64 resultados para antigen-antibody


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monoclonal antibody technique was employed to detect the conformational change of calmodulin induced by metal ions. Bovine calmodulin was firstly modified by 2,4-dinitrofluorobenzene to improve its immunogenicity, then, the derived protein was saturated with trivalent europium ions and injected to Balb/c mice as antigen. After four times of immunization, a corresponding antibody was detected and its titer in serum was determined as 1 : 12 000. By fusing of the spleen cells with hybridoma cells, a europium induced conformation-specific anti-calmodulin monoclonal antibody cell strain named as 2C3 was produced successfully. The molecular recognition ability of antibody to apocalmodulin and holocalmodulin showed a significant difference, indicating that this antibody could be applied to the studies of different effects of metal ions on the conformational change of calmodulin and its interaction with target molecules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monoclonal antibody technique was employed to detect the conformational difference of CaM induced by metal ions. A trivalent europium ion induced conformation-specific anti-calmodulin monoclonal antibody was successfully prepared with europium-saturated calmodulin as antigen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rabies virus was used as the antigen to immunize laying chickens. Anti-rabies virus immunoglobulin Y(IgY) was isolated from yolks of the eggs laid by these chickens using a two-step salt precipitation and one-step gel filtration protocol. The purified IgY was reduced with dithiothreitol, and heavy chains (HC) and light chains (LC) were obtained. In addition, the purified IgY was digested with pepsin and the fragment with specific antigen binding properties (Fab) was produced. Using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS), the average molecular weights of IgY, HC, LC, and Fab were determined as 167 250, 65 105, 18 660, and 45,359 Da, respectively. IgY has two structural differences compared with mammalian IgGs. First, the molecular weight of the heavy chain of IgY is larger than that of its mammalian counterpart, while the molecular weight of the light chain of IgY is smaller. Second, upon pepsin digestion, anti-rabies virus IgY is degraded into Feb, in contrast to mammalian IgG, which has been reported to be degraded into F(ab')(2) under the same conditions. Copyright (C) 2001 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface plasmon resonance (SPR) technology and the Biacore biosensor have been widely used to measure the kinetics of biomolecular interactions in the fluid phase. In the past decade, the assay was further extended to measure reaction kinetics when two counterpart molecules are anchored on apposed surfaces. However, the cell binding kinetics has not been well quantified. Here we report development of a cellular kinetic model, combined with experimental procedures for cell binding kinetic measurements, to predict kinetic rates per cell. Human red blood cells coated with bovine serum albumin and anti-BSA monoclonal antibodies (mAbs) immobilized on the chip were used to conduct the measurements. Sensor-grams for BSA-coated RBC binding onto and debinding from the anti-BSA mAb-immobilized chip were obtained using a commercial Biacore 3000 biosensor, and analyzed with the cellular kinetic model developed. Not only did the model fit the data well, but it also predicted cellular on and off-rates as well as binding affinities from curve fitting. The dependence of flow duration, flow rate, and site density of BSA on binding kinetics was tested systematically, which further validated the feasibility and reliability of the new approach. Crown copyright (c) 2008 Published by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biosensor based on imaging ellipsometry (BIE) has been developed and validated in 169 patients for detecting five markers of hepatitis B virus (HBV) infection. The methodology has been established to pave the way for clinical diagnosis, including ligand screening, determination of the sensitivity, set-up of cut-off values (CoVs) and comparison with other clinical methods. A matrix assay method was established for ligand screening. The CoVs of HBV markers were derived with the help of receiver operating characteristic curves. Enzyme-linked immunosorbent assay (ELISA) was the reference method. Ligands with high bioactivity were selected and sensitivities of 1 ng/mL and 1 IU/mL for hepatitis B surface antigen (HBsAg) and surface antibody (anti-HBs) were obtained respectively. The CoVs of HBsAg, anti-HBs, hepatitis B e antigen, hepatitis B e antibody and core antibody were as follows: 15%, 18%, 15%, 20% and 15%, respectively, which were the percentages over the values of corresponding ligand controls. BIE can simultaneously detect up to five markers within 1 h with results in acceptable agreement with ELISA, and thus shows a potential for diagnosing hepatitis B with high throughput.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The FOB-3, anew type fiber optic biosensor, is designed to rapidly detect a variety of biological agents or analytes with better stability, sensitivity and specificity. In order to detect Y. Pestis, a sandwich immunoassay was developed by using the purified antibody against antigen FI immobilized on polystyrene probes as the capture antibody and the monoclonal antibody-Cy5 conjugate as the detector. After a series of optimization for the stability, sensitivity and specificity of the FOB-3, 50-1000 ng/ml of antigen FI and 6 x 10(1)-6 x 10(7) CFU/ml Y. pestis could be detected constantly in about 20 min, and Y pestis could be detected specifically from Y. pseudotuberculosis, Y. enterocolitica, B. anthracis and E. coli. Then, 39 blind samples, including 27 tissues of mice infected with Y pestis and 12 tissues of healthy mice as negative control, were detected with the FOB-3. 92.6% infected tissues were identified from the tissues of healthy mice and the tissues containing more than 100 CFU/ml bacteria could be detected by the biosensor. The results demonstrated the feasibility of the FOB-3 as an effective method to detect Y. pestis rapidly and directly from the infected animal specimens with the advantage of portability, simple-operation as well as high sensitivity and specificity. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

