47 resultados para Sample Preparation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several specific non-covalent protein complexes were successfully observed by matrix assisted desorption ionization mass spectrometry(MALDI MS). The methods described in this paper include the matrixes use of sinapinic acid(SA) and 6-aza-2-thiothymine (ATT) in neutral pH solution, as well as the improvement of two-layer sample preparation method to achieve a high sensitivity detection of stable non-covalent complexes, Myoglobin-heme complex was found simultaneously with the sinapinic acid matrix in the various pH solution(pH=2 or pH=5), The RNase S complex showed a striking intensity at the first shot, which was decreased with more laser shots. Most importantly, the observation of specific non-covalent complex in the brome mosaic virus(BMV) coat proteins would open up a new possibility to investigate the assembly and disassembly of viral capsids.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Matrix-assisted laser desorption ionization (MALDI) mass spectrometry is difficult for the characterization of noncovalent complexes hitherto because of the limitations in acidic matrix, sample preparation, laser-induced polymerization and adduct formation with matrix. Under our experimental conditions, sinapinic acid is used as a matrix, the specific noncovalent interactions of protein with fullerenols were observed by MALDI mass spectrometry. Some mass spectrometric features, such as mass shifts, broad adduct peaks and stoichiometries, showed that the specific non-covalent complexes between protein and fullerenols have been formed at a ratio of 1 : 4 for hemoglobin-fullerenols or 1 : 1 for myoglobin-fullerenols. The results implied that fullereneols could be used to protect partly hemoglobin from decomposition in acidic media, and therefore, it is possible to realize the molecular weight determination of a quaternary protein by MALDI mass spectrometry via the addition of specific organic compound in the matrix.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

激光诱导击穿光谱技术(LIBS)具有无需样品制备,原位快速分析,可进行实时控制的特点使其在钢铁冶炼控制中具有巨大的实际应用价值。本文以波长为1 064 nm的Nd∶YAG调Q固体激光器为激发光源,CCD为探测器,高合金钢GBW01605—01609系列为样品,在建立的LIBS实验装置上研究激光与合金钢之间的相互作用。系统地研究了观测距离、激光能量对高合金钢样品中激光诱导击穿谱特性的影响,并分析了LIBS信号的时间分辨特性,确定了将LIBS用于合金钢微量元素定量分析时的最佳实验条件。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The most novel aspect of this thesis is the combination analysis of the boron isotopes and trace elements. What’s more, it also provides a reliable analytical technique, which is suitable for both boron isotopes and trace elements. Al/Ca values can be used to monitor the clay removal during the sample preparation. It is found that when Al/Ca>100 mol/mol, the measured boron isotopic compositions are always several permil lower than those properly cleaned. B/Ca ratios can be used to calculate the exact boron loaded for each sample. Otherwise, too much loading will lead to too long time for the whole analytical sequence, and too less loading might incur serious blank problem. One other benefit besides those discussed above is that the combination analysis of boron isotopes and trace elements on the same sample allows reconstruction of the marine carbonate system and atmospheric pCO2 without assumption of the other parameter. In the marine carbonate system, with the seawater pH from the foraminiferal 11B, one has to make an assumption on the other variable to obtain the rest four variables. A series studies found that U/Ca and B/Ca are potential proxies for seawater [CO32-]and [HCO3-], respectively. Since they are measured on the same sample with boron isotopes, hence, there is no spatial or temporal ambiguity in the incorporation of the two controlling parameters. With 11B and U/Ca, the reconstructed atmospheric pCO2 variations match the atmospheric pCO2 record from the Vostok ice core within ±20 ppm. The incorporations of U and B into foraminiferal carbonates are controlled by the overall growth rate of individual foraminifers and other possible factors. The reliable application of these proxies still require further calibrations. In a similar fashion, the combination analysis of boron isotopes and Mg/Ca also has great advantages. Mg/Ca has been proved to be a reliable proxy for the surface seawater temperature. With the combination analysis, one can determine the phase between changes in atmospheric pCO2 and surface seawater temperature, thus explore the cause and mechanism of the changes in atmospheric pCO2. .