96 resultados para Limit of detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method of loop-mediated isothermal amplification (LAMP) was employed to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). The amplification could be finished in 60 min under isothermal condition at 64 degrees C by employing a set of four primers targeting the cap gene of PCV2. The LAMP assay showed higher sensitivity than the conventional PCR, with a detection limit of five copies per tube of purified PCV2 genomic DNA. No cross-reactivity was observed from the samples of other related viruses including porcine circovirus type 1 (PCV1), porcine parvovirus (PPV), porcine pseudorabies virus (PRV) and porcine reproductive and respiratory syndrome virus (PRRSV). The detection rate of PCV2 LAMP for 86 clinical samples was 96.5% and appeared greater than that of the PCR method. The LAMP assay reported can provide a rapid yet simple test of PCV2 suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Highly sensitive amperometric detection of dihydronicotinamide adenine dinucleotide (NADH) by using novel synthesized carbon nanofibers (CNFs) without addition of any mediator has been proposed. The CNFs were prepared by combination of electrospinning technique with thermal treatment method and were applied without any oxidation pretreatment to construct the electrochemical sensor. In amperometric detection of NADH, a linear range up to 11.45 mu M with a low detection limit of 20 nM was obtained with the CNF-modified carbon paste electrode (CNF-CPE).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work,we report the application of novel, water-soluble fluorescent Ag clusters in fluorescent sensors for detecting cysteine, an important biological analyte. The fluorescence of poly(methacrylic acid) (PMAA)templated Ag clusters was found to be quenched effectively by cysteine, but not when the other alpha-amino acids were present. By virtue of the specific response, a new, simple, and sensitive fluorescent method for detecting cysteine has been developed based on Ag clusters. The present assay allows for the selective determination of cysteine in the range of 2.5 x 10(-8) to 6.0 x 10(-6) M with a detection limit of 20 nM at a signal-to-noise ratio of 3. Based on the absorption and fluorescence studies, we suggested that cysteine quenched the emission by the thiol-adsorption-accelerated oxidation of the emissive Ag clusters. The present study shows a promising step toward the application of silver clusters, a new class of attractive fluorescence probes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We developed a stable, sensitive electrochemiluminescence (ECL) biosensor based on the synthesis of a new sol-gel material with the ion-exchange capacity sol-gel to coimmobilize the Ru(bpy)(3)(2+) and enzyme. The partial sulfonated (3-mercaptopropyl)-trimethoxysilane sol-gel (PSSG) film acted as both an ion exchanger for the immobilization of Ru(bpy)(3)(2+) and a matrix to immobilize gold nanoparticles (AuNPs). The AuNPs/PSSG/Ru(bpy)(3)(2+) film modified electrode allowed sensitive the ECL detection of NADH as low as 1 nM. Such an ability of AuNPs/PSSG/Ru(bpy)(3)(2+) film to promote the electron transfer between Ru(bpy)(3)(2+) and the electrode suggested a new, promising biocompatible platform for the development of dehydrogenase-based ECL biosensors. With alcohol dehydrogenase (ADH) as a model, we then constructed an ethanol biosensor, which had a linear range of 5 mu M to 5.2 mM with a detection limit of 12 nM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a new fluorescent method for sensitive detection of biological thiols in human plasma was developed using a near-infrared (NIR) fluorescent dye, FR 730. The sensing approach was based on the strong affinity of thiols to gold and highly efficient fluorescent quenching ability of gold nanoparticles (Au NPs). In the presence of thiols, the NIR fluorescence would enhance dramatically due to desorption of FR 730 from the surfaces of Au NPs, which allowed the analysis of thiol-containing amino acids in a very simple approach. The size of Au NPs was found to affect the fluorescent assay and the best response for cysteine detection was achieved when using Au NPs with the diameter of 24 nm, where a linear range of 2.5 x 10(-8) M to 4.0 x 10(-6) M and a detection limit of as low as 10 nM was obtained. This method also demonstrated a high selectivity to thiol-containing amino acids due to the strong affinity of thiols to gold.