437 resultados para Emission intensities


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spontaneous emission properties of a single layer organic film in plane optical microcavities were studied. Optical microcavity was formed by a Tris(8-quinolinolato) aluminium (Alq) film sandwiched between a distributed Bragg reflector (DBR) and a Ag metallic reflector. Two kinds of microcavities were devised by using a different DBR structure. Compared with a Alq film, significantly spectral narrowing and intensity enhancement was observed in the two microcavities, which is attributed to the microcavity effect. The spectra characteristics of the two microcavities showed that the structure of DBR has much influence on the emission properties of a microcavity. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The steady-state fluorescence properties of naphthalene-labeled polymers dispersed in poly(methyl methacrylate) (PMMA) cast films were studied under tensile loadings at 80 degreesC. The labeled polymers were composed of methyl methacrylate (MMA) and 1-naphthylmethyl methacrylate (NMMA). Three of the copolymers were used in this work, and the contents of NMMA were 0.59 mol % (CP1), 22.0 mol % (CP2), and 56.7 mol % (CP3), respectively. The fluorescence spectra of the films containing CP1 and CP2were unchanged during elongation. For the film containing CP3, the excited monomer emission of naphthyl groups at around 337 nm decreased with increasing applied tensile strain. The strain enhanced the emission ascribed to the excimer of the naphthyl groups in the region of 390-420 nm. The ratio of fluorescence intensities at 400 nm and 337 mn, I-400/I-337, increased with the applied strain, which indicates that CP3 is a sensitive probe for detecting the structural changes of polymer matrices. The obtained results mean that the excimer-forming sites in the PMMA films during elongation depend both on the applied strain and the concentration of naphthyl groups in the dispersed polymer probes. (C) 2001 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The charactesistics of two-dimension spectra obtained by inductively coupled plasma atomic emission spectrometry (ICP-AES) with charge injection detection (CID) in frequency domain were studied in the present paper. The measurement spectra were Fourier transformed and the frequency distribution of the spectra was obtained. Results showed that the spectra in frequency domain could he divided into two parts:high frequency and low frequency signals. The later stood for measurement spectra and the former for background and noises. However, the high frequecny signals could not be smoothed simply to reduce noises because the background was deteriorated even though the spectral signal did not change significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Binary complexes of europium and terbium with N-propyl-4-carboxyphthalimide (NP) were prepared and characterized. The luminescence behaviors of the lanthanide complexes as well as their doped silica-based composites were investigated by fluorescence spectra. The results indicated that the lanthanide complexes showed fewer emission lines and slightly lower intensities in silica matrix than that of corresponding pure complexes. The lifetimes of the lanthanide complexes became longer when they were incorporated in silica matrix. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article applied [HEH(HEP)] (2-ethyhexyldrogen-2-ethylhexyl phosphonate)extraction chromatography to separate 14 rare earth impurities from ultra-highly pure Er2O3 and Ho2O3, and then the impurities were determined by atomic emission spectrometry. The average percentage recovery for each element is in the range of 70%similar to 140%. The relative standard deviations of the determination are +/-3.3%similar to 2.2%. This method can be applied to the determination of the trace amounts of rare eath impurities in Er2O3 and Ho2O3 with a purity of 99.999 9%-99.999 99%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dye laser based on the soluble conjugated polymer, Poly[1,8-octanedioxy-2,6-dimethoxy-1,4-phenylene-1,2-ethenylene-1, 4-phenylene-1,2-ethenylene-3,5-dimethoxy-1,4-phenylene], has been fabricated. The laser was pumped by light pulses from the third harmonic radiation of an Nd:YAG laser. The lasing was observed in the blue wavelength region with the peak at 450 nm. The threshold energy is about 19 mu J. The energy conversion yield of the laser is about 3.4%. The maximum peak power of the laser output pulse arrives at about 20 kW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Target transformation factor analysis was used to correct spectral interference in inductively coupled plasma atomic emission spectrometry (ICP-BES) for the determination of rare earth impurities in high purity thulium oxide. Data matrix was constructed with pure and mixture vectors and background vector. A method based on an error evaluation function was proposed to optimize the peak position, so the influence of the peak position shift in spectral scans on the determination was eliminated or reduced. Satisfactory results were obtained using factor analysis and the proposed peak position optimization method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the analysis of mussel standard reference material by inductively coupled plasma atomic emission spectrometry( ICP-AES) and inductively coupled plasma mass spectrometry(ICP-MS) was developed. K, Na, Ca, Mg, P, Al, Fe, Zn, Mn and Sr were determined by ICP-AES and As, B, Cd, Co, Cr, Cu, Ga, Ge, Mn, Mo, Ni, Pb, Se, Sr, U and V by ICP-MS, The interference coefficients at the Mn-55, Se-78, Cu-63, Co-59, Ni-58, Ni-60, As-75, Se-77, V-51, Cr-53 and Cr-52 originating from polyatomic ion of the matrix elements (KO)-K-39-O-16, K-39(2), (ArNa)-Ar-40-Na-23, (CaO)-Ca-43-O-16, (CaO)-Ca-42-O-16, (CaO)-Ca-44-O-16, (PO2)-P-31-O-16, (ArCl)-Ar-40-Cl-35, (ArCl)-Ar-40-Cl-37, (ClO)-Cl-35-O-16, (ClO)-Cl-37-O-16 and (ArC)-Ar-40-C-12 were determined under the selected operation parameters. The major matrix elements, such as K, Na and Ca, result in the suppression of analytes signals. The apparent concentration at the significant biological element which was produced by the different digestion methods, (.) HNO3 + H2O2 (3 + 2), HNO3 + HClO4 (3 + 0.5) and HNO3 + H2SO4 (3 + 0.5),was determined. The sample digested by HNO3 + H2O2 did not give rise to interfere on the analyte, and the backgrounds of Se-77, Ga-69, Zn-67, As-75, V-51, Cr-53 and Cr-52 were increased by HNO3 + HClO4 digestion method, that affected the determination of these elements, especially the monoisotope As and V. Sample digested by HNO3 + H2SO4 increased the backgrounds at Cu-65, Zn-64 and Zn-67. Detection limits of ICP-AES are 0.001 similar to 0.75 mg/L and those of ICP-MS are 0.005 similar to 1.01 mu g/L. The relative standard derivations of ICP-AES and ICP-MS are 2.7% similar to 12.8%, 3.4% similar to 24.8%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ternary complexes of europium and terbium with paraaminobenzoic acid and 1,10-phenanthroline (Eu(p-ABA)(3). phen . 