23 resultados para Optical testing
Resumo:
利用热弹性理论分析了在光学材料中由于缺陷吸收激光能量引起的温度和热应力分布,并且针对一个简单的裂纹模型分析了热应力产生的应力强度因子,给出了一些主要参数对于应力强度因子的影响的规律。
Resumo:
An optical diagnostic system consisting of the Michelson interferometer with the image processor has been developed for the study of the kinetics of the thermal capillary convection. The capillary convection, surface deformation, surface wave and the velocity field in a rectangular cavity with different temperature's sidewalls have been investigated by optical interference method and PIV technique. In order to calculate the surface deformation from the interference fringe, Fourier transformation is used to grating analysis. The quantitative results of the surface deformation and surface wave have been calculated from the interference fringe pattern.
Resumo:
The microstructural evolution in localized shear deformation was investigated in an 8090 Al-Li alloy by split Hopkinson pressure bar (strain rate of approximately 10(3) s(-1)) at ambient temperature and 77 K. The alloy was tested in the peak-, over-, under-, and natural-aged conditions, that provide a wide range of microstructural parameters and mechanical properties. Two types of localized shear bands were distinguished by optical microscopy: the deformed shear band and the white-etching shear band. They form at different stages of deformation during localization. There are critical strains for the occurrence of deformed and white-etching localized shear deformation, at the imposed strain rate. Observations by transmission electron microscopy reveal that the white-etching bands contain fine equiaxed grains; it is proposed that they are the result of recrystallization occurring during localization. The deformed-type bands are observed after testing at 77 K in all heat treatment conditions, but they are not as well defined as those developed at ambient temperature. Cracking often occurs along the localized shear at ambient temperature. The decrement in temperature is favorable for the nucleation, growth and coalescence of the microcracks along the shear bands, inducing fracture.
Resumo:
Turbidity measurement for the absolute coagulation rate constant of suspensions has been extensively adopted because of its simplicity and easy implementation. A key factor to derive the rate constant from experimental data is how to theoretically evaluate the so-called optical factor involved in calculating the extinction cross section of doublets formed in the aggregation. In a previous paper, we have shown that compared with other theoretical approaches, the T-matrix method provides a robust solution to this problem and is effective in extending the applicability range of the turbidity methodology as well as increasing measurement accuracy. This paper will provide a more comprehensive discussion about the physical insight of using the T-matrix method in turbidity measurement and associated technical details. In particular, the importance of ensuring the correct value for the refractive indices for colloidal particles and the surrounding medium used in the calculation is addressed because the indices generally vary with the wavelength of the incident light. The comparison of calculated results with experiments shows that the T-matrix method can correctly calculate optical factors even for large particles, whereas other existing theories cannot. In addition, the calculated data of the optical factor by the T-matrix method for a range of particle radii and incident light wavelengths are listed.
Resumo:
Abstract: Avidin layer was bound on the substrate surface of Silicon wafer modified with aldehyde. The interaction between avidin and biotin was adopted for the immobilization of mouse monoclonal biotin-anti-M13 (antibody GP3)-labeled biotin. The surface was incubated in a solution containing phage M13KO7, which was trapped by the antibody GP3 with the interaction between phage M13KO7 and antibody GP3, resulting in a variation of layer thickness that was detected by imaging ellipsometry. The results showed a saturated layer of antibody GP3 with a thickness about 6.9 nm on the surface of the silicon wafer. The specific interaction between phage M13KO7 and antibody GP3 resulted in a variation of layer thickness. The layer of phage M13KO7 bound with antibody GP3 was 17.5 nm in the concentration of 1.1×1010 pfu/mL. Each variation of the layer thickness corresponded to a concentration of phage M13KO7 in the range of 0.1×1010–2.5×1010 pfu/mL, with the sensitivity of 109 pfu/mL. Compared with other methods, the optical protein-chip, requiring only short measurement time, label free, is a quantitative test, and can be visualized. This study could be significant on the interactions between the antibody and the virus, showing potential in the early diagnosis of virosis.
Resumo:
A reliable validation based on the optical flow visualization for numerical simulations of complex flowfields is addressed in this paper. Several test cases, including two-dimensional, axisymmetric and three-dimensional flowfields, were presented to demonstrate the effectiveness of the validation and gain credibility of numerical solutions of complex flowfields. In the validation, images of these flowfields were constructed from numerical results based on the principle of the optical flow visualization, and compared directly with experimental interferograms. Because both experimental and numerical results are of identical physical representation, the agreement between them can be evaluated effectively by examining flow structures as well as checking discrepancies in density. The study shows that the reliable validation can be achieved by using the direct comparison between numerical and experiment results without any loss of accuracy in either of them.
Resumo:
Protein-Chip as micro-assays for the determination of protein interaction, the analysis, the identification and the purification of proteins has large potential applications. The Optical Protein-Chip is able to detect the multi-interaction of proteins and multi-bio-activities of molecules directly and simultaneously with no labeling. The chip is a small matrix on solid substrate containing multi-micro-area prepared by microfabrication with photolithography or soft lithography for surface patterning, and processed with surface modification which includes the physical, chemical, and bio-chemical modifications, etc. The ligand immobilization, such as protein immobilization, especially the oriented immobilization with low steric hindrance and high bio-specific binding activity between ligand and receptor is used to form a sensing surface. Each area of the pattern is corresponding to only one bioactivity. The interval between the areas is non-bioactive and optically extinctive. The affinity between proteins is used to realize non-labeling microassays for the determination of protein identification and protein interaction. The sampling of the chip is non-disturbing, performed with imaging ellipsometry and image processing on a database of proteins.