345 resultados para Energetic ions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multi-photon ionization process of the hydrogen-bond cluster of pyridine-methanol has been investigated using a conventional and reflectron time-of-flight mass spectrometer (RTOF-MS) at 355 and 266 nm laser wavelengths, respectively. The sequences of the protonated cluster ions (CH3OH)(n)H+ and (C5H5Nn)(CH3OH)(m)H+ (n = 1,2) were observed at both laser wavelengths, while the sequence of the cluster ions (CH3)OHn (H2O)H+ was observed only at 355 nm laser wavelength. The difference between the relative signal intensities of the protonated methanol cluster ions at different laser wavelengths is attributed to different photoionization mechanisms. Some nascent cluster ions in metastable states dissociated during free flight to the detector. The dissociation kinetics is also discussed. (C) 2000 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photoionization of methyl iodide beam seeded in argon and helium is studied by time-of-flight mass spectrometry using a 25 ns, 532 nm Nd-YAG laser with intensities in the range of 2 x 10(10)-2 x 10(11) W/cm(2). Multiply charged ions Of Iq+ (q = 2-3) and C2+ with tens of eV kinetic energies have been observed when laser interacts with the middle part of the pulsed molecular beam, whose peak profiles are independent on the laser polarization directions. Strong evidences show that these ions are coming from the Coulomb explosion of multiply charged CH3I clusters, and laser induced inverse bremsstrahlung absorption of caged electrons plays a key role in the formation of multiply charged ions. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for determining of heavy metal ions by field-amplified sample injection capillary electrophoresis with contactless conductivity detection. The effects of the 2-N-morpholinoethanesulfonic acid/histidine (MES/His) concentration in the sample matrix, the injection time and organic additives on the enrichment factor were studied. The results showed that MES/His with a low concentration in the sample matrix, an increase of the injection time and the addition of acetonitrile improved the enrichment factor. Four heavy metal ions (Zn2+, Co2+, Cu2+ and Ni2+) were dissolved in deionized water, separated in a 10 mM MES/His running buffer at pH 4.9 and detected by contactless conductivity detection. The detection sensitivity was enhanced by about three orders of magnitude with respect to the non-stacking injection mode. The limits of detection were in the range from 5 nM (Zn2+) to 30 nM (Cu2+). The method has been used to determine heavy metal ions in tap water.