307 resultados para Column liquid chromatography


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effects of direct sampling and three digestion methods were investigated on the determination of arsenic in Chang liver hepatocytes after ultrasonic disintegration were investigated. The results showed that the efficiency of microwave digestion and obturator digestion was better than cold digestion and direct sampling. The day precision (present as RSD) of microwave digestion and obturator digestion were 2.1% and 1.2% the inter-day precision were 1.2% and 2.0%, respectively. The spike recovery for the total As in the sample is 95.7% - 108.1%. The As detection limits with these four sample treatment methods (including direct sampling) were 0.74 - 0.93 mu g/L. In addition, arsenic speciation in Chang liver hepatocytes was also analyzed using the hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma-mass spectrometry. The experimental results indicated that dimethylarsinic acid (DMA) and an intermediate metabolite of DMA were found lit Chang liver hepatocytes besides inorganic arsenic (As(III) and As(V)).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Me optimal conditions were established for the extraction of paralytic shellfish poisoning toxins from gonad of Chlamys nobills using acetic acid and hydrochloric acid in the concentration range of 0.04-1.0 mol/L. A 10-g portion of gonad of Chlamys nobilis was extracted by boiling for 5 min with 1.0 mL acetic acid and hydrochloric acid in a 50-mL beaker. Meanwhile, a portion of gonad of Chlamys nobilis was extracted by sonication in the solution of 0.3 mol/L HAc + 0.2 mol/L HCl for a total period of 5-30 min. The raw extract was centrifuged at 3500 r/min for 5 min and the pH of supernatant was adjusted from 2.0 to 4.0 by 0.1 mol/L NaOH or 5 mol/L HCL After passing through a Millipore ultrafiltration membrane (10000 MW cut-off), ultrafiltrate was then analyzed by HPLC. The results showed that hydrochloric acid in the concentration range of 0.25-1.0 mol/L caused a significant decrease of N-sulfocarbarnoyl-11-hydroxysulfate toxin C1 (C1), C2 and gonyautoxin 5 (GTX5) and the concomitant increase of GTX2,3. However, the amount of the three unstable toxins did not show any change using the extraction with acetic acid. Under the same concentration of acetic acid (0.3 mol/L) and hydrochloric acid (0.2 mol/L), the amount of C1 in the ultrasonic extraction was obviously lower than the boiling one, while C2 showed slightly higher than the latter.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bacteria isolated from a highly toxic sample of gastropod Nassarius semiplicatus in Lianyungang, Jiangsu Province in July 2007, were studied to probe into the relationship between bacteria and toxicity of nassariid gastropod. The toxicity of the gastropod sample was 2 x 10(2) mouse unit (MU) Per gram Of tissue (wet weight). High concentration of tetrodotoxin (TTX) and its analogues (TTXs) were found in the digestive gland and muscle of the gastropod, using high performance liquid chromatography coupled with mass chromatography (LC-MS). Bacterial strains isolated from the digestive gland were cultured and screened for TTX with a competitive ELISA method. Tetrodotoxin was detected in a proportion of bacterial strains, but the toxin content was low. Partial 16S ribosomal DNA (rDNA) of the TTX-producing strains was then sequenced and compared with those published in the GenBank to tentatively identify the toxic strains. It was found that most of the toxic strains were closely affiliated with genus Vibrio, and the others were related to genus Shewanella, Marinomonas, Tenacibaculum and Aeromonas. These findings suggest that tetrodotoxin-producing bacteria might play an important role in tetrodotoxin accumulation/production in N. semiplicatus. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two strains H-2-410 and H-2-419 were obtained from the chemically mutated survivors of wild Haematococcus pluvialis 2 by using ethyl methanesulphonate (EMS). Strains H2-410 and H2-419 showed a fast cell growth with 13% and 20% increase in biomass compared to wild type, respectively. Then H-2-419-4, a fast cell growth and high astaxanthin accumulation strain, was obtained by exposing the strain H2-419 to ultraviolet radiation (UV) further. The total biomass, the astaxanthin content per cell, astaxanthin production of H-2-4194 showed 68%, 28%, and 120% increase compared to wild H. pluvialis 2, respectively. HPLC (High Performance Liquid Chromatography) data showed also an obvious proportional variation of different carotenoid compositions in the extracts of H2-4194 and the wild type, although no peak of carotenoids appeared or disappeared. Therefore, the main compositions in strain H-2-419-4, like its wild one, were free of astaxanthin, monoester, and diester of astaxanthin. The asexual reproduction in survivors after exposed to UV was not synchronous, and different from the normal synchronous asexual reproduction as the mother cells were motile instead of non-motile. Interestingly, some survivors from UV irradiation produced many mini-spores (or gamete?), the spores moved away from the mother cell gradually 4 or 5 days later. This is quite similar to sexual reproduction described by Elliot in 1934. However, whether this was sexual reproduction remains questionable, as no mating process has been observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A rapid and sensitive liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS) assay for the determination of five pharmacologically active compounds (PAC) extracted from the traditional Chinese medicine, Rhodiola , namely salidroside, tyrosol, rhodionin, gallic acid, and ethyl gallate has been developed. In this method, PAC could be baseline separated and detected with DAD at 275 nm. The validation of the method, including sensitivity, linearity, repeatability, and recovery, was examined. The linear calibration curves were acquired with correlation coefficient >0.999 and the limits of detection LOD (at a signal-to-noise ratio=3:1) were between 0.058 and 1.500 mu mol/L. It was found, that the amounts of PAC varied with different species of Rhodiola . The established method is rapid and reproducible for the separation of five natural pharmacologically active compounds from extracts of Rhodiola with satisfactory results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pharmacologically active xanthone compounds isolated from Swertia przewalskii pissjauk were well separated by capillary electrophoresis (CE) within 5 min, using a running buffer of 25 mM disodium tetraborate at pH 9.0. Quantitative determination was shown to be possible because regression equations revealed a linear relationship between the peak area of each constituent and its concentration, with correlation coefficients of 0.9972-0.9994. The relative standard deviations were between 0.44%-0.73% for migration times and 2.52%-4.28% for peak areas. The dissociation constant of 1,7-O-beta-D-glucopyranosyl-8-hydroxy-3,7-dimethoxyxanthone, 1,8-dihydroxy-3, 7-dimethoxy-xanthone and 1,7-dihydroxy-3,8-dimethoxyxanthone were also measured by the CE method, giving a value of 9.04, 8.94, and 8.59, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Urinary 8-hydroxydeoxyguanosine (80HdG) has been considered as an excellent marker of individuals at high risk of developing cancer. Until now, urinary 80HdG has largely been measured by high-performance liquid chromatography with electrochemical detection. A new method for the analysis of urinary 80HdG by high-performance capillary electrophoresis has been developed and optimized in our laboratory. A single step solid-phase extraction procedure was optimized and used for extracting 80HdG from human urine. Separations were performed in an uncoated silica capillary (50 cm x 50 tm i.d.) using a P/ACE MDQ system with UV detection. The separation of 80HdG from interfering urinary matrix components is optimized with regard to pH, applied voltage, pressure injection time and concentration of SDS in running buffer. The detection limit of this method is 0.4 mug/ml, the linear range is 0.8-500 mug/ml, the correlation coefficients levels is better than 0.999. The developed method is simple, fast and good reproducibility, furthermore, it requires a very small injection volumes and low costs of analysis, which makes it possible to provide a new noninvasive assay for an indirect measurement of oxidative DNA damage.