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main research projects reported in this paper are the establishment of a luminescence (OSL/TL) dating laboratory in The Institute of Geology and Geophysics, CAS, and studies on OSL dating technique and protocol of sediments from North China. These projects have been suggested in order to fit in with the needs of research developments in environmental changes, in particular the aridity and desertification in North China. A new luminescence dating laboratory in which there are a Rise TL/OSL-DA-15B/C reader with Sr-90 beta source, a set of Little More Tape 9022 alpha and beta irradiators, three set of Daybreak 583 intelligent alpha counters and sample preparation system has been set up in the Institute in June 2001. The courses of the establishment of a new laboratory involved a series of technical works, besides making a suitable choice of the equipment, as follows: installing and testing TL/OSL reader, calibrating the dose rate of the beta and alpha sources in the irradiators with the standard sources, testing and calibrating the count rates of the thick source alpha counting in the alpha counters with a standard sample, and then dating of the know age samples to check and examine the OSL/TL dating system. All data obtained from above calibrations and tests show that the established OSL/TL system, including the used equipment in it, can be used to determine age of the geological and archaeological samples with an error of equivalent dose (De) of less than 5%. The OSL dates of several sediment samples obtained from the system are good agreement with those from the OSL dating laboratory in Hong Kong University and ~(14)C dates within 1 - 2 standard deviations. The studies on OSL dating technique and protocol of sediment samples being in progress involve the De determinations with single aliquot regeneration (SAR) (Murray and Wintle, 2000) of the coarse grain quartz from sand dune samples and comparison of the De determinations obtained from SAR with those measured by using multiple aliquot regeneration of loess fine grains. The preliminary results from these research works are shown as follows. The very low natural equivalent dose (De) of about 0.012 - 0.03 Gy, corresponding age of less than 10 years, for BLSL (blue light stimulated luminescence) of the coarse grain quartz from modern sand dune samples in Horqin sand fields has been determined with both the SAR and multiple aliquot regeneration (MAR) techniques. This imply that the BLSL signal zeroing of the quartz could be reached before burying of the sand in Horqin sand fields. The De values and ages of the coarse grain quartz measured with SAR protocol are in good agreement with those obtained from multiple aliquot technique for the modern sand dune samples, but the errors of De from the MAR is greater than those from the SAR. This may imply that the higher precision of age determination for younger sand dune samples could be achieved with the SAR of coarse grain quartz. The MAR combining with "Australian Slide method" may be a perfect choice for De measurements of loess fine grain samples on the basis of analysis of De values obtained from the SAR and from the MAR. The former can be employed to obtain a reliable age estimate of loess sample as older as approximately SO ka BR There is a great difference between De determinations from the (post-IR) OSL of the SAR (Roberts and Wintle, 2001) and those from independent or expected estimates for the older samples. However, the age estimates obtained from the (post-IR) OSL of the SAR are mostly closed to the independent age determinations for the younger (age less than 10 ka) fine grain samples. It may be suggested that the (post-IR) OSL of the SAR protocol of the fine grain fraction would be a suitable choice to dating of the younger samples, but may be unsuitable for the older samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Oxidized carbon nanotubes are tested as a matrix for analysis of small molecules by matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS). Compared with nonoxidized carbon nanotubes, oxidized carbon nanotubes facilitate sample preparation because of their higher solubility in water. The matrix layer of oxidized carbon nanotubes is much more homogeneous and compact than that of nonoxidized carbon nanotubes. The efficiency of desorption/ionization for analytes and the reproducibility of peak intensities within and between sample spots are greatly enhanced on the surface of oxidized carbon nanotubes. The advantage of the oxidized carbon nanotubes in comparison with