115 resultados para DM FC


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The experimental and theoretical investigations into the head-on collision between a landing droplet with another one resting on the PDMS substrate were addressed in this talk. The colliding process of the two droplets was recorded with highspeed camera. Four different responses after collision were observed in our experiments: complete rebound, coalescence, partial rebound with conglutination, and coalescence accompanied by conglutination. The contact time between the two colliding droplets was found to be in the range of 10-20 milliseconds. For the complete bouncing case, Hertz contact model was applied to estimate the contact time of the binary head-on colliding droplets with both the droplets considered as elastic bodies. The estimated contact time was in good agreement with the experimental result.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two research projects on pool boiling in microgravity have been conducted aboard the Chinese recoverable satellites. Ground-based experiments have also been performed both in normal gravity and in short-term microgravity in the Drop Tower Beijing. Steady boiling of R113 on thin platinum wires was studied with a temperature-controlled heating method, while quasi-steady boiling of FC-72 on a plane plate was investigated with an exponentially increasing heating voltage. In the first case, slight enhancement of heat transfer is observed in microgravity, while diminution is evident for high heat flux in the second one. Lateral motions of bubbles on the heaters are observed before their departure in microgravity. The surface oscillation of the merged bubbles due to lateral coalescence between adjacent bubbles drives it to detach from the heaters. The Marangoni effect on the bubble behavior is also discussed. The perspectives for a new project DEPA-SJ10, which has been planned to be flown aboard the Chinese recoverable satellite SJ-10 in the future, are also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文以丝状加热表面上的池沸腾传热现象为主要研究对象,利用地面常重力实验,研究了不同热丝直径、不同过冷度下((0~40℃)的丝状加热片面FC-72液体和丙酮液体的池沸腾传热特性。 本文利用自主研发的一套可控过冷度池沸腾实验设备,使用纯度为99.99%的铂丝同时作为加热元件和测温元件,加热丝直径分别为0.06mm、0.025mm、0.1mm,长度为30mm。实验采用控制加热电压按阶梯形式增长或下降(时间常数约20s)的稳态加热方式。 实验所得单相自然对流传热数据同Kuehn-Goldstein(1976)换热公式预测结果具有较高的一致性,说明实验设备可靠、实验数据可信。 实验过程中发现,在相同压力条件下,随着过冷度的增加,沸腾传热强化;CHF值在低过冷度时呈线性增加,然后增加趋势变缓。丙酮实验中,0.06mm热丝和0.1mm热丝在低过冷度(2.5~10℃)情况下都出现了从自然对流直接进入双膜态现象,不过,当降低加热电压时,膜态沸腾仍转化为核态沸腾,此时继续增高加热电压,沸腾曲线仍沿常规核态沸腾曲线上升至CHF后,再转换为膜态沸腾。对于同等直径热丝,无论核态沸腾或双膜态沸腾,在丙酮中所产生汽泡尺寸明显偏大。 过冷沸腾中,临界热流随过冷度的增加呈现出非线性依赖关系。在低过冷度线性区,FC-72中实验结果与几种低过冷度线性模型较一致;丙酮中实验结果 随 变化斜率明显高于几种低过冷度线性模型的预测,显示出对尺度的依赖关系。这说明在小Bond数时存在尺度效应对过冷度的影响,即对于小Bond数情况过冷度和尺度效应的耦合作用是非常重要的。 饱和沸腾中,FC-72和丙酮的CHF值随热丝直径的减小而不断增加,其中,FC-72的CHF数值尽管比LD模型预测结果略低,但定性地依然可用LD模型进行描述,尽管相比于LD模型原始的适用范围 已扩大了1~2个数量级;但丙酮的实验数据却远小于LD模型预测结果。综合分析表明,尽管热丝直径相同,但物性的差异使得FC-72和丙酮实验中的数据点分别处于不同的尺度特征区域,反映了小Bond数情形下分区准则的物性依赖性。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pool boiling of degassed FC-72 on a plane plate heater has been studied experimentally in microgravity. A quasi-steady heating method is adopted, in which the heating voltage is controlled to increase exponentially with time. Compared with terrestrial experiments, bubble behaviors are very different, and have direct effect on heat transfer. Small, primary bubbles attached on the surface seem to be able to suppress the activation of the cavities in the neighborhoods, resulting in a slow increase of the wall temperature with the heat flux. For the high subcooling, the coalesced bubble has a smooth surface and a small size. It is difficult to cover the whole heater surface, resulting in a special region of gradual transitional boiling in which nucleate boiling and local dry area can co-exist. No turning point corresponding to the transition from nucleate boiling to film boiling can be observed. On the contrary, the surface oscillation of the coalesced bubble at low subcooling may cause more activated nucleate sites, and then the surface temperature may keep constant or even fall down with the increasing heat flux. Furthermore, an abrupt transition to film boiling can also be observed. It is shown that heat transfer coefficient and CHF increase with the subcooling or pressure in microgravity, as observed in normal gravity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For efficiently cooling electronic components with high heat flux, experiments were conducted to study the flow boiling heat transfer performance of FC-72 over square silicon chips with the dimensions of 10 × 10 × 0.5 mm3. Four kinds of micro-pin-fins with the dimensions of 30 × 60, 30 × 120, 50 × 60, 50 × 120 μm2 (thickness, t × height, h) were fabricated on the chip surfaces by the dry etching technique for enhancing boiling heat transfer. A smooth surface was also tested for comparison. The experiments were made at three different fluid velocities (0.5, 1 and 2 m/s) and three different liquid subcoolings (15, 25 and 35 K). The results were compared with the previous published data of pool boiling. All micro-pin-fined surfaces show a considerable heat transfer enhancement compared with a smooth surface. Flow boiling can remarkably decrease wall superheat compared with pool boiling. At the velocities lower than 1 m/s, the micro-pin-finned surfaces show a sharp increase in heat flux with increasing wall superheat. For all surfaces, the maximum allowable heat flux, qmax, for the normal operation of LSI chips increases with fluid velocity and subcooling. For all micro-pin-finned surfaces, the wall temperature at the critical heat flux (CHF) is less than the upper limit for the reliable operation of LSI chips, 85◦C. The largest value of qmax can reach nearly 148 W/cm2 for micro-pin-finned