2H(2)O and Tb(p-ABA)(3). phen . 2H(2)O, where p-HABA = paraaminobenzoic acid and phen = 1,10-phenanthroline) were introduced into a silica matrix by sol-gel method. The luminescence behavior of the complexes in silica gels was studied in comparison with the. corresponding solid-state complexes by means of emission, excitation spectra, and Lifetimes. Within the range of effective dopant concentrations, the luminescence intensities of rare-earth complexes in silica gel increase with the increasing of their dopant concentration. The lifetimes of rare-earth ions (Eu3+ and-Tb3+) in silica gel doped with europium and terbium complexes become longer than those in pure complexes. Very small amounts of rare-earth complexes doped in silica gel matrix can exhibit excellent luminescence properties, (C) 1998 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emission of europium(II) and europium(III) have been observed in SrMgF4 : xEu, yTb phosphors which are synthesized in Ar or Ar/H-2 flow. The valence state of Eu is influenced by terbium. It is notable that the intensities of the ESR peaks corresponding to EU(2+) are regularly changed when terbium ion is incorporated. The typical Tb3d XPS spectrum belonging to Tb4+ is also found when Eu is codoped. This phenomena can be explained by electron transfer mechanism Eu3+ + Tb3+-->EU(2+) + Tb4+. And its equilibrium constant is studied by ESR technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emission of europium(II) and europium(III) have been observed in SrMgF4 xEu, yTb phosphors winch are synthesized in Ar flow. The valence state of En is influenced by terbium, It is noted that the intensities of the ESR peaks corresponding to Eu2+ are increased when terbium ion is codopech this can be explained by electron transfer mechanism which is Eu3++Tb3+-->Eu2++Tb4+. And its equilibrium constant is calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effects of some factors on the performance of our Kalman filter in discrimination of closely spaced overlapping signals were investigated. The resolution power of the filter for overlapping lines can be strengthened by reduction of the step size in scans. The minimum peak separation of two lines which the Kalman filter can effectively handle generally equals two to three times the step size in scans. Significant difference between the profiles of the analysis and interfering lines and multiple lines from matrix in the spectral window of the analysis line are very helpful for the Kalman filter to discern closely spaced analysis and interfering signals correctly, which allow the filter well to resolve the line pair with very small peak distance or even the entirely coincident lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). Using scanning spectrometers commercially available today, a large relative error, DELTA(A) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. The emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. A quantitative relation between DELTA(A) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of Gaussian line profiles. The agreement between calculated and experimental DELTA(A) is also illustrated. The DELTA(A) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where DELTA(A) decreases with an increase in the ratio. Compared with dlambda, the effect of deltalambda is generally less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various borates, vanadates, niobates, antimonates, titanates, zirconates and CaS doped with Dy3+ were prepared. Factors which have an effect on the yellow-to-blue intensity ratio (Y/B) of Dy3+ emission are reported. Y/B increases with decreasing Z/r or electronegativity of the next-neighbour element M in the complex oxides Dy-O-M. The greater the degree of covalency between Dy3+ and O2-, the greater Y/B is. When Dy3+ is located at a site with an inverse centre and high symmetry, Dy3+ displays no luminescence. It seems that Y/B of Dy3+ located at a site deviated from an inverse centre is greater than that of Dy3+ located at a site without an inverse centre. Y/B does not vary much with the variation in concentration of Dy3+ when Dy3+ is substituted for an element with the same valency, but it does depend on the concentration of Dy3+ when Dy3+ is substituted for an element with a different valency in the matrix, because defects are formed in this case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the evaluation of the relative error (DELTA(A)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (MCA) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. In the theoretical part, a quantitative relation of DELTA(A) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of Gaussian line profiles. The measurements of eleven samples covering various typical line interferences showed that the calculated DELTA(A) generally agrees well with the experimental one. An expression of the true detection limit associated with MCA techniques was thus formulated. With MCA techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. Therefore. a given positioning error results in a larger DELTA(A) and hence a higher true detection limit in the case of MCA techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. In the light of the effect of wavelength positioning errors, MCA techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.