30 resultados para SAMPLE VARIANCES
Resumo:
IEECAS SKLLQG
Resumo:
Laser-induced breakdown spectroscopy (LIBS) as a powerful analytical technique is applied to analyze trace-elements in fresh plant samples. We investigate the LIBS spectra of fresh holly leaves and observe more than 430 lines emitted from 25 elements and molecules in the region 230-438 nm. The influence of laser wavelength on LIBS applied to semi-quantitative analysis of trace-element contents in plant samples is studied. The results show that the UV laser has lower relative standard deviations and better repeatability for semi-quantitative analysis of trace-element contents in plant samples. This work may be helpful for improving the quantitative analysis power of LIBS applied to plant samples.
Resumo:
An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 muL and a washing solvent loop of 0.5 muL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
A minicapillary viscometer utilizing <0.5 ml of sample at a volume fraction of <0.1% is described. The calculated a/b of DPPC/DPPG multilamellar liposome was 1.14 as prolate ellipsoids and a/b of dioleoylpropyltrimethyl ammonium methylsulfate-DNA complex at a charge ratio of 4: 1 (+/-) was 3.7 as prolate ellipsoids or 4.9 as oblate ellipsoids. The deviation of shape from perfect sphere is thus expressed quantitatively in more than two significant figures. In these measurement, the necessary amount of DNA is <0.5 mg.
Resumo:
An apparatus including a rotary-type injector was designed for quantitative sample injection in capillary electrophoresis (CE), in which both pressurized flow and electroosmotic flow were used to drive the background electrolyte solution. A relative standard deviation of peak area of lower than 1% was achieved by using this apparatus. The effects of back-pressure regulator, restrictor, and applied voltage on separation efficiency and resolution were investigated. The utility of this apparatus in both micro-HPLC and pressurized capillary electrochromatography (pCEC) was also demonstrated.
Resumo:
Single-walled carbon nanohorn (SWCNH) was developed as new adsorbent for solid-phase extraction using 4-nitrophenol as representative. The unique exoteric structures and high surface area of SWCNH allow extracting a large amount of 4-nitrophenol over a short time. Highly sensitive determination of 4-nitrophenol was achieved by linear sweep voltammetry after only 120 s extraction. The calibration plot for 4-nitrophenol determination is linear in the range of 5.0 x 10(-8) M-1.0 x 10(-5) M under optimum conditions. The detection limit is 1.1 x 10(-8) M. The proposed method was successfully employed to determine 4-nitrophenol in lake water samples, and the recoveries of the spiked 4-nitrophenol were excellent (92-106%).
Resumo:
Capillary electrophoresis (CE) with Ru(bpy)(3)(2+) electrochemiluminescence. (ECL) detection system was established to the determination of contamination of banknotes with controlled drugs and a high efficiency on-column field-amplified sample stacking (FASS) technique was also optimized to increase the ECL intensity. The method was illustrated using heroin and cocaine, which are two typical and popular illicit drugs. Highest sample stacking was obtained when 0.01 mM acetic acid was chosen for sample dissolution with electrokinetical injection for 6 s at 17 kV. Under the optimized conditions: ECL detection at 1.2 V, separation voltage 10.0 kV, 20 mM phosphate-acetate (pH 7.2) as running buffer, 5 mM Ru(bpy)(3)(2+) with 50 mM phosphate-acetate (pH 7.2) in the detection cell, the standard curves were linear in the range of 7.50 x 10(-8) to 1.00 x 10(-5) M for heroin and 2.50 x 10(-7) to 1.00 x 10(-4) M for cocaine and detection limits of 50 nM for heroin and 60 nM for cocaine were achieved (S/N = 3), respectively. Relative standard derivations of the ECL intensity and the migration time were 3.50 and 0.51% for heroin and 4.44 and 0.12% for cocaine, respectively.The developed method was successfully applied to the determination of heroin and cocaine on illicit drug contaminated banknotes without any damage of the paper currency.