alpha-cyano-4-hydroxycinnamic acid (CCA) and carbon nanotubes is demonstrated by MALDI-TOF-MS analysis of an amino acid mixture. The matrix is successfully used for analysis of synthetic hydroxypropyl P-cyclodextrin, suggesting a great potential for monitoring reactions and for product quality control. Reliable quantitative analysis of jatrorrhizine and palmatine with a wide linear range (1-100 ng/mL) and good reproducibility of relative peak areas (RSD less than 10 %) is achieved using this matrix. Concentrations of jatrorrhizine (8.65 mg/mL) and palmatine (10.4 mg/mL) in an extract of Coptis chinensis Franch are determined simultaneously using the matrix and a standard addition method. (c) 2005 American Society for Mass Spectrometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the space selective precipitation of Pd nanoparticles in Pd2+ -doped silicate glass by ultrashort laser pulses irradiation and further annealing. Absorption spectra, transmission electron microscopy, refractive index measurement and Z-scan technique demonstrated that metallic Pd nanoparticles were precipitated in the glass sample after irradiation by an 800-nm femtosecond laser and subsequent annealing at 600 degrees C. We discuss a refractive index change and nonlinear absorption that combines the precipitation of Pd nanoparticles. Crown Copyright (c) 2005 Published by Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fluorescence immunoassay for human IgG (Ag) was developed using a pH-sensitive polymer prepared by thermal initiation or redox initiation polymerization as a carrier. In the competitive immunoassay, appropriate quantity of Ag was immobilized on the polymer and the standard Ag (or sample) solution, and a constant amount of fluorescein isothiocyanate labeled goat anti-human IgG antibody (Ab-FITC) was added. Immobilized Ag and the standard (or sample) Ag competed for binding to the Ab-FITC in 37 C in homogeneous format. After changing the pH to separate the polymer-immune complex precipitate, it was re-dissolved and determined by fluorescence method. The results showed that the immobilization efficiency, immunological reaction activities of immobilized Au and phase transition pH range were improved as Ag was immobilized by thermal initiation instead of redox initiation polymerization. Under optimum conditions, the calibration graphs for the Ag in both methods, thermal initiation and redox initiation, were linear over the concentration range of 0.0-1000 ng mL(-1), with detection limits 8 (thermal initiation) and 12 ng mL(1) (redox initiation), respectively. Moreover, some pH-sensitive polymer prepared only in organic solvent or under high temperature could also be used as an immunoreaction carrier by thermal initiation polymerization. Thermal initiation polymerization was a better immobilization mode. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Al-doped and B, Al co-doped SiO2 xerogels with Eu2+ ions were prepared only by sol-gel reaction in air without reducing heat-treatment or post-doping. The luminescence characteristics and mechanism of europium doping SiO2 xerogels were studied as a function of the concentration of Al, B, the europium concentration and the host composition. The emission spectra of the Al-doped and B, Al codoped samples all show an efficient emission broad band in the blue violet range. The blue emission of the Al-doped sample was centered at 437 nm, whereas the B, Al co-doped xerogel emission maximum shifted to 423 nm and the intensity became weaker. Concentration quenching effect occurred in both the Al-doped and B, Al co-doped samples, which probably is the result of the transfer of the excitation energy from Eu2+ ions to defects. The highest Eu2+ emission intensity was observed for samples with the Si(OC2H5)(4):C2H5OH:H2O molar ratio of 1:2:4. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The deposition rate and refractive index for a-Si(amorphous silicon) and SiO2 grown by PECVD were studied under different pressure, power and proportion of reactant source gases. a-Si/SiO2 MQW(multi-quantum well) with high quality was deposited under suitable conditions, in which the thickness of the a-Si layers is several nanometers. The sample of a-Si/SiO2 MQW was crystallized by laser annealing. Because of the confinement of the SiO2 layers, crystalline grains were formed during the a-Si layers were being crystallized. The size of the crystalline grains were not more than the thickness of the a-Si layers. The a-Si layers were crystallized to be nanometer crystalline silicon(nc-Si), therefore, nc-Si/SiO2 