413 resultados para Atomic spectra.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray photoelectron spectra of the bioinorganic complexes of Na and La with N-acetylalanine and N-acetylvaline have been measured. It has been found that the spectra of the O 1s core level in the complexes of Na with these amino acids are very different from those in the complexes of La with the same amino acids. The results indicate that in the complexes of La with N-acetylalanine and N-acetylvaline, both the oxygen atoms from the carboxyl group and the oxygen atoms from the carbonyl group of the amino acids will directly coordinate to the La ion, whereas only the oxygen atoms from the carboxyl group of the amino acids can directly coordinate to the Na ion in the complexes of Na with N-acetylalanine and N-acetylvaline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effects of some factors on the performance of our Kalman filter in discrimination of closely spaced overlapping signals were investigated. The resolution power of the filter for overlapping lines can be strengthened by reduction of the step size in scans. The minimum peak separation of two lines which the Kalman filter can effectively handle generally equals two to three times the step size in scans. Significant difference between the profiles of the analysis and interfering lines and multiple lines from matrix in the spectral window of the analysis line are very helpful for the Kalman filter to discern closely spaced analysis and interfering signals correctly, which allow the filter well to resolve the line pair with very small peak distance or even the entirely coincident lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). Using scanning spectrometers commercially available today, a large relative error, DELTA(A) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. The emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. A quantitative relation between DELTA(A) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of Gaussian line profiles. The agreement between calculated and experimental DELTA(A) is also illustrated. The DELTA(A) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where DELTA(A) decreases with an increase in the ratio. Compared with dlambda, the effect of deltalambda is generally less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the evaluation of the relative error (DELTA(A)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (MCA) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. In the theoretical part, a quantitative relation of DELTA(A) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of Gaussian line profiles. The measurements of eleven samples covering various typical line interferences showed that the calculated DELTA(A) generally agrees well with the experimental one. An expression of the true detection limit associated with MCA techniques was thus formulated. With MCA techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. Therefore. a given positioning error results in a larger DELTA(A) and hence a higher true detection limit in the case of MCA techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. In the light of the effect of wavelength positioning errors, MCA techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray photoelectron spectra of some bioinorganic complexes of La, Pr, Nd, Sm, and Gd with N-acetylvaline have-been measured. The complex formation does not give any detectable influence on the binding energy of the N 1s peak in the amino group, but has some appreciable effect on the binding energy of the C 1s peak and the O 1s peak in the carboxyl and carbonyl group of the biological ligand. The spin-orbit splitting between the 3d5/2 and 3d3/2 core level of the rare earth ion in these bioinorganic complexes also becomes slightly larger than that of the free rare earth atom due to the effect of the crystal field from the biological ligands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Kalman filter was developed for resolving overlapping lines in inductively coupled plasma atomic emission spectrometry (ICP-AES) and evaluated experimentally with the determination of La in the presence of Ho, and Cu in the presence of Pr. The whiteness of the innovation sequence for an optimal filter was explored to be the criterion for the correction of the wavelength positioning errors which may occur in spectral scans. Under the conditions of the medium-resolution spectrometer and 1.5 pm step size in scans, the filter effectively resolved the Cu/Pr line pair having a small peak separation of 4.8 pm. For the La/Ho line pair with a peak distance of 9.8 pm, an unbiased estimate for La concentration was still obtained even when the signal-to-background ratio was down to 0.048. Favourable detection limits for real samples were achieved. Unstructured backgrounds were modeled theoretically and all spectral scans therefore did not require the correction for solvent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the evaluation of the reliability of the analytical results obtained by Kalman filtering. Two criteria for evaluation were compared: one is based on the autocorrelation analysis of the innovation sequence, the so-called NAC criterion; the other is the innovations number, which actually is the autocorrelation coefficient of the innovation sequence at the initial wavelength. Both criteria allow compensation for the wavelength positioning errors in spectral scans, but there exists a difference in the way they work. The NAC criterion