32 resultados para Gating
Resumo:
A read-out and data acquisition system for the outputs of multi-channel spectroscopy amplifiers is introduced briefly in this paper.The 16-channel gating integrator/multiplexer developed by us and PXI-DAQ card are used to construct this system.A virtual instrument system for displaying,indicating,measuring and recording of output waveform is accomplished by integrating the PC,hardware,software together flexibly based on the Lab Windows/CVI platform in our read-out and data acquisition system.In this system,...中文文摘:简要介绍一个针对多路谱仪放大器的读出与数据采集方法与系统。该系统基于16通道门积分/选通输出电路和通用PXI-DAQ卡构建。利用Lab Windows/CVI平台构建虚拟仪器,灵活地将计算机、硬件、软件结合起来,设计了一个读出与数据采集系统。在该系统中,一个ADC通道可以面对16个谱仪放大器的输出,有效地提高了系统的集成度,降低了数据采集系统的成本。该设计为利用通用型谱仪放大器构建数百参数的信号读出与数据采集系统提供了一种新的方法。通过实验验证,证明该系统具有智能化、可靠性高、实时性强、成本低等优点。
Resumo:
A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.