chips with the fin height of 120 μm at the fluid velocity of 2 m/s and the liquid subcooling of 35 K. The perspectives for the boiling heat transfer experiment of the prospective micro-pin-finned sur- faces, which has been planned to be made in the Drop Tower Beijing/NMLC in the future, are also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of existing strategies to engineer active antibody is to link VH and VL domains via a linker peptide. How the composition, length, and conformation of the linker affect antibody activity, however, remains poorly understood. In this study, a dual approach that coordinates molecule modeling, biological measurements, and affinity evaluation was developed to quantify the binding activity of a novel stable miniaturized anti-CD20 antibody or singlechain fragment variable (scFv) with a linker peptide. Upon computer-guided homology modeling, distance geometry analysis, and molecular superimposition and optimization, three new linker peptides PT1, PT2, and PT3 with respective 7, 10, and 15 residues were proposed and three engineered antibodies were then constructed by linking the cloned VH and VL domains and fusing to a derivative of human IgG1. The binding stability and activity of scFv-Fc chimera to CD20 antigen was quantified using a micropipette adhesion frequency assay and a Scatchard analysis. Our data indicated that the binding affinity was similar for the chimera with PT2 or PT3 and ~24-fold higher than that for the chimera with PT1, supporting theoretical predictions in molecular modeling. These results further the understanding in the impact of linker peptide on antibody structure and activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文实验研究了平板加热面FC-72液体的准稳态池沸腾传热现象,利用地面常重力实验、SJ-8卫星搭载微重力实验等手段,分析了不同重力、压力及过冷度条件下平板加热面上的池沸腾传热特性.微重力条件下,相近压力或过冷度时,传热系数和CHF随过冷度或压力增大而增大.相对常重力,传热曲线明显变缓,沸腾起始时的壁面过热度降低,CHF仅为常重力的40%或更低.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Researches on two-phase flow and pool boiling heat transfer in microgravity, which included groundbased tests, flight experiments, and theoretical analyses, were conducted in the National Microgravity Laboratory/CAS. A semi-theoretical Weber number model was proposed to predict the slug-to-annular flow transition of two-phase gas–liquid flows in microgravity, while the influence of the initial bubble size on the bubble-to-slug flow transition was investigated numerically using the Monte Carlo method. Two-phase flow pattern maps in microgravity were obtained in the experiments both aboard the Russian space station Mir and aboard IL-76 reduced gravity airplane. Mini-scale modeling was also used to simulate the behavior of microgravity two-phase flow on the ground. Pressure drops of two-phase flow in microgravity were also measured experimentally and correlated successfully based on its characteristics. Two space experiments on pool boiling phenomena in microgravity were performed aboard the Chinese recoverable satellites. Steady pool boiling of R113 on a thin wire with a temperature-controlled heating method was studied aboard RS-22, while quasi-steady pool boiling of FC-72 on a plate was studied aboard SJ-8. Ground-based experiments were also performed both in normal gravity and in short-term microgravity in the drop tower Beijing. Only slight enhancement of heat transfer was observed in the wire case, while enhancement in low heat flux and deterioration in high heat flux were observed in the plate case. Lateral motions of vapor bubbles were observed before their departure in microgravity. The relationship between bubble behavior and heat transfer on plate was analyzed. A semi-theoretical model was also proposed for predicting the bubble departure diameter during pool boiling on wires. The results obtained here are intended to become a powerful aid for further investigation in the present discipline and development of two-phase systems for space applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present in this paper the results obtained from a parabolic flight campaign regarding the contact angle and the drop interface behavior of sessile drops created under terrestrial gravity (1g) or in microgravity (mu g). This is a preliminary study before further investigations on sessile drops evaporation under microgravity. In this study, drops are created by the mean of a syringe pump by injection through the substrate. The created drops are recorded using a video camera to extract the drops contact angles. Three fluids have been used in this study : de-ionized water, HFE-7100 and FC-72 and two heating surfaces: aluminum and PTFE. The results obtained evidence the feasibility of sessile drop creation in microgravity even for low surface tension liquids (below 15 mN m (-aEuro parts per thousand 1)) such as FC-72 and HFE-7100. We also evidence the contact angle behavior depending of the drop diameter and the gravity level. A second objective of this study is to analyze the drop interface shape in microgravity. The goal of the these experiments is to obtain reference data on the sessile drop behavior in microgravity for future experiments to be performed in an French-Chinese scientific instrument (IMPACHT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The transient evolution processes and steady outputs of continuous wave lasing without inversion (LWI) and self-pulsing LWI in a resonant open V type three-level system are studied. It was found that the two kinds of LWI have some obvious differences not only from the steady outputs but also from the transient evolution processes. The effects of the unsaturated gain coefficient, cavity loss coefficient, ratio of the atomic injection rates and atomic exit rate on the transient evolution processes and steady outputs are discussed.