49 resultados para Adaptive music


Relevância:

20.00% 20.00%

Publicador:

Resumo:

For a class of nonlinear dynamical systems, the adaptive controllers are investigated using direction basis function (DBF) in this paper. Based on the criterion of Lyapunov' stability, DBF is designed which guarantees that the output of the controlled system asymptotically tracks the reference signals. Finally, the simulation shows the good tracking effectiveness of the adaptive controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An adaptive phase-locked loop (PLL) frequency synthesizer architecture for reducing reference sidebands at the output of the frequency synthesizer is described. The architecture combines two tuning loops: one is the main loop for locking the PLL frequency synthesizer and operating all the time, the other one is auxiliary loop for reducing reference sidebands and operating only when the main loop is closely locked. A 1.8V 1GHz fully integrated CMOS dual-loop frequency synthesizer is designed in a 0.18um CMOS process. The suppression of the reference sidebands of the proposed frequency synthesizer is 13.8dB more than that of the general frequency synthesizer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new adaptive state estimation algorithm, namely adaptive fading Kalman filter (AFKF), is proposed to solve the divergence problem of Kalman filter. A criterion function is constructed to measure the optimality of Kalman filter. The forgetting factor in AFKF is adaptively adjusted by minimizing the defined criterion function using measured outputs. The algorithm remains convergent and tends to be optimal in the presence of model errors. It has been successfully applied to the headbox of a paper-making machine for state estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the effects of pre-exposure of mouse testis to low-dose C-12(6+) ions on cytogenetics of spermatogonia and spermatocytes induced by subsequent high-dose irradiation. the testes of outbred Kun-Ming strain mice were irradiated with 0.05 Gy of C-12(6+) ions as the pre-exposure dose, and then irradiated with 2 Gy as challenging dose at 4 h after per-exposure. Poly(ADP-ribose) polymerase (PARPs) activity and PARP-1 protein expression were respectively measured by using the enzymatic and Western blot assays at 4 h after irradiation; chromosomal aberrations in spermatogonia and spermatocytes were analyzed by the air-drying method at 8 h after irradiation. The results showed that there was a significant increase in the frequency of chromosomal aberrations and significant reductions of PARP activity and PARP-1 expression level in the mouse testes irradiated with 2 Gy of C-12(6+) ions. However, pre-exposure of mouse testes to a low dose of C-12(6+) ions significantly increased PARPs activity and PARP-1 expression and alleviated the harmful effects induced by a subsequent high-dose irradiation. PARP activity inhibitor 3-aminobenzamide (3-AB) treatment blocked the effects of PARP-1 on cytogenetic adaptive response induced by low-dose C-12(6+) ion irradiation. The data suggest that pre-exposure of testes to a low dose of heavy ions can induce cytogenetic adaptive response to subsequent high-dose irradiation. The increase of PARP-1 protein induced by the low-dose ionizing irradiation may be involved in the mechanism of these observations. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brain of the Kun-Ming strain mice were irradiated with 0.05 Gy of C-12(6+) ion or Co-60 gamma-ray as the pre-exposure dose, and were then irradiated with 2 Gy of 12C6+ ion or Co-60 gamma-ray as challenging irradiation dose at 4 h after per-exposure. Body weight and serum growth hormone (GH) concentration were measured at 35th day after irradiation. The results showed that irradiation of mouse brain with 2 Gy of C-12(6+) ion or Co-60 gamma-ray significantly diminished mouse body weight and level of serum GH. The relative biological effectiveness values of a 2 Gy dose of C-12(6+) ion calculated with respect to Co-60 gamma-ray were 1.47 and 1.34 for body weight and serum GH concentration, respectively. Pre-exposure with a low-dose (0.05 Gy) of C-12(6+) ion or Co-60 gamma-ray significantly alleviated reductions of mouse body weight and level of serum GH induced by a subsequent high-dose (2 Gy) irradiation. The data suggested that low-dose ionizing irradiation can induce adaptive hormetic responses to the harmful effects of pituitary by subsequent high-dose exposure.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natl Chiao Tung Univ, Dept Comp Sci

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Huazhong Univ Sci & Technol, Natl Tech Univ Ukraine, Huazhong Normal Univ, Harbin Inst Technol, IEEE Ukraine Sect, I& M/CI Joint Chapter