can provide information about the reliability of an individual result, which is very useful for the indication of unmodelled emissions, while the innovations number should be incorporated with the normalization of the innovations or seek the help of the sequence itself for the same purpose. The major limitation of the NAC criterion is that it does not allow the theoretical modelling of continuous backgrounds, which, however, is convenient in practical analysis and can be taken with the innovations number criterion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Langmuir-Blodgett (LB) films of (p-carboxyphenoxy)-tri(2,4-di-tert-pentyl phenoxy)phthalocyanine copper(II) (asyCuPc) are prepared; the associated forms of the compound in chloroform solution and the particular orientation of asyCuPc molecular macrocycles in LB films is determined by polarized UV-VIS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

K7H6[Nd(GeMo11O39)2].18H2O was first synthesized and the crystal structure was determined. Crystal structure data are as follows: monolinic, space group P2(1)/n, a = 1.7095(4), b = 2.6895(3), c = 2.1214(5) nm, beta = 103.11 (2)-degrees, V = 9.4994(3) nm3, Z = 4, D(m) = 3.14g/cm3, D(c) = 3.05g/cm3, mu(MoK-alpha) = 43.7 cm-1. Experimental evidence and theoretical foundation of the method inferring the molecule structure of heteropoly compounds using their IR spectra were gaved by studying IR spectra properties of the complex with results of structural analysis. Electronic spectra prove that 4f-obital of Nd3+ take part in bonding in the complex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study of doubly charged ion mass spectra (2E spectra), the substituents effect and the target gas pressure deppendence of biphenyl derivitives was presented in this work. The decomposition of doubly charged ion formed in the ion source is dominant by the losses of H, C2H2, C2H4 and HR(R represents substituent). [C12H8]2+, [C12H6]2+ and [C10H6]2+ among others are the most stable product ions. The substituents effect is Various in different decomposition reactions, and in some cases it can not be predicted by Hammett equition. While the TIC of 2E spectra was markedly influenced by the target gas pressure, but the fragmentation pattern of the 2E spectra is independent of it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The title complex has beep synthesized by the reaction of CaCl2, with trimethyl phosphate. Its Infrared spectra from 4000 to 100 cm(-1) measured. The assignment of acme absorption bands was discussed. It is found that the stretching vibrations of bridge groups O-P-O are divided into two groups according to their bond length. The crystal structure of the complex boa been determined from single crystal K-ray diffraction data. The crystals belong to monoclinic system, space group P2(1)/c with cell parameteras, a = 1,0704(4), b = 0.5093(2), c = 1.9737(6)nm, beta = 96.23(3)degrees, V = 1.0696(6)nm(2), Z = 4, final R = 0.044. Copper ion is coordinated to five Rimester oxygen atoms to form a distorted square pyramid. The adjacent copper ions are connected by symmetric and non-symmetric bridge groups of O-P-O, forming an infinite one-dimensional chain coordination polymer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal stability and the solid solid phase transitions in Ills compounds with n = 7-12 have been studied by DSC and TG methods. Comparision with CnZn compounds want made. The nature of three phases of CnCu has been discussed in terms of infrared spectroscopy and the assignment of the phase transitions has been given. The thermal stability of CnCu is lower than that of CnZn and presents an obvious odd even effect. All of these compounds exhibit two solid solid phase transitions in the temperature range of 248-337 K. The peak tempe nature of phase transitions changes regularly. The peak temperature or the main phase transition increases with the chain length. The total transition enthalpies and entropies increase with increasing chain length. When n <= 9, the high temperature phase exists in a partial disorder state. When n >= 10, the high temperature phase exists in a conformational disorder state. The main phase transition and the phase transition at 307.7 K of CnCu may mainly are from the change of the packing structure and the change of the partial conformational order-disorder of alkyl chain, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The low-frequency Raman spectrum of n-decylammonium chloride was measured as a function of temperature in the temperature range from 290 to 340K, and the longitudinal acoustical mode vibration band was assigned. The results showed that there are two phase transitions at 313K and 321K, respectively. The phase transition at 313K is mainly induced by change of hydrocarbon chain conformations, while that at 321K is mainly induced by change of order degree of molecular packing. The results suggest low-frequency Raman spectroscopy is a useful probe of structural phase transition for long-chain compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mass spectral behaviour of 15 new type of organic phosphorus compounds with a considerable insecticidal activity, 1, 3,2-oxazaphospholidine 2-sulfides derivatives, under 70 eV electron impact has been studied by means of high and low resolution mass spectrometry as well as by B/E linked scan and MIKES/CID analysis. Discussion is focused into the isomerization between oxygen and sulphur in molecules and some rearrangement reactions.