370 resultados para Electrochemical experiments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical identification of the urea denaturation of horse heart cytochrome c in bulk solution at the 4,4'-dithiodipyridine-modified gold electrode is reported. The results are similar to the three-step transitions of equilibrium studies (Myer et al., Biochemistry, 19 (1980) 199) of urea denaturation of cytochrome c in bulk solution. This method permits a clear resolution of which of the three steps of urea denaturation is electrochemically related. In addition, by analysing the effects of urea on the structural forms of cytochrome c and on the solution properties, as well as the cyclic voltammetric responses of the protein, the individual forms of the urea denaturation of cytochrome c can be understood. The results reflect the superposition of protein denaturation on the electrode surface and in solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behaviour of TCNQ modified S-BLM has been investigated through capacitor measurement and cyclic voltammetry (CV) which shows the surface wave behaviour of the TCNQ redox form. The voltammetry CV has shown different pairs peak at different scan rates and a possible explanation is provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transfer of chloride ions into a low resistance anion exchange membrane (AEM) was investigated by cyclic voltammetry (CV) and electrochemical impedance spectra. In all cases, concentration polarization of Cl- ions is exterior to the membrane. It controls the flux and produces the limiting currents: either steady state or transient (peak type) current. In CV experiments, when the size of the holes in the membrane was much smaller than the distance between membrane holes, the Cl- anion transfer showed steady state voltammetric behavior. Each hole in the membrane can be regarded as a microelectrode and the membrane was equivalent to a microelectrode array in this condition. When the hole in the membrane was large or the distance between membrane holes was small, the CV curve of the Cl- anion transfer across the membrane showed a peak shape, which was attributed to linear diffusion. In AC impedance measurement, the impedance spectrum of the membrane system was composed of two semicircles at low DC bias, corresponding to the bulk characteristics of the membrane and the kinetic process of ion transfer, respectively. The bulk membrane resistance increases with increasing DC bias and only one semicircle was observed at higher DC bias. The parameters related to kinetic and membrane properties were discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In situ electrochemical scanning tunneling microscopy (ECSTM) has been employed to follow the renewal process of a graphite electrode accompanied by flavin adenine dinucleotide (FAD) electrochemical reaction which involves adsorption of the reduced form (FADH(2)) and desorption of the oxidized form (FAD). The renewal process initiates from steps or kinks on the electrode surface, which provide high active sites for adsorption. This renewal depends on the working electrode potential, especially in the range near the FAD redox potential. Our experiment suggests that delamination of the graphite surface is caused by interaction between the substrate and adsorbed molecules. A simple model is proposed to explain this phenomenon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The voltammetric behavior of the titled compound (denoted as Nd (SiMo7W4)(2)(13-)) in aqueous solution had been studied. An unusual pH response was discussed. The adsorption of the anion on the dropping mercury electrode and a self-inhibition influence of the adsorbed anions on the redox process of those anions dissolved in solution were found. The electrocatalytic effects of the anion on the bromate reduction were investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behavior of the title compound (denoted Nd(SiMo7W4)(2)(13-)) in aqueous solution has been studied using cyclic voltammetry, sampled d.c. voltammetry, differential pulse voltammetry and bulk electrolysis with coulometry, The stable pH range of Nd(SiMo7W4)(2)(13-) is determined with UV-visible spectra. In the potential range between 0.70 and -0.45 V vs. SCE, the anion in pH 3.8 aqueous solution undergoes one-, one-, two- and two-electron steps of four redox processes attributed to electron addition and removal from the molybdate-oxo framework. The adsorption of the anion on the dropping mercury electrode and a self-inhibition influence of the adsorbed anions on the redox process of those anions dissolved in solution are found. The unusual dependence of the formal potentials on pH is explained with the competition of the protonation and ion-pair formation due to the high negative charge of Nd(SiMo7W4)(2)(13-) and its reduced forms. The electrocatalytic effects of the anion on the bromate are investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact non-stoichiometric molybdenum (VI, V) oxide of blue film was grown on carbon fiber (CF) microelectrode surface be cycling the potential between + 0.2V and - 0.70V in a freshly prepared Na2MoO4 solution containing 5 x 10(-3) mol/L H2SO4. The quantity-of the oxide is controlled by the charge passing the electrode. The electrochemical pretreatment of CF microelectrode not only mises the deposition velocity of molybdenum oxide on CF surface, but also improves greatly the cyclic voltammetric behavior of the molybdenum oxide film prior to the electrodeposition. The cathodic processes are believed to yield the hydrogen molybdenum oxide bronzes HxMoO3(0 < x < 2), or substoichiometric lower molybdenum oxides with the formula MoO3-y(0 < y < 1). The anodic response results from the reversible oxidation of molybdenum bronze/Mo(V) centers [or perhaps Mo(IV) in more reduced coatings], to Mo(VI). Further information was gained about the chemical composition and valent state of Mo from XPS and SEM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

4-Aminophenol (4-AP), paracetamol (PRCT), norepinephrine (NE), and dopamine (DA) (all somewhat hydrophobic compounds) were HPLC electrochemically detected while the signals from uric acid (UA) and ascorbic acid (AA) (both hydrophilic compounds at the pH studied) were minimized, taking advantage of the permselectivity of the self-assembled n-alkanethiol monolayer (C-10-SAM)-modified Au electrodes based on solute polarity, The effects of various factors, such as the chain length of the n-alkanethiol modifier, modifying time, and pH value, on the permeability of C-10-SAM coatings were examined, The calibration curves, linear response ranges, detection limits, and reproducibilities of the EC detector for 4-AP, PRCT, NE, and DA were obtained, The result shows that the EC detector can be applied in the chromatographic detection of 4-AP, PRCT, NE, and DA in urine, effectively removing the influence of UA and AA in high concentrations existing in biological samples. As a result, a great improvement in the selectivity of EC detectors has been achieved by using Au electrodes coated with neutral n-alkanethiol monolayer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An activated intermediate formed from H2O2 and cytochrome C is identified by direct electrochemical measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eastman-AQ 55D was coated onto a carbon fiber microelectrode surface, and the resulting modified electrodes exhibited high stability. Substantial improvement in the stability was observed as a result of good adhesion and the strong binding of large hydrophobic cations of Eastman AQ 55D. The electrode reaction of meldola blue bound in the polymer film showed a reversible, one-electron transfer process. The effects of solution pH and influence of supporting electrolyte on the modified carbon fiber microelectrode are discussed. The diffusion coefficient of meldola blue in the AQ polymer film determined by chronoamperometry is 2.3 x 10(-18) cm(2) s(-1), and the heterogeneous rate constant of meldola blue at the AQ polymer film/electrode determined by normal pulse voltammetry is 3.97 x 10(-3) cms(-1).