35 resultados para chat reference
Resumo:
Photosynthetic responses to irradiance and temperature of "leaves" and receptacles were compared in February ( vegetative stage) and May ( reproductive stage) in the seaweed, Hizikia fusiforme ( Harvey) Okamura (Sargassaceae, Phaeophyta) from Nanao Island, Shantou, China. Irradiance-saturated photosynthesis (P-max) was significantly higher in receptacles than in "leaves" on a fresh weight basis, and that of "leaves" was greater in May than in February at ambient seawater temperatures. The optimum temperature for P-max was 30 degrees C for both "leaves" and receptacles, being 5 - 10 degrees C higher than the ambient seawater temperature. The apparent photosynthetic efficiencies were greater in receptacles than in "leaves" within the tested temperature range of 10 - 40 degrees C. The irradiance for saturating photosynthesis for both "leaves" and receptacles was temperature-dependent, with the highest values ( about 200 mu mol photons m(-2) s(-1)) at 30 degrees C.
Resumo:
Two species of aspidogastreans, namely Aspidogaster ijimai and A. conchicola, were studied by scanning electron microscopy. In nine lakes and an old river course, the Tian'ezhou oxbow, investigated in the flood plain of the Yangtze River, A. ijimai was obtained from the common carp (Cyprinus carpio) in three lakes, and A. conchicola from the black carp Mylopharyngodon piceus in three lakes and the oxbow. In none of the localities, however, were the two species found together. It is suggested that A. ijimai may be considered as a specialist parasite for the common carp, at least in the flood-plain lakes of the Yangtze River. The two parasites were similar in many aspects of their morphology. Their bodies can both be separated into a dorsal part and a ventral disc, with the body surface of the dorsal part elevated by transverse folds, and the disc subdivided into alveoli by transverse and longitudinal septa, although the number of alveoli was different in the two species. The depression on the ventral surface of the neck region was prominent for both species, and their ventral disc was covered densely with non-ciliated bulbous papillae. The position of mouth, osmo-regulatory pore and marginal organ was also similar for A. ijimai and A. conchicola. However, microridges in the trough of the folds in the neck region and numerous small pits on the upper part of the septa were found exclusively in A. ijimai, but uniciliated sensory papillae in A. conchicola.
Resumo:
Goal, Scope and Background. In some cases, soil, water and food are heavily polluted by heavy metals in China. To use plants to remediate heavy metal pollution would be an effective technique in pollution control. The accumulation of heavy metals in plants and the role of plants in removing pollutants should be understood in order to implement phytoremediation, which makes use of plants to extract, transfer and stabilize heavy metals from soil and water. Methods. The information has been compiled from Chinese publications stemming mostly from the last decade, to show the research results on heavy metals in plants and the role of plants in controlling heavy metal pollution, and to provide a general outlook of phytoremediation in China. Related references from scientific journals and university journals are searched and summarized in sections concerning the accumulation of heavy metals in plants, plants for heavy metal purification and phytoremediation techniques. Results and Discussion. Plants can take up heavy metals by their roots, or even via their stems and leaves, and accumulate them in their organs. Plants take up elements selectively. Accumulation and distribution of heavy metals in the plant depends on the plant species, element species, chemical and bioavailiability, redox, pH, cation exchange capacity, dissolved oxygen, temperature and secretion of roots. Plants are employed in the decontamination of heavy metals from polluted water and have demonstrated high performances in treating mineral tailing water and industrial effluents. The purification capacity of heavy metals by plants are affected by several factors, such as the concentration of the heavy metals, species of elements, plant species, exposure duration, temperature and pH. Conclusions. Phytoremediation, which makes use of vegetation to remove, detoxify, or stabilize persistent pollutants, is a green and environmentally-friendly tool for cleaning polluted soil and water. The advantage of high biomass productive and easy disposal makes plants most useful to remediate heavy metals on site. Recommendations and Outlook. Based on knowledge of the heavy metal accumulation in plants, it is possible to select those species of crops and pasturage herbs, which accumulate fewer heavy metals, for food cultivation and fodder for animals; and to select those hyperaccumulation species for extracting heavy metals from soil and water. Studies on the mechanisms and application of hyperaccumulation are necessary in China for developing phytoremediation.
