132 resultados para Li, Shangyin, 813-838.


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

利用HIRFL提供的50MeV/u的~(13)C束流轰击Be靶,通过RIBLL选择出放射性核素~(11)Li.实验采用透射法测量了25—45MeV/u的~(11)Li在~(28)Si靶上的反应总截面.采用双参数Gauss密度分布形式,利用Glauber模型很好地拟合了高能和中能区的~(11)Li实验数据,并从密度分布中提取了核的物质均方根半径.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEECAS SKLLQG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用交叉束方法 ,利用负离子源产生的 3— 19keV的Li- 和Na- 轰击惰性气体靶He ,Ne和Ar ,通过静电偏转和位置灵敏探测器区分碰撞后中性粒子束和负离子束 ,测量了不同碰撞系统的中性粒子计数与相应入射负离子计数的比值R(E) ,并得到R(E)与入射负离子能量、负离子种类和靶原子种类的关系 .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

基于自相似结构壳模型,并考虑到单粒子轨道的均方根半径的振动,提出了尺度共振模型。在尺度共振模型中,考虑了晕中子轨道的尺度共振和核实表面的尺度共振。用尺度共振模型成功地计算了~(11)Be和~(11)Li的激发谱。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neutron-rich nucleus Li-11 is separated by the radioactive ion beam line RIBLL at HIRFL from the breakup of 50MeV/u C-13 on Be target. The total reaction cross sections for Li-11 at energies range from 25 to 45MeV/u on Si target have been measured by using the transmission method. The experimental data at high and low energies can be fitted well by Glauber model using two Gauss density distribution. The matter radius of Li-11 was also deduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to estimate the acute effects of low dose C-12(6+) ions or X-ray radiation on human immune function. The human peripheral blood lymphocytes (HPBL) of seven healthy donors were exposed to 0.05 Gy C-12(6+) ions or X-ray radiation and cell responses were measured at 24 h after exposure. The cytotoxic activities of HPBL were determined by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT); the percentages of T and NK cells subsets were detected by flow cytometry; mRNA expression of interleukin (IL)-2, tumor necrosis factor (TNF)-alpha and interferon (IFN)-gamma were examined by real time quantitative RT-PCR (qRT-PCR); and these cytokines protein levels in supematant of cultured cells were assayed by enzyme-linked immunosorbent assays (ELISA). The results showed that the cytotoxic activity of HPBL, mRNA expression of IL-2, IFN-gamma and TNF-alpha in HPBL and their protein levels in supernatant were significantly increased at 24 h after exposure to 0.05 Gy C-12(6+) ions radiation and the effects were stronger than observed for X-ray exposure. However, there was no significant change in the percentage of T and NK cells subsets of HPBL. These results suggested that 0.05 Gy high linear energy transfer (LET) C-12(6+) radiation was a more effective approach to host immune enhancement than that of low LET X-ray. We conclude that cytokines production might be used as sensitive indicators of acute response to LDL (C) 2009 COSPAR. Published by Elsevier Ltd. All rights reserved.