Resumo:
The determination of Nb and Ta in Nb-Ta minerals was accomplished by slurry nebulization inductively coupled plasma optical emission spectrometry (ICP-OES), using a clog-free V-groove ceramic nebulizer. Samples were first wet-ground to appropriate particle sizes with narrow size distribution and 90% of the particles in the slurry were smaller than 2.32 mu m in diameter. Subsamples were then dispersed in pH 9 aqueous solutions, and agitated in an ultrasonic bath for 15 min prior to analysis. Due to the lack of slurry standards matching well with the samples, calibration was simply carried out using aqueous solution standards. Results were compared with those obtained from a conventional fusion decomposition procedure and acid digestion procedures and a good agreement between the measured and referred values was obtained. The technique provided a good alternative for the rapid determination of Nb and/or Ta in their corresponding minerals.
Resumo:
A new electrochemiluminescence (ECL) microoptoprobe with simple structure. small sampling volume and high efficiency was developed. It was constructed by fixing the transparent gold mini-grid on the end surface of the optical fiber, and by surrounding the fiber with the counter- and reference electrodes to form a self-contained three-electrode system. The use of mini-grid electrode increased the surface area and collection efficiency. which resulted in higher ECL signal and better sensitivity. The counter electrode together with one end of the fiber formed a mini-vessel, which eliminated the need of additional container and allowed to perform ECL detection in a very small volume (about 10 mul). The microoptoprobe obtained was characterized with the Ru(bpy)(3)(2-)-tripropylamine system and was applied for the determination of oxalate and chlorpromazine (CPZ). Detection limits (S/N = 3) were 5 x 10(-7) and 1 x 10(-6) mol l(-1) for oxalate and CPZ. respectively. The linear range for oxalate and CPZ extended from 1 x 10(-6) to 1 x 10(-3) mol l(-1), and from 5 x 10(-6) to 5 x 10(-4) mol l(-1). respectively.
Resumo:
The process of deoxyribonucleio acid (DNA) sample preparation in scanning tunneling microscope (STM) and atomic force microscope (AFM) is reviewed. The main discussions are devoted to the methods, advantages or drawbacks and improvement of the DNA sample's immobilization and spreading.
Resumo:
The community structure and vertical distribution of prokaryotes in a deep-sea (ca. 3,191 m) cold sediment sample (ca. 43 cm long) collected at the East Pacific Rise (EPR) similar to 13 degrees N were studied with 16SrDNA-based molecular analyses. Total community DNA was extracted from each of four discrete layers EPRDS-1, -2, -3 and -4 (from top to bottom) and 16S rDNA were amplified by PCR. Cluster analysis of DGGE profiles revealed that the bacterial communities shifted sharply between EPRDS-1 and EPRDS-2 in similarity coefficient at merely 49%. Twenty-three sequences retrieved from DGGE bands fell into 11 groups based on BLAST and bootstrap analysis. The dominant groups in the bacterial communities were Chloroflexi, Gamma proteobacteria, Actinobacterium and unidentified bacteria, with their corresponding percentages varying along discrete layers. Pairwise Fst (F-statistics) values between the archaeal clone libraries indicated that the archaeal communities changed distinctly between EPRDS-2 and EPRDS-3. Sequences from the archaeal libraries were divided to eight groups. Crenarchaea Marine Group I (MGI) was prevalent in EPRDS-1 at 83%, while Uncultured Crenarchaea group II B (UCII B) abounded in EPRDS-4 at 61%. Our results revealed that the vertically stratified distribution of prokaryotic communities might be in response to the geochemical settings and suggested that the sampling area was influenced by hydrothermalism. The copresence of members related to hydrothermalism and cold deep-sea environments in the microbial community indicated that the area might be a transitional region from hydrothermal vents to cold deep-sea sediments.
