439 resultados para super-heavy nuclei
Resumo:
The main ion beams acceleration facilities and research fields of the Institute of Modern Physics (IMP) are briefly introduced. Some of the experimental instruments, typical works and the obtained results on the materials research with swift heavy ions at the IMP-accelerators are presented.
Resumo:
Human hepatoma and normal liver cells were irradiated with C-12(6+), ion beams (LET= 96.05 keV/mu m) and gamma-rays at Heavy Ion Research Facility in Lanzhou (HIRFL). The chromatid breaks and break types were detected using the premature chromosome condensation technique. Our experimental results showed that chromatid breaks seem to have a good relation with C-12(6+) absorbed dose and C-12(6+) are more effective to induce chromatid breaks as compared to they-rays. For C-12(6+) ion irradiation the major break was isochromatid break, while chromatid breaks were dominant for gamma-ray irradiation. We also observed that the Relative Biology Effectiveness (RBE) of C-12(6+) ion is about 2.5 times higher than that of gamma-rays.
Resumo:
The double neutron/proton ratio of nucleon emissions taken from two reaction systems using four isotopes of the same element, namely, the neutron/proton ratio in the neutron-rich system over that in the more symmetric system, has the advantage of reducing systematically the influence of the Coulomb force and the normally poor efficiencies of detecting low energy neutrons. The double ratio thus suffers less systematic errors. Within the IBUU04 transport model the double neutron/proton ratio is shown to have about the same sensitivity to the density dependence of nuclear symmetry energy as the single neutron/proton ratio in the neutron-rich system involved. The double neutron/proton ratio is therefore more useful for further constraining the symmetry energy of neutron-rich matter.
Resumo:
The heavy ion linac in Lanzhou is designed as a future injector for the Cooling Storage Ring (CSR). In order to keep the total machine within 40 meters, the IH (Interdigital H-type) structure is adopted for its higher acceleration gradient compared with the traditional DTL structure. The designed minimum charge over mass ratio is 1/6, the output energy is 16MeV/u and the beam current is 1A.mu A. The RFQ and the first DTL tank will work at 100MHz, and the other DTL tanks will work at the double frequency. The design criteria, main parameters and the detailed beam dynamic design are introduced in this paper.
Resumo:
The properties of the nuclei belonging to the newly observed nuclei starting from (288)115 have been studied with the generalized liquid drop model connected with WKB approximation. The calculated results have been compared with the results of the DDM3Y theory and the experimental data. The half lives of this new alpha decay chain have been well tested from the consistence of the macroscopic, microscopic and the experimental data.
Resumo:
Using a phenomenological asymmetric nuclear equation of state, we obtained pressure-density isotherms of the finite nucleus Sn-112 simulated in r-space and in p-space and constructed the nuclear fragments by using the coalescence model. After correlatively analysing the fragments, the signal of critical behavior has been found and critical exponents were also extracted.
Resumo:
The excitation functions of elastic scattering proton which were measured with inverse kinematics of elastic resonance scattering reactions in GANIL and MSU have been fitted by the multi-energy level R-matrix theory. The final result shows that the new energy levels order for nucleus N-11 should be 1/2(+), 1/2(-), 5/2(+), 3/2(+), 3/2(-), 5/2(+), 7/2(-), which is consistent with the experimental results of Be-11 (the mirror nucleus of N-11) and the theoretical calculation of N-11 with GCM theory.
Resumo:
An isospin degree of freedom is inserted into the momentum dependent interaction in the quantum molecular dynamics model to obtain an isospin dependent momentum interaction given in a form practically usable in isospin dependent quantum molecular dynamics model. We investigate the entrance channel effects for the role of isospin momentum dependent interaction on the isospin fractionation ratio and its dynamical mechanism in the intermediate energy heavy ion collisions. It is found that the isospin dependent momentum interaction induces a significant reduction of isospin fractionation ratio under all entrance channel conditions. However the strong dependence of isospin fractionation ratio on the symmetry potential is preserved after considering the isospin degree of freedom in the momentum dependent interaction.
Resumo:
With the commissioning of the Cooler Storage Ring at the Heavy Ion Research Facility in Lanzhou (HIRFL-CSR), a pilot experiment operating the CSRe in isochronous mode to test the power of HIRFL-CSR for measuring the mass of the short-lived nucleus was performed in December of 2007. The transition point gamma t of CSRe in isochronous mode is 1.395 which corresponds to the energy about 368 MeV/u for the ions with atomic number-to-charge ratio A/q = 2. The fragments with A/q = 2 of Ar-36 were injected into CSRe and their revolution frequencies were measured with a fast time pick-up detector with a thin foil in the circulating path of the ions. A mass resolution of better than 105 for m/Delta m was achieved.