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive fluorescent method for detecting cyanide has been developed based on the inner filter effect (IFE) of silver nanoparticles (Ag NPs). With a high extinction coefficient and tunable plasmon absorption feature, Ag NPs are expected to be a powerful absorber to tune the emission of the fluorophore in the IFE-based fluorescent assays. In the present work, we developed a turn-on fluorescent assay for cyanide based on the strong absorption of Ag NPs to both excitation and emission light of an isolated fluorescence indicator. In the presence of cyanide, the absorber Ag NPs will dissolve gradually, which then leads to recovery of the IFE-decreased emission of the fluorophore. The concentration of Ag NPs in the detection system was found to affect the fluorescence response toward cyanide greatly. Under the optimum conditions, the present IFE-based approach can detect cyanide ranging from 5.0 x 10 (7) to 6.0 x 10 (4) M with a detection limit of 2.5 x 10 (7) M, which is much lower than the corresponding absorbance-based approach and compares favorably with other reported fluorescent methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a simple, label-free and regenerative method was proposed to study the interaction between aptamer and small molecule by using methylene blue (MB+) as an electrochemical indicator. A thiolated capture probe containing twelve bases was firstly self-assembled on gold electrode by gold-sulfur affinity. Aptamer probe containing thirty two bases, which was designed to hybridize with capture DNA sequence and specifically recognize adenosine, was then immobilized on the electrode surface by hybridization reaction. MB+ was abundantly adsorbed on the aptamer probe by the specific interaction between MB+ and guanine base in aptamer probe. MB+-anchored aptamer probe can be forced to dissociate from the sensing interface after adenosine triggered structure switching of the aptamer. The peak current of MB+ linearly decreased with the concentration of adenosine over a range of 2 x 10 (8)- x 10 (6) M with a detection limit of 1 x 10 (8) M. In addition, we examined the selectivity of this electrochemical biosensor for cytidine, uridine and guanosine that belonged to the nucleosides family and possessed 1 similar structure with adenosine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the functional nucleic acids studied, adenine-rich nucleic acids have attracted attention due to their critical roles in many biological processes and self-assembly-based nanomaterials, especially deoxyribonucleic acids (abbreviated as poly(dA)). Therefore the ligands binding to poly(dA) might serve as potential therapeutic agents. Coralyne, a kind of planar alkaloid, has been firstly found that it could bind strongly to poly(dA). This work herein reports an approach for visual sensing of the coralyne-poly(dA) interaction. This method was based on the coralyne inducing poly(dA) into the homo-adenine DNA duplex and the difference in electrostatic affinity between single-stranded DNA and double-stranded DNA with gold nanoparticles (GNPs). Furthermore, we applied the recognition process of the interaction between coralyne and poly(dA) into specific coralyne detection with the assistance of certain software (such as Photoshop). A linear response from 0 to 728 nM was obtained for coralyne, and a detection limit of 91 nM was achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel [Ru(bpy)(2) (dcbpy)NHS] labeling/aptamer-based biosensor combined with gold nanoparticle amplification for the determination of lysozyme with an electrochemiluminescence (ECL) method is presented. In this work, an aptamer, an ECL probe, gold nanoparticle amplification, and competition assay are the main protocols employed in ECL detection. With all the protocols used, an original biosensor coupled with an aptamer and [Ru(bpy)(2)(dcbpy)NHS] has been prepared. Its high selectivity and sensitivity are the main advantages over other traditional [Ru(bpy)(3)](2+) biosensors. The electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM) characterization illustrate that this biosensor is fabricated successfully. Finally, the biosensor was applied to a displacement assay in different concentrations of lysozyme solution, and an ultrasensitive ECL signal was obtained. The ECL intensity decreased proportionally to the lysozyme concentration over the range 1.0 x 10-(13)-1.0 x 10(-8) mol L-1 with a detection limit of 1.0 x 10(-13) mol L-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report here a novel AMP biosensor based on the aptamer-induced disassembly of fluorescent and magnetic nano-silica sandwich complexes with a direct detection limit of 0.1 mu M.