通过实验我们证明Ca2+对叶绿体膜的流动性,对PS I和PS II叶绿素蛋白质复合物的相对含量,以及PS I和PS II的多肽均有影响。 Ca2+对叶绿体膜表层的流动性影响不大,但降低了叶绿体膜深层脂质分子的流动性。从另一个角度阐明了Ca2+抑制光能从PS II向PS I传递的机制。 Ca2+可使PS I的21,23,110KD的多肽转移至PS II,LHCP1和LHCP2中的CF1的两个亚基(55,60KD)转至CPa和LHCP3,从而增加了PS II的捕光截面,引起激发能在两个系统之间的分配的改变。 用免疫学方法可以证明CPIa2和LHCP2的Ab为复合抗体,CPIa1的Ab为单抗,我们可以推测向日葵的不同叶绿素蛋白质复合物具有同源性。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complement-dependent antibody-mediated acute humoral rejection is the major obstacle of clinical transplantation across ABO incompatibility and human leukocyte antigen presensitization. We previously demonstrated that Yunnan-cobra venom factor (Y-CVF) cou

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The present study was undertaken to determine the role of preformed and induced anti-non-Gal antibodies in the rejection of hDAF pig-to-baboon kidney xenotransplants after anti-Gal antibody neutralization therapy. Methods. Seven baboons receiv

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expression of the histo-blood group carbohydrate structures T-nouvelle (Tn, CD175), sialylated To (CD175s) and the Thomsen-Friedenreich disaccharide (TF, CD176) on human leukemia cell lines was analyzed by their reactivity with specific monoclonal ant

