26 resultados para Myoelectric signals


Relevância:

20.00% 20.00%

Publicador:

Resumo:

All-optical clock recovery for the return-to-zero modulation format is demonstrated experimentally at 40 Gbits/s by using an amplified feedback laser. A 40 GHz optical clock with a root-mean-square (rms) timing jitter of 130 fs and a carrier-to-noise ratio of 42 dB is obtained. Also, a 40 GHz optical clock with timing jitter of 137 fs is directly recovered from pseudo-non-return-to-zero signals degraded by polarization-mode dispersion (PMD). No preprocessing stage to enhance the clock tone is used. The rms timing jitter of the recovered clock is investigated for different values of input power and for varying amounts of waveform distortion due to PMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In present paper, a new Micromegas detector is developed, and its time and energy signals are obtained in the figure form. The rising time of fast time signal is less than 2 ns due to the very fast collection of avalanche electrons, and the rising time of the energy pulse is about 100 ns, which is corresponding to the total collecting time of the electrons and ions in the avalanche process. The counter plateau, energy resolution and the gas gains of the detector have been compared with other groups' experimental results and the Garfield simulation result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-hit 3-layer delay-line anode (Hexanode) has an increased ability to detect multi-hit events in a collision experiment. Coupled with a pair of micro-channel plates, it can provide position information of the particles even if the particles arrive at the same time or within small time dwell. But it suffers from some ambiguous outputs and signal losses due to timing order and triggering thresholds etc. We have developed a signal reconstruction program to correct those events. After the program correction, the dead time only exists when 2 paxticles arrive at the same time and the same position within a much smaller range. With the combination of Hexanode and the program, the experimental efficiencies will be greatly improved in near threshold double ionization on He collisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

National Key Research and Development Program [2010CB833502]; National Natural Science Foundation of China [30600071, 40601097, 30590381]; Chinese Academy of Sciences [KZCX2-YW-432, O7V70080SZ, LENOM07LS-01]; GUCAS [O85101PM03]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A field population of Ulva pseudocurvata Koeman et C. Hoek (hereafter termed Ulva) at Sylt Island (North Sea, Germany) exhibited biweekly peaks of gametophytic reproduction during the colder seasons and approximately weekly peaks during summer. The reproductive events lasted 1-5 d and were separated from each other by purely vegetative phases. Under constant conditions in the laboratory, a free-running rhythm was observed with reproductive peaks occurring approximately every 7 d. When artificial moonlight was provided every 4 weeks, fewer reproductive events occurred, and the reproductive rhythm became synchronized to the environmental artificial moonlight rhythm. In the laboratory, apical disks were entirely converted into reproductive tissue after 8 d cultivation, while almost all basal disks stayed vegetative, which prevented the entire loss of the vegetative thallus during reproductive events. Seasonal size reduction of the thallus occurred from late autumn onward and was determined to be controlled by a genuine photoperiodic response, since size reduction could be induced from May onward by experimental short-day (SD) treatment but was prevented in a long-day (LD) or night-break regime (NB). A daily fine-tuning occurred with gamete release early in the morning at the first sign of daylight, following an obligatory dark ("night") period of at least 1 h duration. No release took place if the overnight dark phase was replaced by continuous light. Blue, green, or red light all triggered gamete release after a dark phase at an irradiance of 0.1 mu mol photons . m(-2) .s(-1), while 0.001 mu mol photons . m(-2) . s(-1) was equivalent to a dark control.