218 resultados para Heavy metal ions
Resumo:
Mapping the spatial distribution of contaminants in soils is the basis of pollution evaluation and risk control. Interpolation methods are extensively applied in the mapping processes to estimate the heavy metal concentrations at unsampled sites. The performances of interpolation methods (inverse distance weighting, local polynomial, ordinary kriging and radial basis functions) were assessed and compared using the root mean square error for cross validation. The results indicated that all interpolation methods provided a high prediction accuracy of the mean concentration of soil heavy metals. However, the classic method based on percentages of polluted samples, gave a pollution area 23.54-41.92% larger than that estimated by interpolation methods. The difference in contaminated area estimation among the four methods reached 6.14%. According to the interpolation results, the spatial uncertainty of polluted areas was mainly located in three types of region: (a) the local maxima concentration region surrounded by low concentration (clean) sites, (b) the local minima concentration region surrounded with highly polluted samples; and (c) the boundaries of the contaminated areas. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Different effects of divalent metal ions on electrochemiluminescence (ECL) sensor with Ru(bPY)(3)(2+) immobilized in Eastman-AQ membrane were investigated. Mg2+,Ca2+ and Fe2+ can elevate the ECL of Ru(bpY)(3)(2+)/proline; while metal ions that underwent redox reactions on the electrode such as Mn2+ and Co2+ presented intensive quenching effects on Ru(bpy)(3)(2+) ECL. Also, the quenching effect of Mn2+ on the ECL sensor with Ru(bpY)(3)(2+) immobilized in Eastman-AQ membrane enhanced to about 30-folds compared with the case that Ru(bpy)(3)(2+) was dissolved in phosphate buffer, and the enhanced quenching effects of Mn2+ were studied.
Resumo:
Small molecules are difficult to detect by conventional surface plasmon resonance (SPR) spectroscopy due to the fact that the changes in the refractive index resulted from the binding process of small biomolecules are quite small. Here, we report a simple and effective method to detect small biomolecule using SPR spectroscopy and electrochemistry by catalyzed deposition of metal ions on SPR gold film. As an example, the ascorbic acid-mediated deposition of Ag on gold film was monitored by in situ SPR spectrum. The deposition of Ag atom on gold film resulted in an obvious decrease of depth in SPR angular scan curves of reflectance intensity and minimum reflectivity angle. The depth change of the SPR reflectance intensity and minimum reflectivity angle curves mainly relied on the amount of Ag atom deposited on gold film that can be controlled by the concentration of ascorbic acid. By monitoring the deposition of Ag atom on gold film, ascorbic acid was detected in the concentration range of 2 x 10(-5) M to 1 x 10(-3) M. After each of detections, the SPR sensor surface was completely regenerated by a potential step that stripped off the Ag atom. Furthermore, the regeneration process of the sensor surface provides the feasibility for detecting the concentration of ascorbic acid by electrochemical method.
Resumo:
Four novel Ir-III and Pt-II complexes with cyclometalated ligands bearing a carbazole framework are prepared and characterized by elemental analysis, NMR spectroscopy, and mass spectrometry. Single-crystal X-ray diffraction studies of complexes 1, 3, and 4 reveal that the 3- or 2-position C atom of the carbazole unit coordinates to the metal center. The difference in the ligation position results in significant shifts in the emission spectra with the changes in wavelength being 84 nm for the Ir complexes and 63 nm for the Pt complexes. The electrochemical behavior and photophysical properties of the complexes are investigated, and correlate well with the results of density functional theory (DFT) calculations. Electroluminescent devices with a configuration of ITO/NPB/CBP:dopant/BCP/AlQ(3)/LiF/Al can attain very high efficiencies.
Resumo:
As a kind of novel green solvent, Room Temperature Ionic Liquids (RTILs) have been paid ever-increasing attentions in RTIL-based extraction for metal separation, since they have many unique proper-ties, such as non-volatile and non-flammable. The progress of that is mainly composed of the partition properties, mechanisms, defects, overcome methods and forecasts of the processes on the environmental analytical chemistry, has been reviewed.
Resumo:
In this paper, a calix[4]arene derivative, 5,11,17,23-butyl-25,26,27,28-tetra-(ethanoxycarbonyl)-methoxy-calix[4]arene (L), is investigated as a host to recognize alkali metal ions (Li+, Na+, K+, Rb+ and Cs+) at the interface between two immiscible electrolyte solutions (ITIES). Well-defined cyclic voltammograms are obtained at the micro- and nano-water \ 1,2-dichloroethane (W \ DCE) interfaces supported at micro- and nano-pipets.