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method for prolidase (PLD, EC 3.4.13.9) activity assay was developed based on the determination of proline produced from enzymatic reaction through capillary electrophoresis (CE) with tris(2,2'-bipyridyl)ruthenium(11) [Ru(bpy)(3)(2+)] electrochemiluminescence detection (ECL). A detection limit of 12.2 fmol (S/N = 3) for proline, corresponding to 1.22 x 10(-8) units of prolidase catalyzing for 1 min was achieved. PLD activity determined by CE-ECL method was in agreement with that obtained from the classical Chinard's one. CE-ECL showed its powerful resolving ability and selectivity as no sample pretreatmentwas needed and no interference existed. The clinical utility of this method was successfully demonstrated by its application to assay PLD activity in the serum of diabetic patients in order to evaluate collagen degradation in diabetes mellitus (DM). The results indicated that enhanced collagen degradation occurred in DM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new sensitive assay for aspartate aminotransterase (AST) and alanine aminotransferase (ALT) activities in biofluids was developed, based on the separation and detection of alanine, glutamate, and aspartate using capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. The three amino acids were separated in 5 mM phosphate of pH 2.1 as background electrolyte, and detected on a 500 mu m platinum disk electrode at 1.2 V (versus Ag/AgCl) in the presence of 10 mM tris(2,2'-bipyridyl)ruthenium(II) dissolved in 80 mM phosphate of pH 10.5. A mass detection limit of 37.3 fmol (or 81.5 fmol) for glutamate, corresponding to the product in the enzyme reaction catalyzed by 1.24 x 10(-9) U AST (or 2.72 x 10(-9) U ALT) in a 30 min reaction period, was achieved. This assay was applied to investigate the cytotoxicity effect of ethanol on HepG2 cells and differentiating nonalcoholic steatohepatitis (NASH) from alcoholic liver disease, indicating that the technique is promising for the application in the cell biological and clinical fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fast analysis of ranitidine is of clinical importance in understanding its efficiency and a patient's treatment history. In this paper, a novel determination method for ranitidine based on capillary electrophoresis-electrochemiluminescence detection is described. The conditions affecting separation and detection were investigated in detail. End-column detection of ranitidine in 5 mM Ru(bpy)(3)(2+) solution at applied voltage of 1.20 V was performed. Favorable ECL intensity with higher column efficiency was achieved by electrokinetic injection for 10 s at 10 kV. The R.S.D. values of ECL intensity and migration time were 6.38 and 1.84% for 10(-4) M and 6.01 and 0.60% for 10(-5) M, respectively. A detection limit of 7 x 10(-8) M (S/N = 3) was achieved. The proposed method was applied satisfactorily to the determination of ranitidine in urine in 6 min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describe a Ru(bpy)(3)(2+) based electrochemiluminescence (ECL) method to detect procyclidine in human urine following separation by capillary electrophoresis (CE). An ECL detection cell was designed for post-column addition of Ru(bpy)(3)(2+). Parameters affecting separation and detection were optimized, leading to a detection limit of 1 x 10(-9) mol/l in an on-capillary stacking mode. For application in urine, a cartridge packed with slightly acidic cation-exchange resin was used to eliminate the matrix effects of urine and improve the detection sensitivity. Extraction recovery was nearly 90%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three beta -blockers (propranolol, timolol, acebutolol) were separated by capillary electrophoresis (CE) and detected by end-column electrochemical detection (EC). In the present work, a carbon fiber (33 mum) electrode was used as the working electrode. The effect of the buffer concentration, buffer pH, detection potential and separation voltage on the separation of analytes and behavior of electrochemical detection was systematically investigated. The optimum conditions determined were as following: 40 cm length, 25 mum i.d. capillary; 17.5 kV separation voltage; 2 s injection at 15 kV; 70mM phosphate buffer, pH 3.5; detection potential + 1.2V (vs. Ag/AgCl). Under these conditions, the linear ranges of beta -blockers were over three orders of magnititude and the low detection limit of 10(-8)M was obtained. This method was also applied to detect the simulated urine sample.