419 resultados para VOLTAMMETRY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrooxidation behavior of bilirubin (BR), biliverdin (BV), purpurin (Pu), and choletelin (Ch in dimethylformamide (DMF) have been investigated bv voltammetry, in situ electron spin resonance (ESR) thin-layer spectroelectrochemistry and especially i

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The compound K-1.64[Pt(C2O4)(2)] was electrochemically synthesized on a glassy carbon electrode using both single-potential step and cyclic voltammetry techniques; voltammetric behaviour of the working electrode was changed dramatically with deposition of

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrochemical catalytic reactions of tetraphenylporphinatocobalt were studied in DMF and EtCl2 solutions in the presence of 1,2-dibromoethane and 1, 2-dichloroethane utilizing cyclic voltammetry, thin-layer electrochemistry, in situ UV-visible spectroel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the presence of OH- anions, electrochemical redox reactions of cobalt tetraphenylporphyrin (TPP)Co were investigated in EtCl2 solution by thin-layer cyclic voltammetry and spectroelectrochemistry. In the pressence of OH-, OH- was axially coordinated to

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quinine derivatives, quinine hydrochloride and 8-hydroxyquinoline, transfer across the water/nitrobenzene interface was studied by cyclic voltammetry. The effect of solution acidity on the transfer behaviour was observed. Transfer mechanism was discussed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The transfer behavior of the heteropoly anion [H3PW11O39]4- and the isopoly anion [H2W12O39]4- across the water/nitrobenzene interface was investigated by cyclic voltammetry and chronopotentiometry with linear current scanning. The transfer processes were

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new type of macro-micro-macro triple electrode has been fabricated, the steady-state currents of solution redox species have been observed at an ultramicroband electrode by linear potential scan voltammetry, and generation/collection experiments have al

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of thin-layer resistance in cyclic voltammetry was studied in detail. Under the experimental conditions, a linear relationship between the peak-peak potential difference and the product of the peak current and the resistance was obtained and

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Langmuir-Blodgett (LB) monolayers of hexadecyl trimethyl ammonium bromide (HTAB) were deposited onto a carbon steel surface to investigate the inhibition of corrosion by measurement of the polarization resistance and cyclic voltammetry. The corrosion proc

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An investigation of electrode oxidation processes of (tetra-phenylporphinato) manganese (III) Perchlorate, (TPS)Mn(III)ClO4, was carried out during the titration of chloride anions by conventional cyclic voltammetry, thin-layer cyclic voltammetry and spectroelectrochemistry. It was demonstrated that in the presence of one equivalent amount of Cl-, the first one electron oxidation reaction corresponds to the Mn(III)I cation radical oxidation, and the second one electron oxidation corresponds to the cation radical/dication generation followed by an iso-porphyrin formation reaction, however in the presence of two equivalent amount of Cl-, the first one electron oxidation of Mn(III) gives Mn(IV) porphyrin and the second one electron oxidation generates cation radicals of Mn(IV) followed by an iso-porphyrin formation reactions. Mechanisms of these redox processes are postulated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The anodic oxidation kinetics of hydrazine on glassy carbon electrodes in acetonitrile were examined by cyclic voltammetry, a rotating ring-disc electrode technique and chronoamperometry. The experimental results of the rotating ring-disc electrode prove that hydrazine is oxidized to HN=NH, which cannot be oxidized further in acetonitrile. Hydrazine molecules are adsorbed on the electrode surface. One-third of the adsorbed hydrazine molecules are oxidized to HN=NH and the other two thirds act as proton acceptors. A possible mechanism of hydrazine oxidation is proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel type of electrochemical detector based on a polyaniline-dispersed mercury-coated glassy carbon chemically modified electrode was investigated for the detection of monochloramine and dichloramine. A polyaniline dispersed-mercury modified electrode, which was prepared by coating polyaniline on a thin mercury film electrode using fast-sweep voltammetry, was developed. The selectivity could be altered using various counter ions incorporated into the polymer. The results indicated that the use of a conducting polymer-based electrochemical sensor for the selective determination of chloramine is a feasible approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel device of multiple cylinder microelectrodes coupled with a parallel planar electrode was proposed. The feedback diffusion current at this device was studied using bilinear transformation of coordinates in the diffusion space, where lines of mass flux and equiconcentration are represented by orthogonal circular functions. The derived expression for the steady-state current shows that as the gap between cylindrical microelectrodes and planar electrode diminishes, greatly enhanced currents can be obtained with high signal-to-noise ratio. Other important geometrical parameters such as distance between adjacent microcylinders, cylinder radius, and number of microcylinders were also discussed in detail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the electrochemical behavior of vitamin B-12, ie cyanocobalamin (abbr. VB12) in a weak acidic aqueous solution and adsorbed on glassy carbon (GC) surface (abbr. VB12(ad)/GC) in different pH buffer solutions have been described by using cyclic voltammetry (cv). It is found that VB12 and VB12(ad)/GC exhibit catalytic activity for the electroreduction of O2 according to two reduction peaks at -0.50 and -1.00 V vs. sce; but their electrocatalytic activity is very unstable. Based on the method of hydrodynamic amperometry [B. Miller and S. Bruckenstein, J. electrochem. Soc. 117, 1033 (1970)], some kinetic parameters for the electrocatalytic reduction of O2 by VB12(ad)/GC have been determined rapidly by using a linear rotation-scan method [Rongzhong Jiang and Shaojun Dong, Electrochim. Acta 35, 1451 (1990)]. These kinetic parameters indicate that the reduction of O2 on VB12(ad)/GC gives water predominantly in both potential ranges which correspond to those two reduction peaks. Possible reaction mechanisms have been suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multi-cylinder microelectrode coupled with a conventional glassy carbon disc electrode (MCM/GC) was prepared and characterized using cyclic voltammetry and chronoamperometry. It was demonstrated that in the same way as one observed a steady-state current at closely spaced microelectrodes when redox recycling takes place, the same effect can be obtained with the MCM/GC device. The experimental results obtained with K3Fe(CN)6 solutions were compared with a previously developed theory. Further, it was demonstrated that with a carbon fibre MCM/GC device, the voltammetric behaviour of dopamine is greatly improved by virtue of redox recycling, hence giving high sensitivity. The steady-state collection current was linearly related to dopamine concentration in the range 1 X 10(-4) to 5 x 10(-7) Mol l-1, and the detection limit was 2 x 10(-7) mol l-1. The influence of coexisting ascorbic acid was also investigated. This device was applied successfully in the determination of dopamine hydrochloride in pharmaceutical preparations.