141 resultados para Liquid-chromatographic Determination


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A comprehensive two-dimensional liquid chromatographic separation system based on the combination of a CN column and an ODS column is developed for the separation of components in a traditional Chinese medicine (TCM) Rhizoma chuanxiong. Two columns are coupled by a two-position, eight-port valve equipped with two storage loops and controlled by a computer. The effluent is detected by both the diode array detector and atmospheric pressure chemical ionization (APCI) mass spectrometer. More than 52 components in the methanol extract of R. chuanxiong were resolved and 11 of them were preliminary identified according to their UV and mass spectra. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The dynamic flow profiles and column efficiencies in conically shaped semi-preparative liquid chromatographic columns (inlet ID larger than outlet ID) with two different conical angles (7degrees and 15degrees) were studied. The dynamic flow profiles were studied by an on-column visualization method. Conical columns were compared with cylindrical column of the same length and internal volume. The results showed that the flow profile of a sample band in the conical column of 7degrees (50 mm x 17 mm --> 11 mm ID) was parabolic in shape. The sample band migrated slower in the wall region than in the central region, as in the cylindrical column (50 mm x 14 mm ID). However, the sample band in the conical column of 15degrees (50 mm x 20 mm --> 7 mm ID) migrated slower in the central region than in the wall region, resulting in a reverse parabolic flow profile, in contrast to that in cylindrical column. This indicated that a flat flow profile might be realized in a conical column with a conical angle between 7degrees and 15degrees. The conical column of 15degrees had the highest column efficiency among the three columns under the same conditions. Compared with the cylindrical column packed with identical packing material, the conical column of 15degrees had 22%-45% higher column efficiency and 11%-27% higher peak height.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A procedure is described for the preparation of a tubular electrode by chemical deposition of platinum at the end of a fused-silica capillary. The properties of the electrode were tested under liquid chromatographic conditions, demonstrating that both the static and the dynamic behaviour of the detection system satisfy the requirements of capillary chromatographic separations and compare well with a wall-jet amperometric system and with UV photometric detection. The detection system described is easy to prepare and does not require any time-consuming positioning of the electrode system as it is integrated into the separation part of the apparatus. (C) 1998 Elsevier Science B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A vitamin B-12 chemically modified electrode (CME) was constructed by adsorption of vitamin B-12 onto a glassy carbon surface. The electrode catalyzes the electrooxidation of hydrazine compounds over a wide pH range. The electrocatalytic behavior of hydrazines is elucidated with respect to the CME preparation conditions, solution pH, operating potential, mobile phase flow rate, and other variables. When applied to liquid chromatographic detection of the analytes, the vitamin B-12 CME yielded a linear response range over 2 orders of magnitude, and detection limits at the picomole level. The vitamin B-12 CME offers acceptable catalytic stability in both batch and flow systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An electrochemical detector which was constracted by using a carbon fibre electrode in a flow-through cell was connected with a liquid chromatographic column. Thus a sensitive,

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The soil organic partition coefficient (K-oc) is one of the most important parameters to depict the transfer and fate of a chemical in the soil-water system. Predicting K-oc by using a chromatographic technique has been developing into a convenient and low-cost method. In this paper, a soil leaching column chromatograpy (SLCC) method employing the soil column packed with reference soil GSE 17201 (obtained from Bayer Landwirtschaftszentrum, Monheim, Germany) and methanol-water eluents was developed to predict the K-oc of hydrophobic organic chemicals (HOCs), over a log K-oc range of 4.8 orders of magnitude, from their capacity factors. The capacity factor with water as an eluent (k(w)') could be obtained by linearly extrapolating capacity factors in methanol-water eluents (k') with various volume fractions of methanol (phi). The important effects of solute activity coefficients in water on k(w)' and K-oc were illustrated. Hence, the correlation between log K-oc and log k(w)' (and log k') exists in the soil. The correlation coefficient (r) of the log K-oc vs. log k(w)' correlation for 58 apolar and polar compounds could reach 0.987, while the correlation coefficients of the log K-oc-log k' correlations were no less than 0.968, with phi ranging from 0 to 0.50. The smaller the phi, the higher the r. Therefore, it is recommended that the eluent of smaller phi, such as water, be used for accurately estimating K-oc. Correspondingly, the r value of the log K-oc-log k(w)' correlation on a reversed-phase Hypersil ODS (Thermo Hypersil, Kleinostheim, Germany) column was less than 0.940 for the same solutes. The SLCC method could provide a more reliable route to predict K-oc indirectly from a correlation with k(w)' than the reversed-phase liquid chromatographic (RPLC) one.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