Resumo:
The arguments on self discrepancy can be traced back to the old ages, but the systematic investigations were started by Higgins et al. at 1985.Compared to the large number of foreign studies, only a few ones have been conducted in our own country. Numerous characteristics of undergruaduate’s actual-ideal discrepancy and a great many determinative factors have been found as well as many of its negative effects—especially the greater the actual-ideal discrepancy, the more negative on the mind and behavior. Nevertheless, there are still many issues to be solved, such as the extend of the undergruaduate’s actual-ideal discrepancy level in own country. On the other hand, although there are a great many internal and external determinative factors of actual-ideal discrepancy, how they overally influence the discrepancy of the same individual is still unknown; to what extent does actual-ideal discrepancy influence the human mind and behavior and whether the influence is positive or negtive? This research collected a sample consisting of 4 undergraduate grades and 5 majors from a middle-ranked university. We adopted questionnaires in the study, and analyzed the data using correlation analysis, regression analysis, variances analysis, and path analysis. Our aim focused on the general characteristics of the undergruaduate’s actual-ideal discrepancy in own country, the overall working mechanism of the determinative factors including environmental and personal factors on the actual-ideal discrepancy of the same individual, and the effects of the actual-ideal discrepancy on psychological adaption, motivation, and behavior. The main results are as following: (1)The improved measurement instrument possesses good validity and reliability, and can be used in future research. (2) The actual-ideal discrepancy level among undergraduates is slightly bellow medium. The proportion of undergraduates who have a higher actual-ideal discrepancy level is small. There is significant gender difference in actual-ideal discrepancy level, but no significant difference across different majors and grades. (3)This research probed the overall working mechanism of the parenting style(environmental factors) and the personality factors(personal factors) including stability, flexibility, cleverness, and esteem on the undergruaduate’s actual-ideal discrepancy. The results shows that the parenting style of warmth and understanding, stability, flexibility, and esteem influence the actual-ideal discrepancy. Esteem entirely moderate the relationship between the parenting style of warmth and understanding and actual-ideal discrepancy, partially moderate the relationship between the flexibility, stability and actual-ideal discrepancy. Furthermore, the above factors can be order as stability, flexibility, and parenting style of warmth and understanding in terms of decreasing impact on the actual-ideal discrepancy. No significant effect of cleverness and other parenting style was found. The parenting style of warmth and understanding, stability, and flexibility interactively influence the actual-ideal discrepancy in the following manner: the stability and flexibility, both of which have independent influence on the actual-ideal discrepancy, entirely moderate the relationship between the parenting style of warmth and understanding and actual-ideal discrepancy. (4) Actual-ideal discrepancy plays a negative role in adaption indices, including self-efficacy, self-identity, self-actualization. Actual-ideal discrepancy also has negative effects on the 9 symptoms measured by SCL-90, vitality, approach motivation, avoidance motivation, and performance goals. No significant influence on mastering goals was found. Actual-ideal discrepancy uniquely correlates with depression symptom. The above results contribute from the point of self-discrepancy to the understanding of self-identity of undergraduates, and they enrich the knowledge of the development of self and contribute to the understanding of the development of human personality.This research advances on the two key problems of the developmental mechanism of actual-ideal discrepancy and that promotes the knowledge of the developmental mechanism of actual-ideal discrepancy. The research probed the relationship between the actual-ideal discrepancy and motivation which is an important phenomenon and this enlarges the domain of the actual-ideal discrepancy research. The results make sure that actual-ideal discrepancy is one of the important factors influencing undergruaduate’s mind and behavior. The conclusions can provide reference and guidance in the diagnosis and intervension strategies for mental health education and counseling practice in university.
Resumo:
A method has been developed for determining of heavy metal ions by field-amplified sample injection capillary electrophoresis with contactless conductivity detection. The effects of the 2-N-morpholinoethanesulfonic acid/histidine (MES/His) concentration in the sample matrix, the injection time and organic additives on the enrichment factor were studied. The results showed that MES/His with a low concentration in the sample matrix, an increase of the injection time and the addition of acetonitrile improved the enrichment factor. Four heavy metal ions (Zn2+, Co2+, Cu2+ and Ni2+) were dissolved in deionized water, separated in a 10 mM MES/His running buffer at pH 4.9 and detected by contactless conductivity detection. The detection sensitivity was enhanced by about three orders of magnitude with respect to the non-stacking injection mode. The limits of detection were in the range from 5 nM (Zn2+) to 30 nM (Cu2+). The method has been used to determine heavy metal ions in tap water.