MQW was formed. For the a-Si/SiO2 MQW with 4.0nm a-Si wells separated by 5nm SiO2 barries, most of the a-Si were crystallized to silicon grains after laser annealing,and the size of the grains is 3.8nm. Strong photoluminescence with three peaks from the nc-Si/SiO2 MQW was detected at 10K. The wavelength of the peaks were 810nm, 825nm and 845nm, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Highly active PtSn/C catalyst was prepared by a polyol method. The catalyst was reduced in H-2/Ar atmosphere at 600 degreesC for 2 h in order to obtain different metallic phase. TEM images show uniform dispersion of spherical metal nanoparticles with average diameters of 1.8 and 3.9 nm for the as-prepared and treated catalysts, respectively. UV-vis spectrophotometry is employed to monitor the preparation process and the results indicate that Pt-Sn complex formed once the precursors of Pt and Sn were mixed together. The structure properties of the samples were characterized using X-ray diffraction. The results show that after reduction, the catalyst tends to form PtSn alloy. TPR experiment results show that Sn exists in multivalent state in the as-prepared sample while only zero-valence Sn was detected in the treated sample, while it could not be excluded that the multivalent tin existed in the treated sample. Cyclic voltammetry (CV) technique and single direct ethanol fuel cell (DEFC) tests indicate that the as-prepared catalyst possesses superior catalytic activity for ethanol oxidation to the treated sample. The results suggest that Pt and multivalent Sn are the active species for ethanol oxidation. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Long methacrylate monolithic columns (100 cm x 320 mum i.d.) were prepared from silanized fused-silica capillaries of 320 mum i.d. by in situ copolymerization of butyl methacrylate (BMA) with ethylene dimethacrylate (EDMA) in the presence of a suitable porogen. The separation performance and selectivity of the column were evaluated and compared with a 25 cm x 320 mum i.d. column prepared in the same way by capillary high-performance liquid chromatography (mu-HPLC) The results showed that the 1 m long monolithic column can generate 33 x 10(3) plate number and exhibited good permeability, higher sample loadability, and separation capability. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A facile, efficient way to fabricate macroscopic soft colloidal crystals with fiber symmetry by drying a latex dispersion in a tube is presented. A transparent, stable colloidal crystal was obtained from a 25 wt % latex dispersion by complete water evaporation for 4 days. The centimeter-long sample was investigated by means of synchrotron small-angle X-ray diffraction (SAXD). Analysis of a large number of distinct Bragg peaks reveals that uniaxially oriented colloidal crystals with face-centered cubic lattice structure were formed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mg-3Al-0.5Mn-0.5Zn-1MM alloy was prepared by metal mould casting method. The as-cast ingot was homogenized and then hot-rolled at 673 K with total thickness reduction of 65%. Microstructure and mechanical properties of the as-cast and hot-rolled samples were investigated. The results showed that the as-cast sample mainly consisted of alpha-Mg, beta-Mg17Al12, Al10Ce2Mn7, and Al11RE3 (RE = La and Ce) phases. The average grain size of the sample homogenized at 673 K was about 240 gm, and it was greatly refined to about 7 mu m by dynamic recrystallization for the hot-rolled sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the paper, we report an efficient method to prepare high yield (up to 97%) of silver nanoplates. Synthesis of silver nanoplates was carried Out in a binary solvent system of N,N-dimethylformamide (DMF) and toluene, in which DMF served as the reductant and polyvinylpyrrolidone (PVP) as the capping agent. By increasing the ratio of toluene to DMF to 7:6, silver nanoplates can be Successfully synthesized; otherwise other shaped nanoparticles would be the major products. The nanoplate sample was characterized by TEM, HRTEM, SAED, XRD, AFM and UV-visible spectroscopy, proving the high nanoplate purity of this sample. The influence of toluene content, other solvents, AgNO3 concentration, preparation temperature and chloride ions was also examined, which suggests that the function of nonpolar solvents in this system is to enhance the PVP coverage on silver surface and, furthermore, to facilitate the preferential adsorption of PVP on two (I I I) facets of silver nanoplates.