Resumo:
Concentration of trace elements measured by dry weight basis has become more commonly used in recent studies on cetaceans than wet weight basis, which was used more in earlier studies. Because few authors present moisture content data in their papers, it is difficult to compare the concentrations of trace elements between various studies. Therefore, we felt that it would be useful if a reference conversion factor (CF) for tissue types could be found to convert between wet weight and dry weight data on trace element concentrations. We determined the moisture contents of 14 tissues of Dall's porpoise (Phocoenoides dalli), and then, calculated the CF values for those tissues. Because the moisture content of each tissue differs from other tissues, it is necessary to use a specific CIF for each tissue rather than a general CF for several tissues. We have also found that CIF values for Dall's porpoise tissues are similar to the same tissues in other cetaceans. Therefore CF values from Dall's porpoise can be reliably used to convert between wet and dry weight concentrations for other cetacean tissues as reference data. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
A total of six stations in the Han River system were selected for establishing polyurethane foam units (PFUs) to collect protozoans, including phytomastigophorans, zoomastigophorans, amoebas and ciliates, in July 1993. In the bioassessment of microbial communities using the PFUs, the number of species decreased as pollution intensity increased. The diversity index values calculated at the main stations generally agreed with the pollution status of the stations. Anyang-Chon (Chon means stream) showed the lowest diversity value (1.89), and all stations, except Masok and Anyang-Chon, showed diversity index values ranging from 3.15 to 3.93. The highest heterotrophic index (HI) value was detected in Anyang-Chon followed by Masok-Chon. The number of species at the main stations reached a maximum on day 11 of being exposed to PFUs. The results of S-eq, G and T-90% all suggest that bioassessments using the PFU system were well matched with pollution status of the water. All microbial variables were significantly correlated with comprehensive chemical pollution indices, P-a and P-b, with correlation coefficients ranging from r=0.87 to r=0.96.
Resumo:
An adaptive phase-locked loop (PLL) frequency synthesizer architecture for reducing reference sidebands at the output of the frequency synthesizer is described. The architecture combines two tuning loops: one is the main loop for locking the PLL frequency synthesizer and operating all the time, the other one is auxiliary loop for reducing reference sidebands and operating only when the main loop is closely locked. A 1.8V 1GHz fully integrated CMOS dual-loop frequency synthesizer is designed in a 0.18um CMOS process. The suppression of the reference sidebands of the proposed frequency synthesizer is 13.8dB more than that of the general frequency synthesizer.
Resumo:
A method for the analysis of mussel standard reference material by inductively coupled plasma atomic emission spectrometry( ICP-AES) and inductively coupled plasma mass spectrometry(ICP-MS) was developed. K, Na, Ca, Mg, P, Al, Fe, Zn, Mn and Sr were determined by ICP-AES and As, B, Cd, Co, Cr, Cu, Ga, Ge, Mn, Mo, Ni, Pb, Se, Sr, U and V by ICP-MS, The interference coefficients at the Mn-55, Se-78, Cu-63, Co-59, Ni-58, Ni-60, As-75, Se-77, V-51, Cr-53 and Cr-52 originating from polyatomic ion of the matrix elements (KO)-K-39-O-16, K-39(2), (ArNa)-Ar-40-Na-23, (CaO)-Ca-43-O-16, (CaO)-Ca-42-O-16, (CaO)-Ca-44-O-16, (PO2)-P-31-O-16, (ArCl)-Ar-40-Cl-35, (ArCl)-Ar-40-Cl-37, (ClO)-Cl-35-O-16, (ClO)-Cl-37-O-16 and (ArC)-Ar-40-C-12 were determined under the selected operation parameters. The major matrix elements, such as K, Na and Ca, result in the suppression of analytes signals. The apparent concentration at the significant biological element which was produced by the different digestion methods, (.) HNO3 + H2O2 (3 + 2), HNO3 + HClO4 (3 + 0.5) and HNO3 + H2SO4 (3 + 0.5),was determined. The sample digested by HNO3 + H2O2 did not give rise to interfere on the analyte, and the backgrounds of Se-77, Ga-69, Zn-67, As-75, V-51, Cr-53 and Cr-52 were increased by HNO3 + HClO4 digestion method, that affected the determination of these elements, especially the monoisotope As and V. Sample digested by HNO3 + H2SO4 increased the backgrounds at Cu-65, Zn-64 and Zn-67. Detection limits of ICP-AES are 0.001 similar to 0.75 mg/L and those of ICP-MS are 0.005 similar to 1.01 mu g/L. The relative standard derivations of ICP-AES and ICP-MS are 2.7% similar to 12.8%, 3.4% similar to 24.8%, respectively.
Resumo:
A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1.0 moll(-1) HCl with a pulse current density of 20 mA cm(-2), and the pulse wave parameters of t(a)/t(c) = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t(r)) to the working time (t(w)) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 moll(-1) KCl was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.