精度。实验结果验证了该方法的有效性。本文的工作为纳米操作方法的研究提供了可以借鉴的理论与实验经验,有助于推动基于AFM的纳米操作与制造技术的发展。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To accomplish laser-induced thermal loading simulation tests for pistons,the Gaussian beam was modulated into multi-circular beam with specific intensity distribution.A reverse method was proposed to design the intensity distribution for the laser-induced thermal loading based on finite element(FE) analysis.Firstly,the FE model is improved by alternating parameters of boundary conditions and thermal-physical properties of piston material in a reasonable range,therefore it can simulate the experimental resul...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Arc voltage fluctuations in a direct current (DC) non-transferred arc plasma generator are experimentally studied, in generating a jet in the laminar, transitional and turbulent regimes. The study is with a view toward elucidating the mechanism of the fluctuations and their relationship with the generating parameters, arc root movement and flow regimes. Results indicate that the existence of a 300 Hz alternating current (AC) component in the power supply ripples does not cause the transition of the laminar plasma jet into a turbulent state. There exists a high frequency fluctuation at 4 kHz in the turbulent jet regime. It may be related to the rapid movement of the anode attachment point of the arc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By using Lagrangian method, the flow properties of a dusty-gas point source in a supersonic free stream were studied and the particle parameters in the near-symmetry-axis region were obtained. It is demonstrated that fairly inertial particles travel along oscillating and intersecting trajectories between the bow and termination shock waves. In this region,formation of "multi-layer structure" in particle distribution with alternating low- and highdensity layers is revealed. Moreover, sharp accumulation of particles occurs near the envelopes of particle trajectories.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Ga1-xMnxSb samples were fabricated by the implantation of Mn ions into GaSb (1 0 0) substrate with mass-analyzed low-energy dual ion beam deposition system, and post-annealing. Auger electron spectroscopy depth profile of the Ga1-xMnxSb samples showed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The vibration analysis of an adhered S-shaped microbeam under alternating sinusoidal voltage is presented. The shaking force is the electrical force due to the sinusoidal voltage. During vibration, both the microbeam deflection and the adhesion length keep changing. The microbeam deflection and adhesion length are numerically determined by the iteration method. As the adhesion length keeps changing, the domain of the equation of motion for the microbeam (unadhered part) changes correspondingly, which results in changes of the structure natural frequencies. For this reason, the system can never reach a steady state. The transient behaviors of the microbeam under different shaking frequencies are compared. We deliberately choose the initial conditions to compare our dynamic results with the existing static theory. The paper also analyzes the changing behavior of adhesion length during vibration and an asymmetric pattern of adhesion length change is revealed, which may be used to guide the dynamic de-adhering process. The abnormal behavior of the adhered microbeam vibrating at almost the same frequency under two quite different shaking frequencies is also shown. The Galerkin method is used to discretize the equation of motion and its convergence study is also presented. The model is only applicable in the case that the peel number is equal to 1. Some other model limitations are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mn+ irons were implanted to n-type Ge(1 1 1) single crystal at room temperature with an energy of 100 keV and a dose of 3 x 10(16) cm(-2). Subsequently annealing was performed at 400degreesC for 1 h under flowing nitrogen gas. X-ray diffraction measurements show that as-implanted sample is amorphous and the structure of crystal is restored after annealing. Polycrystalline germanium is formed in annealed sample. There are no new phases found except germanium. The samples surface morphologies indicate that annealed sample has island-like feature while there is no such kind of characteristic in as-implanted sample. The elemental composition of annealed sample was analyzed by Auger electron spectroscopy. It shows that manganese ions are deeply implanted into germanium substrate and the highest manganese atomic concentration is 8% at the depth of 120 nm. The magnetic properties of samples were investigated by an alternating gradient magnetometer. The annealed sample shows ferromagnetic behavior at room temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mn ions were implanted to n-type Si(0 0 1) single crystal by low-energy ion beam deposition technique with an energy of 1000 eV and a dose of 7.5 x 10^{17} cm^{-2}. The samples were held at room temperature and at 300degreesC during implantation. Auger electron spectroscopy depth profiles of samples indicate that the Mn ions reach deeper in the sample implanted at 300degreesC than in the sample implanted at room temperature. X-ray diffraction measurements show that the structure of the sample implanted at room temperature is amorphous while that of the sample implanted at 300degreesC is crystallized. There are no new phases found except silicon both in the two samples. Atomic force microscopy images of samples indicate that the sample implanted at 300degreesC has island-like humps that cover the sample surface while there is no such kind of characteristic in the sample implanted at room temperature. The magnetic properties of samples were investigated by alternating gradient magnetometer (AGM). The sample implanted at 300degreesC shows ferromagnetic behavior at room temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mn+ ions were implanted into n-type Ge(111) single crystal at room temperature at an energy of 100 keV with a dose of 3 x 1016 cm-2. Subsequent annealing was performed on the samples at 400 °C and 600 °C in a flowing nitrogen atmosphere. The magnetic properties of the samples have been investigated by alternating gradient magnetometer at room temperature. The compositional properties of the annealed samples were studied by Auger electron spectroscopy and the structural properties were analyzed by X-ray diffraction measurements. Magnetization measurements reveal room-temperature ferromagnetism for the annealed samples. The magnetic analysis supported by compositional and structural properties indicates that forming the diluted magnetic semiconductor (DMS) MnxGe1-x after annealing may account for the ferromagnetic behavior in the annealed samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When the atomic force microscopy (AFM) in tapping mode is in intermittent contact with a soft substrate, the contact time can be a significant portion of a cycle, resulting in invalidity of the impact oscillator model, where the contact time is assumed to be infinitely small. Furthermore, we demonstrate that the AFM intermittent contact with soft substrate can induce the motion of higher modes in the AFM dynamic response. Traditional ways of modeling AFM (one degree of freedom (DOF) system or single mode analysis) are shown to have serious mistakes when applied to this kind of problem. A more reasonable displacement criterion on contact is proposed, where the contact time is a function of the mechanical properties of AFM and substrate, driving frequencies/amplitude, initial conditions, etc. Multi-modal analysis is presented and mode coupling is also shown. (c) 2006 Published by Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experiments concerning slightly slanting impact between a flat-ended rigid body and a flat-ended elastic cantilever column with a rectangular cross-section have been performed. The experimental results are compared with the theoretical ones. The small angle of incidence was measured by using an optical method. The impact process was studied by using a split disc for the rigid body, with the two halves bonded together and electrically insulated from each other. The disc and the column were parts of an electric circuit. Different contact states could be distinguished according to different voltage levels. Reasonably good agreement between theory and experiment was found. Thus, the impact duration has its minimum under perfectly axial impact as predicted by the theory. Also, the predicted process of alternating line and surface contact was observed. Furthermore, the existence of a small critical angle of incidence was verified. This critical angle of incidence divides the impact processes into two categories: (1) The rigid body and the column end come into surface contact before separation. (2) They separate without surface contact. Comparison of axial strains between theory and experiment shows good agreement.