58 resultados para Harmonic suppressor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Second-harmonic generation was observed in Ge(20)AS(25)S(55) chalcogenide glass irradiated by an electron beam. The second-harmonic intensity increased with increasing electron-beam current and accelerating voltage. The second-harmonic generation in Ge20As25S55 glass was caused by the space-charge electrostatic field that was generated by irradiation of an electron beam. Second-order nonlinearity chi ((2)) as great as 0.8 pm/V was obtained. The results of measurements of thermally stimulated depolarization current indicated that the glass was poled in the thin layers of its surface (several micrometers) and that the nonlinearity was stable. (C) 2001 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on photoinduced second-harmonic generation (SHG) in chalcogenide glasses. Fundamental and second-harmonic waves from a nanosecond pulsed Nd:YAG laser were used to induce second-order nonlinearity in chalcogenide glasses. The magnitude of SHG in 20Ge . 20As . 60S glass was 10(4) larger than that of tellurite glass with a composition of 15Nb(2)O(5) . 85TeO(2) (mol.%). Moreover, no apparent decay of photoinduced SHG in 20Ge . 20As . 60S glass was observed after optical poling at room temperature. We suggest that the large and stable value of X-(2) is due to the induced defect structures and large X-(3) of the chalcogenide glasses. (C) 2001 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tumor suppressor p53 is a master sensor of stress. Two human-specific polymorphisms, p53 codon 72 and MDM2 SNP309, influence the activities of p53. There is a tight association between cold winter temperature and p53 Arg72 and between low UV intensity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We develop a swept frequency method for measuring the frequency response of photodetectors; (PDs) based on harmonic analysis. In this technique, a lightwave from a laser source is modulated by a radio-frequency (RF) signal via a Mach-Zehnder LiNbO3 modulator, and detected by a PD under test. The measured second-order harmonic of the RF signal contains information of the frequency responses and nonlinearities of the RF source, modulator, and PD. The frequency response of the PD alone is obtained by deducting the known frequency responses and nonlinearities of the RF source and modulator. Compared with the conventional swept frequency method, the measurement frequency range can be doubled using the proposed method. Experiment results show a good agreement between the measured results and those obtained using other techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the solid-state double-dot interferometer, the phase shifted interference pattern induced by the interplay of inter-dot Coulomb correlation and multiple reflections is analyzed by harmonic decomposition. Unexpected result is uncovered, and is discussed in connection with the which-path detection and electron loss. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A second-harmonic generation (SHG) is predicted for the Bogoliubov excitations in a two-component Bose-Einstein condensate. It is shown that, because the linear dispersion curve of the excitations displays two branches, the phase-matching condition for the SHG can be fulfilled if the wave vectors and frequencies of fundamental and second-harmonic waves are selected suitably from different branches. The nonlinearly coupled envelope equations for the SHG are derived by using a method of multiple scales. The explicit solutions of these envelope equations are provided and the conversion efficiency of the SHG is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The real-time monitoring of the second-harmonic generation (SHG) was used to optimize the poling condition and to study the nonlinear optical (NLO) properties of the polyetherketone (PEK-c) guest-host polymer films. The high second-order NLO coefficient chi(33)((2)) = 11.02 pm/v measured at 1.064 mu m was achieved when the weight percent of DR1 guest in the polymer system is 20%. The NLO activity of the poled DR1/PEK-c polymer film can maintain more than 80% of its initial value when temperature is under 100 degrees C, and the normalized second-order NLO coefficient can maintain more than 85% after 2400 s at 80 degrees C. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a harmonic mode-locked ytterbium-doped fibre ring laser, which consists of a polarization-sensitive isolator, two polarization controllers, two 976 nm laser diodes as the pump source and a two-segment ytterbium-doped fibre. Utilizing an additive pulse mode-locked technique based on nonlinear polarization evolution, the ytterbium-doped fibre laser can operate in mode-locked state by adjusting the position of polarization controllers. The cavity fundamental repetition rate is 23.78 MHz. We also observe the second- and third-harmonic mode locking in the normal dispersion region, and their repetition rates are 47.66 MHz and 71.56 MHz, respectively. Over-driving of the saturable absorber in the harmonic mode-locking pulse is analysed and discussed in detail.