Resumo:
Equilibrium distributions of cobalt(II), nickel(II), zinc(II), cadmium(II), and copper(II) have been studied in the adsorption with extraction resin containing 1-hexyl-4-ethyloctyl isopropylphosphonic acid (HEOPPA) as an extractant from chloride medium. The distribution coefficients are determined as a function of pH. The data are analyzed both graphically and numerically. The extraction of the metal ions can be explained assuming the formation of metal complexes in the resin phase with a general composition ML2(HL)(q). The adsorbed species of the metal ions are proposed to be ML2 and the equilibrium constants are calculated. The efficiency of the resin in the separation of the metal ions is provided according to the separation factors values. The separation of Zn from Ni, Cd, Cu, Co, and Co from Ni, Cd, Cu with the resin is determined to be available. Furthermore, Freundlich's isothermal adsorption equations and thermodynamic quantities, i.e., DeltaG, DeltaH, and DeltaS are determined.
Resumo:
As counterions of DNA on mica, Mg2+, Ca2+, Sr2+ and Ba2+ were used for,clarifying whether DNA molecules equilibrate or are trapped on mica surface. End to end distance and contour lengths were determined from statistical analysis of AFM data. It was revealed that DNA molecules can equilibrate on mica when Mg2+, Ca2+ and Sr2+ are counterions. When Ba2+ is present, significantly crossovered DNA molecules indicate that it is most difficult for DNA to equilibrate on mica and the trapping degree is different under different preparation conditions. In the presence of ethanol, using AFM we have also observed the dependence of B A conformational transition on counterion identities. The four alkaline earth metal ions cause the B-A transition in different degrees, in which Sr2+ induces the greatest structural transition.
Resumo:
For the 4f(N-1)5d configuration the Coulomb interaction between f and d electrons was parameterized by F-k(fd) with K = 2, 4, and G(K)(fd) with K = 1, 3, 5. The spin-orbit interaction for 4f and 5d electrons can be parameterized by xi (f) and xi (d) respectively, which can be compounded into one lambda : lambda = axi (f) + bxi (d), where a and b are the corresponding coefficients. The energy expressions of H-e(fd) of the chief low-energy levels of 4f(N-) (1)5d configuration for heavy lanthanide ions were calculated and the corresponding spin-orbit parameters lambda were also given in LS coupling, which are profitable in analyzing the spectra of the heavy lanthanide ions.
Resumo:
Such physicochemical properties of sec-nonylphenoxy acetic acid (CA-100) as the solubility in water, acid dissociation constant in water, dimerization constant in heptane, and distribution constant in organic solvent-water were measured by two-phase titration. The extraction behaviors of scandium (III), yttrium (III), lanthanides (III), and divalent metal ions from hydrochloric acid solutions with CA-100 in heptane have been investigated, and the possibilities of separating scandium (yttrium) from lanthanides and divalent metal ions have been carefully discussed. The stoichiometries of the extracted metal complexes were investigated by the slope-analysis technique. The effect of the nature of diluent on the extraction of yttrium (III) with CA100 has been studied and correlated with the dielectric constant.
Resumo:
Red shift and quenching effects of the fluorecence spectra of polyquinoline (PQH) solutions in different solvents are observed upon the addition of metal ions, which demonstrates the extraordinary solvent effects on metal-ion recognition and sensing ability (including sensitivity and selectivity) of PQH.
Resumo:
In this paper, a novel monoaza-B15C5 derivative, N-(2-tosylamino)-isopentyl-monoaza-15-crown-5 (L), is used as an ionophore to facilitate alkali metal cations transfer across a water/1,2-dichloroethane (W/DCE) interface. Well-defined voltammetric behaviors are observed at the polarized W/DCE interfaces supported at micro- and nano-pipets except Cs+. The diffusion coefficient of this ionophore in the DCE phase is calculated to be equal to (3.3+/-0.2) x 10(-6) cm(2) s(-1). The experimental results indicate that a 1:1 (metal: ionophore) complex is formed at the interface with a TIC/TID mechanism. The selectivity of this ionophore towards alkali ions follows the sequence Na+ > Li+ > K+ > Rb+ > Cs+. The logarithm of the association constants (log beta(1)(0)) of the LiL+, NaL+, KL+ and RbL+ complexes in the DCE phase are calculated to be 10.6, 11.6, 9.0 and 7.1, respectively. The kinetic parameters are determined by steady-state voltammograms using nanopipets. The standard rate constants (k(0)) for Li+, Na+, K+ and Rb+ transfers facilitated by L are 0.54+/-0.05, 0.63+/-0.09, 0.51+/-0.04 and 0.46+/-0.06 cm s(-1), respectively. The pH values of aqueous solution have little effect on the electrochemical behaviors of these facilitated processes. The results predicate that this new type of ionophore might be useful to fabricate electrochemical sensor of sodium ion.