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BALB/c mice were immunized intragastrically with human sperm. Cells from the Peyer's patches and spleens of the immunized mice were for the preparation of hybridomas secreting antisperm monoclonal IgA (mcIgA). The specific ratio of IgA-secreting cells in Peyer's patches was much higher than that in spleen. The binding site on human sperm of 9 of 19 mcIgA was in the post-acrosomal region using an immunofluorescent assay. Two of eight selected mcIgA caused strong human sperm agglutination and three of them produced significant inhibition of mouse in vitro fertilization. No mcIgA tested caused obvious human sperm immobilization or inhibited mouse in vivo fertilization. In vitro assembly of selected mcIgA in ascites with mouse secretory component (SC) caused no significant changes in effects on sperm function and in vitro fertilization. By use of Western blotting, dimer or higher polymers were demonstrated in all selected mcIgAs and corresponding protein antigens in 6 of 8 selected mcIgAs. These results suggest that human sperm function may be inhibited and fertilization rate reduced by specific secretory IgA to human sperm and that secretory immunity to protein antigens of human sperm could be induced by intragastrointestinal immunization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The anti-HIV-1 neutralizing antibody assay is widely used in AIDS vaccine research and other experimental and clinical studies. The vital dye staining method applied in the detection of anti-HIV-1 neutralizing antibody has been used in many laboratories. However, the unknown factor(s) in sera or plasma affected cell growth and caused protection when the tested sera or plasma was continuously maintained in cell culture. In addition, the poor solubility of neutral red in medium (such as RPMI-1640) also limited the use of this assay. Methods: In this study, human T cell line C8166 was used as host cells, and 3-(4,5-Dimethyl-2-thiazolyl)- 2,5-diphenyl-2H-tetrazolium bromide (MTT) instead of neutral red was used as vital dye. In order to avoid the effect of the unknown factor( s), the tested sera or plasma was removed by a washout procedure after initial 3 - 6 h culture in the assay. Result: This new assay eliminated the effect of the tested sera or plasma on cell growth, improved the reliability of detection of anti-HIV-1 neutralizing antibody, and showed excellent agreement with the p24 antigen method. Conclusion: The results suggest that the improved assay is relatively simple, highly duplicable, cost-effective, and well reliable for evaluating anti-HIV-1 neutralizing antibodies from sera or plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To understand better the molecular mechanisms of differential migration of antibody-secreting cells (ASCs) into mouse genital tracts, and regulation by sex hormones, surface markers, hormone receptors and adhesion molecules in mouse SG2 and PA4 hybridoma cells, respectively, secreting IgG2b and polymeric IgA antibody were detected by flow cytometry or RT-PCR. Semiquantitative RT-PCR was also used for measuring mRNA expression of adhesion molecules and chemokines (VCAM-1, ICAM-1, P-selectin, JAM-1 and CXCL12) in genital tracts of various adult mouse groups. The mRNAs of androgen receptor, estrogen receptor beta and CXCR4 were expressed in the ASCs. Sex hormones had no effect on expression of these molecules in ASCs. Except for VCAM-1, mRNA of all examined genes was expressed in normal mouse genital tracts. The mean of relative amounts of ICAM-1 and CXCL12 mRNA in all examined organs of females were higher (2.1- and 1.9-fold) than those in males. After orchiectomy or ovariectomy, the expression of ICAM-1, CXCL12 and P-selectin mRNA in the examined organs increased, except JAM-1 in male and CXCL12 in female. Sex hormone treatment recovered the changes to normal levels of mRNA expression in many examined genital tissues. In combination with our previous work, preferential migration of ASCs into female genital tract and regulation of migration by sex hormones are associated with expression patterns of adhesion molecules and chemokines in genital tract rather than in ASCs. (C) 2006 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinetics of mucosal and serum antibody response is well as antibody secreting cells (ASCs) production were studied in large yellow croaker following vaccination with inactivated Vibrio harveyi by different routes: oral administration. intraperitoneal (IP) injection and immersion. Indirect ELISA was used to measure the antibody level in serum and cutaneous mucus, and ELISPOT was used to monitor the ASCs derived from gill, blood and head kidney. The data demonstrated that IP injection resulted in the highest antibody levels in the systemic circulation, whereas immersion induced significant antibody levels in mucous. As for the ASCs response, IP injection induced high numbers of ASCs in the head kidney and blood; oral intubation only induced a slight ASCs response in the head kidney: immersion induced a much stronger ASCs response in the gill. These results indicate that mucosal antibodies following immersion immunization are independent of a systemic response and more sensitive, since it could be triggered earlier than serum antibodies. The mucosal antibodies following IP injection immunization may depend oil a systemic immune response. The protective effects of the three vaccination methods were compared by challenging with live V. harveyi. Survival of the three groups of vaccinated fish varied front 40 to 60%. while 100% mortality was found in control fish. Compared with IP and oral vaccination, immersion stimulated higher specific antibody titers in the mucosal system and achieved similar protection, so it is in effective and efficient method for immunizing a large number of fish against V harveyi (C) 2008 Elsevier B.V. All rights reserved.