113 resultados para Fiber-based counterparts


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Si-based SiGe/Si strained MQW long-wavelength photodetectors (PD) with cycle type (Ring Shape) waveguide (CWG) and resonant-cavity-enhanced (RCE) structure have been investigated for the first time for improving the quantum efficiency and response time. The results show that the responsivities are higher than that of conventional PD with a same Ge content reported previously. In addition, RCE-PD has an obvious narrow band response with FWHM less than 6nm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this contribution we report the research and development of 1.55 mu m InGaAsP/InP gain-coupled DFB laser with an improved injection-carrier induced grating and of high performance 1.3 mu m and 1.55 mu m InGaAsP/InP FP and DFB lasers for communications. Long wavelength strained MQW laser diodes with a very low threshold current (7-10 mA) have been fabricated. Low pressure MOVPE technology has been employed for the preparation of the layered structure. A novel gain-coupled DFB laser structure with an improved injection-carrier modulated grating has been proposed and fabricated. The laser structures have been prepared by hybrid growth of MOVPE and LPE techniques and reasonably good characteristics have been achieved for resultant lasers. High performance 1.3 mu m and 1.55 mu m InGaAsP/InP DFB lasers have successfully been developed for CATV and trunk line optical fiber communication.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We propose a simple approach to generate a high quality 10 GHz 1.9 ps optical pulse train using a semiconductor optical amplifier and silica-based highly nonlinear fiber. An optical pulse generator based on our proposed scheme is easy to set up with commercially available optical components. A 10 GHz, 1.9 ps optical pulse train is obtained with timing jitter as low as 60 fs over the frequency range 10 Hz-1 MHz. With a wavelength tunable CW laser, a wide wavelength tunable span can be achieved over the entire C band. The proposed optical pulse generator also can operate at different repetition rates from 3 to 10 GHz.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Switchable multiwavelength fiber laser outputs with a wide tuning range are experimentally observed in an ultralong cavity. Because of the long spooled single-mode fiber and filter effect of the cavity, multiwavelength lasers with the spacing of similar to 14.5 nm are obtained. The proposed fiber laser has the capacity of simultaneously emitting the three wavelengths. By means of adjusting the polarization controllers, the arbitrary single- and dual-wavelength operations are achieved in our laser. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3485754]

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A highly sensitive microstructured polymer optical fiber (MPOF) probe for hydrogen peroxide was made by forming a rhodamine 6G-doped titanium dioxide film on the side walls of array holes in an MPOF. It was found that hydrogen peroxide only has a response to the MPOF probe in a certain concentration of potassium iodide in sulfuric acid solution. The calibration graph of fluorescence intensity versus hydrogen peroxide concentration is linear in the range of 1.6 x 10(-7) mol/L to 9.6 x 10(-5) mol/L. The method, with high sensitivity and a wide linear range, has been applied to the determination of trace amounts of hydrogen peroxide in a few real samples, such as rain water and contact lens disinfectant, with satisfactory results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel flow injection optical fiber biosensor for glucose based on luminol electrochemiluminescence (ECL) is presented. The sol-gel method is introduced to immobilize glucose oxidase (GOD) on the surface of a glassy carbon electrode. After optimization of the working conditions, glucose could be quantitated in the concentration ranges between 50 muM and 10 mM with a detection limit of around 26 muM. Signal reproducibility was about 3.62% relative standard deviation for 11 replicated measurements of 0.1 mM glucose. The ECL biosensor also showed good selectivity and operational stability. The proposed method can be applied to determination of glucose in soft drink samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An optical fiber bienzyme sensor based on the luminol chemiluminescent reaction was developed and demonstrated to be sensitive to glucose. Glucose oxidase (GOD) and horseradish peroxidase (HRP) were co-immobilized by microencapsulation in a sol-gel film derived from tetraethyl orthosilicate(TEOS). The calibration plots for glucose were established by the optical fiber glucose sensor fabricated by attaching the bienzyme silica gel onto the glass window of the fiber bundle. The linear range was 0.2-2 mmol/L and the detection limit was approximately 0.12 mmol/L. The relative standard deviation was 5.3% (n = 6). The proposed biosensor was applied to glucose assay in ofloxacin injection successfully.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Separation of Ce(IV) and RE(III) was investigated by hollow fiber membrane-based extraction with contercurrent recirculating operation. The mass transfer coefficients of Ce(IV) and RE(III) and the effective factors to them were tested. The results show the mass transfer coefficient of Ce(IV) is larger than that of RE(III), and their mass transfer mechanism is different. The mass transfer of Ce(IV) was controlled by the resistance in water critical layer due to its more rapid interfacial reaction rate and larger distribution coefficient, which was different from RE(III) mass transfer with a slow interfacial reaction rate and small distribution coefficient. Ce(IV) was separated from the mixed solution of Ce(IV) and RE(III) by means of the difference of their mass transfer rates.