19 resultados para Human response


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automated biomolecular interaction analysis instrument (BI-Acore) based on surface plasmon resonance (SPR) has been used to determine human immunoglobulin G (IgG) in real time. Polyclonal anti-human IgG antibody was covalently immobilized to a carboxymethyldextran modified gold film surface. The samples of human IgG prepared in HBS buffer were poured over the immobilized surface. The signal amplification antibody was applied to amplify the response signal. After each measurement, the surface was regenerated with 0.1 mol/L H3PO4. The assay was rapid, requiring only 30 min for antibody immobilization and 20 min for each subsequent process of immune binding, antibody amplification and regeneration. The antibody immobilized surface had good response to human IgG in the range of 0.12-60 nmol/L with a detection limit of 60 pmol/L. The same antibody immobilized surface could be used for more than 110 cycles of binding, amplification and regeneration. The results demonstrate that the sensitivity, specificity and reproducibility of amplified immunoassay using real-time BIA technology are satisfactory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using an enhanced surface plasmon resonance (SPR) immunosensor, we have determined the concentration of human complement factor 4 (C4). Antibody protein was concentrated into a carboxymethyldextran-modified gold surface by electrostatic attraction force and a simultaneous covalent immobilization of antibody based on amine coupling reaction took place. The sandwich method was applied to enhance the response signal and the specificity of antigen binding assay. The antibody immobilized surface had good response to C4 in the range of 0.02-20 mug/ml by this enhanced immunoassay. The regeneration effect by pH 2 glycine-HC1 buffer was also investigated. The same antibody immobilized surface could be used more than 80 cycles of C4 binding and regeneration. In addition, the ability to determinate C4 directly from serum sample without any purification was investigated. The sensitivity, specificity and reproducibility of the enhanced immunoassay are satisfactory. The results clearly demonstrate the advantages of the enhanced SPR technique for C4 immunoassay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1.0 moll(-1) HCl with a pulse current density of 20 mA cm(-2), and the pulse wave parameters of t(a)/t(c) = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t(r)) to the working time (t(w)) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 moll(-1) KCl was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MEP is a member of thioester-containing protein (TEP) family found in Zhikong scallop Chlamys farreri and is involved in innate immunity against invading microbes. In the present study, the genomic DNA of CfTEP was cloned and characterized. The genomic DNA sequence of CfTEP consisted of 40 exons and 39 introns spanning 35 kb with all exon-intron junction sequences agreeing with the GT/AG consensus. The genomic organization of CfTEP was similar to human and mouse 0 rather than ciona C3-1 and Drosophila dTEP2. By RT-PCR technique, seven different cDNA variants of CfTEP (designated as CfTEP-A-CfTEP-G) were cloned from scallop gonad. CfTEP-A-CfTEP-F were produced by alternative splicing of six mutually exclusive exons (exons 19-24), respectively, which encoded the highly variable central region. While in CfTEP-G, the deletion of all the six exons introduced a new translation stop site and might trigger nonsense mediated decay (NMD). The mRNA expression and the proportion of the seven CfTEP variant transcripts were examined in the gonad of scallops after bacterial challenge. The fragments containing the highly variable central region of UTEP were amplified by RT-PCR and a 100 positive clones were sequenced randomly. The expression profiles of the seven MEP variants were different and displayed the sex and bacteria dependent manner. In the blank, sea water and Listonella anguillarum challenged subgroups of male scallops, all the transcripts detected were CfTEP-G isoform. In the Micrococcus luteus challenged subgroup, the isoforms expressed and their proportions were CfTEP-F (54%), CfTEP-B (23%), CfTEP-A (10%), CfTEP-C (7%) and CfTEP-E (6%). However, in the gonad of female scallops, only CfTEP-A were found in blank and sea water challenged subgroups. After L anguillarum or M. luteus challenge, four and five isoforms were detected, respectively, with CfTEP-F isoform being the most one in the both subgroups. These results suggested that the evolution of TEP genes was very complex, and that the diverse CfTEP transcripts generated by alternative splicing played an important role as pattern recognition receptors in the innate immune defense of scallops. (C) 2009 Elsevier Ltd. All rights reserved.