Resumo:
To investigate effects of nitric oxide on cellular radio-sensitivity, three human glioma cell lines, i.e. A172, A172 transfected green fluorescence protein (EGFP) gene (EA172) and A172 transfected inducible nitric oxide synthesis (iNOS) gene (iA72), were irradiated by C-12(6+) ions to 0, 1 or My. Productions of nitric oxide and glutathione (GSH) in A172, EA172 and iA172 were determined by chemical methods, cell cycle was analyzed by flow cytometry at the 24th hour after irradiation, and survival fraction of the cells was measured by colorimetric MTT assay at the 5th day after irradiation. The results showed that the concentrations of nitric oxide and GSH in iA172 were significantly higher than in A172 and EA172; the G(2)/M stage arrest induced by the C-12(6+) ion irradiation was observed in A172 and EA172 but not in iA172 at the 24th hour after exposure; and the survival fraction of iA172 was higher than that of EA172 and iA172. Data suggest that the radio-sensitivity of the A172 was reduced after the iNOS gene transfection. The increase of GSH production and the change of cellular signals such as the cell cycle control induced by nitric oxide may be involved in this radio-resistance.
Resumo:
There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e mu A of O7+, 505 e mu A of Xe20+ 306 e mu A of Xe27+, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.
Resumo:
癌症是现代医学的难题,一直危害着人类的健康。放射治疗是癌症治疗的有效手段之一。由于重离子束在物理学和生物学性质上所具有的优势,它已成为放疗用的最佳射线。简述了重离子治癌的发展历程、现状以及特点,详细讨论了在医学物理和放射生物学研究领域值得关注的若干热点问题。
Resumo:
从采集的土壤样品中分离筛选出一株碱性蛋白酶产生菌G-41,经16S rRNA分子鉴定为芽孢杆菌属菌株。该菌株在发酵培养基中能产生较高产量的胞外碱性蛋白酶(1.7×104U/mL)。以G-41为出发菌株,对其进行重离子辐照诱变处理,获得突变株G-41-68,将该突变株再次经重离子诱变,从大量突变株中筛选出碱性蛋白酶高产菌株15Gy-54,其酶活力达到6.22×104U/mL。与出发菌株相比较,突变株G-41-68和15Gy-54的酶活力分别提高了1.58倍和2.65倍。对突变株15Gy-54的发酵条件进行了优化研究,结果表明,该菌株的碱性蛋白酶活力得到进一步提高,达到7.18×104U/mL,其最适发酵条件为:培养基(g/100mL)为胰蛋白胨1、酵母膏0.5、乳糖5、Na2HPO4·12H2O0.4、KH2PO40.03、Na2CO30.1、MgSO40.0481(4×10-3mol/L)、pH8.0,培养温度41℃,振荡培养时间42-48h。实验结果表明,重离子辐照诱变技术是一种非常有效的微生物诱变育种新技术。
Resumo:
Polypropylene (PP) microporous membranes were successfully prepared by swift heavy ion irradiation and track-etching. Polypropylene foils were irradiated with Au-197 ions of kinetic energy 11.4 MeV.u(-1) (total energy of 2245.8 MeV) and fluence 1x10(8) ions.cm(-2) at normal incidence. The damaged regions produced by the gold ions along the trajectories were etched in H2SO4 and K2Cr2O7 solutions leading to the formation of cylindrical pores in the membranes. The pore diameters of the PP microporous membranes increased from 380 to 1610 nm as the etching time increased from 5 to 30 min. The surface and cross-section morphologies of the porous membranes were characterized by scanning electron microscopy (SEM). The micropores in the membranes were found to be cylindrical in shape, homogeneous in distribution, and equal in size. Some mathematical relations of the porosity of the PP microporous membranes were established by analytic derivation. The microporous membranes were used in lithium-ion batteries to measure their properties as separators. The electrical conductivity of the porous membrane immersed in liquid electrolyte was found to be comparable to that of commercial separators by electrochemical impedance spectroscopy (EIS). The results showed that the porosity and electrical conductivity were dependent on the ion fluence and etching time. By adjusting these two factors, microporous membranes with good porosity and electrical conductivity were made that met the requirements for commercial use.