采用固相微萃取(SPME)高效液相色谱法(HPLC)同时测定了水中苯酚、4-硝基酚、3-甲基酚、2,4-二氯酚、2,4,6-三氯酚、五氯酚等六种酚类化合物的含量.采用ZORBOX SB-C18柱,以甲醇-1%乙酸水溶液为流动相进行梯度洗脱,流速为1.0 mL/min.紫外检测波长为254、280 nm.六种酚类化合物的检出限为0.31~1.90μg/L,加标回收率为88%~103%.该方法操作简单,能快速、准确地检测水中的酚类化合物.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Modified nucleosides derived predominantly from transfer ribonucleic acid (tRNA) have been studied as possible tumor markers. In this paper a reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been applied to study 15 normal and modified nucleosides in serum. The nucleoside levels in normal human serum were established, and the concentrations of 15 nucleosides in serum from 19 cancer patients were determined, it was found that the concentrations of modified nucleosides were significantly higher in patient sera. Based on 15 nucleoside concentrations in serum, factor analysis could classify correctly 90% of cancer patients from the normal humans Further work showed that urine was slightly better than serum when determining nucleosides as biological marker candidates. More work is ongoing to determine the clinical usefulness of modified nucleosides as tumor markers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Modified nucleosides, formed post-transcriptionally in RNA by a number of modification enzymes, are excreted in abnormal levels in the urine of patients with malignant tumors. To test their usefulness as tumor markers, and to compare them with the conventional tumor markers, a reversed-phase high-performance liquid chromatographic (RP-HPLC) method and a factor analysis method have been used to study the excretion pattern of nucleosides of breast cancer patients. A clear cut differentiation of the breast cancer group and the healthy individuals in two clusters without overlapping was obtained. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and 2-(9-acridone)-acetic acid (AAA), two novel precolumn fluorescent derivatization reagents, have been developed and compared for analysis of primary aromatic amines by high performance liquid chromatographic fluorescence detection coupled with online mass spectrometric identification. PPIA and AAA react rapidly and smoothly with the aromatic amines on the basis of a condensation reaction using 1-ethyl-3-(3dimethylaminopropyl)-carbodiimide (EDC) as dehydrating catalyst to form stable derivatives with emission wavelengths at 380 and 440 nm, respectively. Taking six primary aromatic amines (aniline, 2-methylaniline, 2-methoxyaniline, 4-methylaniline, 4-chloroaniline, and 4-bromoaniline) as testing compounds, derivatization conditions such as coupling reagent, basic catalyst, reaction temperature and time, reaction solvent, and fluorescent labeling reagent concentration have also been investigated. With the better PPIA method, chromatographic separation of derivatized aromatic amines exhibited a good baseline resolution on an RP column. At the same time, by online mass spectrometric identification with atmospheric pressure chemical ionization (APCI) source in positive ion mode, the PPIA-labeled derivatives were characterized by easy-to-interpret mass spectra due to the prominent protonated molecular ion m/z [M + H](+) and specific fragment ions (MS/MS) m/z 335 and 295. The linear range is 24.41 fmol-200.0 pmol with correlation coefficients in the range of 0.9996-0.9999, and detection limits of PPIA-labeled aromatic amines are 0.12-0.21 nmol/L (S/N = 3). Method repeatability, precision, and recovery were evaluated and the results were excellent for the efficient HPLC analysis. The most important argument, however, was the high sensitivity and ease-of-handling of the PPIA method. Preliminary experiments with wastewater samples collected from the waterspout of a paper mill and its nearby soil where pollution with aromatic amines may be expected show that the method is highly validated with little interference in the chromatogram.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Alcohols were derivatised to their carbazole-9-N-acetic acid (CRA) esters with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC . HCl) as the dehydrating agent. Studies on derivatisation conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives. The retention behaviour of alcohol derivatives was investigated by varying mobile phase compositions (ACN-water and MeOH-water). The parameters from the equation log k'=A-BX were evaluated by retention data of derivatives using an isocratic elution with different mobile phases. The results indicated that the parameters derived allowed computation of retention factors in good agreement with experiments. At the same time, a general equation was derived that makes possible predictions of partition coefficient in binary mobile phases with different proportions of organic solvent to water based on some simple regression analysis. The LC separation for the derivatised alcohols containing higher carbon alcohols showed good reproducibility on a reversed-phase C-18 column with gradient elution. The detection limits (excitation at 335 nm, emission at 360 nm) for derivatised alcohols (signal-to-noise ratio=3:1) were in the range of 0.1-0.4 pg per injection. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A sensitive and selective liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantitative determination of microcystin-LR (MC-LR) and its glutathione conjugate (MC-LR-GSH) in fish tissues. The analytes were extracted from fish liver and kidney using 0.01 M EDTA-Na-2-5% acetic acid, followed by a solid-phase extraction (SPE) on Oasis HLB and silica cartridges. High-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MC-LR and its glutathione conjugate in fish liver and kidney. Recoveries of analytes were assessed at three concentrations (0.2, 1.0, and 5 mu g g(-1) dry weight [DW]) and ranged from 91 to 103% for MC-LR, and from 65.0 to 75.7% for MC-LR-GSH. The assay was linear within the range from 0.02 to 5.0 mu g g(-1) DW, with a limit of quantification (LOQ) of 0.02 mu g g(-1) DW. The limit of detection (LOD) of the method was 0.007 mu g g(-1) DW in both fish liver and kidney. The overall precision was determined on three different days. The values for within- and between-day precision in liver and kidney were within 15%. This method was applied to the identification and quantification of MC-LR and its glutathione conjugate in liver and kidney of fish with acute exposure of MC-LR. (c) 2007 Elsevier B.V. All rights reserved.